Summary

Product identification

TRILITE® MC-10 is a UPS, SAC (Strong Acid Cation) gel-type ion exchange resin. It is a highly cross-linked product with a Sulfonic acid functional group. It is supplied in its Na⁺ form and can also be supplied in its H⁺ form.

Physical and Chemical Properties

  • Matrix: Polystyrene+DVB, Gel
  • Functional Group: Sulfonic acid
  • Ionic Form: Na⁺ (or H⁺)
  • Total Capacity: ≥ 2.20 eq/ℓ
  • Shipping Density: 850 g/ℓ
  • Moisture Retention: 38~44%
  • Particle Density: 1.32
  • Uniformity Coefficient: ≤ 1.1
  • Particle Size: 650±50 µm
  • Swelling Rate (Na⁺ → H⁺): 8%
  • Whole Beads: ≥ 95%

Recommended Operating Conditions

  • Operating Temperature: ≤ 120 °C
  • pH Range: 0~14
  • Bed Depth: 800 mm
  • Service Flow Rate: 5~120 m/h

Regeneration (for Na⁺ form)

  • Regenerant: HCl or H₂SO₄
  • Concentration:
    • HCl: 4~10%
    • H₂SO₄: 1~4%
  • Level: 50~200 g/ℓ
  • Flow Rate: 2~10 m/h
  • Rinse Requirement: 2~6 BV

Applications

TRILITE® MC-10 is used for softening, demineralization, and processes such as lysine production, sugar refining, and catalyst reactions. It can be used in Condensate Polishing Plants (CPP) in conjunction with TRILITE® MA-10.

Hydraulic Characteristics

Figures 1 and 2 show the backwash expansion of TRILITE® MC-10 (Na⁺ and H⁺ forms respectively) as a function of flow rate and temperature. Figures 3 and 4 show the pressure drop for TRILITE® MC-10 (Na⁺ and H⁺ forms respectively) as a function of flow rate and water temperature. See the official PDF for exact tabulated values.