Datasheet summary
SEPLITE Monojet SC3100
PDF datasheet mirror for SEPLITE Monojet SC3100 (SUNRESIN). Verify with OEM before design.
Summary
Product Identification
- Product Name: SEPLITE® Monojet™SC3100
- Stock Code: 300487
- Description: Uniform particle size, Gel Strong acid cation resin for Industrial softening and demineralization applications.
Physical and Chemical Characteristics
- Matrix Structure: Gel, Styrene-divinylbenzene
- Functional group: Sulfonic acid
- Shipping form: Na⁺ (H⁺ is also available)
- Physical Appearance: Amber to dark brown translucent spherical beads
- Particle size:
- 0.60 ± 0.05 mm
- < 0.3 mm: ≤ 0.1%
- ≥ 0.85 mm: ≤ 3.0%
- Moisture content:
- 42-48% (Na⁺ Form)
- 50-55% (H⁺ Form)
- Total Capacity:
- ≥ 2.0 eq/L (Na⁺ Form)
- ≥ 1.8 eq/L (H⁺ Form)
- Bulk Density:
- 750-850 g/l (Na⁺ Form)
- 720-820 g/l (H⁺ Form)
- Density:
- 1260-1300 g/l (Na⁺ Form)
- 1170-1220 g/l (H⁺ Form)
- Whole beads count: ≥ 95%
- Uniformity coefficient: ≤ 1.1
Applications
- Industrial softening
- Industrial Demineralization
Recommended Operating Conditions
- Operating temp. (max): 120 °C
- Operating pH: 0-14
- Min. Bed depth: 800 mm
- Pressure drop (max): 280 kPa
- Backwash flow rate (max): 15-25 m/h (at 20°C)
- Backwash Bed expansion: Approx. 4 vol.% (at 20°C, per m/h)
- Backwash Freeboard: 60-100 vol.%
Regenerant (Counter-current regeneration)
- Regenerant: HCl / H₂SO₄ / NaCl
- Regeneration level: Approx. 50 / 80 / 60 g/l
- Regeneration concentration: 4-6% / 1.5-3% / 8-10% (wt.%)
- Contact time: 15-20 Minutes
- Regeneration flow rate: Approx. 5 / 10-20 m/h
- Rinse water requirement (slow/fast): Approx. 2-5 BV
Regenerant (Co-current regeneration)
- Regenerant: HCl / H₂SO₄ / NaCl
- Regeneration level: Approx. 100 / 150 / 120 g/l
- Regeneration concentration: 6-10% / 1.5-3% / 8-10% (wt.%)
- Contact time: 30-40 Minutes
- Regeneration flow rate: Approx. 5 m/h
- Rinse water requirement (slow/fast): Approx. 4-7 BV
Precautions
- Store resins in sealed containers or bags at temperatures above 0°C in dry conditions, away from direct sunlight.
- Avoid mixing ion exchange resin with strong oxidizing agents due to potential for violent reactions.
- In case of eye contact, rinse immediately with plenty of water and consult a specialist.
- Dispose of materials and samples according to local regulations.
- Dry polymers will expand when wetted, potentially causing an exothermic reaction.
- Spilled materials can be slippery.
Disclaimer: This extracted information may not include all figures, footnotes, or revisions from the original document. Contractual data must be verified against the specific OEM PDF revision used for the project.