Amberlite PWA8

PDF datasheet mirror for Amberlite PWA8 (Rohm & Haas). Verify with OEM before design.

Summary

Product Identification

AMBERLITE™ PWA8 Resin is an anion exchange resin designed for the removal of uranium from drinking water. It can also remove other anionic contaminants after cation exchange.

Properties

  • Matrix: Cross linked copolymer
  • Physical form: Clear white beads
  • Total exchange capacity: ≥ 1.6 eq/L
  • Moisture holding capacity: 56 – 64%
  • Shipping weight: 700 kg/m³ (45 lb/ft³)
  • Particle size:
    • Screen grading: 0.3 – 1.2 mm (16 – 50 mesh US Std Screens)
    • Fines content (< 0.300 mm): 2% maximum

Suggested Operating Conditions

Contact your Rohm and Haas representative for system design and application testing details.

  • Maximum operating temperature: 35°C (140°F)
  • Minimum bed depth: 600 mm (24 inches)
  • Typical service flow rate: 8 to 40 BV/h* (1 – 5 gpm/ft³)

* 1 BV (Bed Volume) = 1 m³ solution per m³ resin

Regenerant (for demineralization)

  • Regenerants: NaOH, NH₄OH, Na₂CO₃
  • Concentration: 2 – 4%
  • Minimum level: 130% of ionic load
  • Minimum contact time: 30 minutes

Commissioning and Limits of Use

  • AMBERLITE PWA8 resin is suitable for potable water applications after an initial commissioning rinse of 20 BV (140 gal/ft³) of water at 25°C (75°F).
  • Operating capacity depends on operating and feed water conditions.

Regulatory

  • Approved for use in Germany for potable water applications. Contact your Rohm and Haas representative for additional certification information.
  • Resin products are manufactured in ISO 9001 certified facilities.

Hydraulic Characteristics

Pressure drop and bed expansion data are provided in graphical form (Figures 1-4 in the original document). These figures show pressure drop as a function of flow rate and temperature, and bed expansion as a function of backwash flow rate and temperature.


Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.