Summary

Product identification

  • Product Name: SEPLITE® Monojet™SA8500U
  • Description: Uniform particle size, Gel type, Strong Base Anion (SBA) resin for single or mixed bed demineralization for Ultrapure Water applications.
  • Stock Code: 300487
  • Revision Date: 11.20.2020

Descriptions

SEPLITE® Monojet™SA8500U Ion Exchange Resin is a high-purity, high-capacity resin with uniform particle size designed specifically for the primary, second loop or polishing stage in ultrapure water preparation. This resin can be available in both OH⁻ form and Cl⁻ form, with the ionic conversion rate of OH⁻ form up to 95%. It is normally paired with SEPLITE® Monojet™SC7700U in H⁺ form in mixed bed systems.

Physical and Chemical Characteristics

  • Matrix Structure: Gel, Styrene-divinylbenzene
  • Functional group: Quaternary ammonium
  • Shipping form: OH⁻
  • Physical Appearance: White to yellow translucent spherical beads
  • Particle size (mm): 0.59 ± 0.05 mm
  • Particles <0.3mm: ≤0.5%
  • Particles ≥0.85mm: ≤1.0%
  • Moisture content (%): 55-65 (OH⁻ Form)
  • Total Capacity (eq/L): ≥1.1 (OH⁻ Form)
  • Bulk Density (g/L): 660-720
  • Density (g/L): 1080-1100
  • Whole beads count (%): ≥95
  • Uniformity coefficient: ≤1.1
  • Friability: Aver. min (g/bead) ≥200 (g/bead) / 350 / 95%
  • TOC leakage:* ≤5 ppb after 50 BV rinsing
  • Ionic conductivity as packaged:* ≤1 μS/cm

*Recommended influent water quality: Inlet Resistivity > 17.5 MΩ·cm

Recommended Operating Conditions

  • Maximum Operating Temperature:
    • 60℃ (single bed)
    • 60℃ (mixed bed)
  • Resin bed depth, min.:
    • 800 mm (single bed)
    • 450 mm (mixed bed)
  • Flow rate:
    • Service/fast rinse: 10-60 m/h
    • Regeneration: 4-10 m/h
  • Total Rinse: 2-5 BV
  • Regenerant: NaOH (4-8%)

Precautions

  • Resins should be stored in sealed containers or bags where the temperature is above 0℃ in dry conditions without exposure to direct sunlight.
  • Do not mix ion exchange resin with strong oxidizing agents; otherwise, it will cause violent reactions.
  • In case of eyes contact with resins, rinse eyes immediately with plenty of water and consult a specialist.
  • Material and samples must be disposed of according to local regulations.
  • Dry polymers will expand when become wetted and may cause an exothermic reaction.
  • Spilled materials may be slippery.