Thermax Tulsion A-62 MP N

PDF datasheet mirror for Thermax Tulsion A-62 MP N (Thermax). Verify with OEM before design.

Summary

Product Identification

Product Name: Tulsion® A-62 MP N Type: PREMIUM GRADE MACROPOROUS STRONG BASE TYPE I ANION EXCHANGE RESIN

Tulsion® A-62 MP N is a premium grade, macro-porous, Type I strong base anion exchange resin with excellent physical and chemical stability. It is suitable for use across a wide range of pH and temperature conditions. A food-grade version for potable water treatment is also available. This resin is specifically effective at removing nitrate from water containing other anionic impurities and is highly resistant to organic fouling. Tulsion® A-62 MP N is NSF 61 certified and manufactured to achieve low VOCs. Pre-conditioning before use is recommended.

Typical Characteristics

  • Type: Macro-porous strong base anion exchange resin
  • Matrix structure: Cross linked polystyrene
  • Functional group: Quaternary Ammonium Type I
  • Physical form: Moist spherical beads
  • Ionic form: Chloride
  • Screen size USS (wet): 16-50
  • Particle size (minimum. 95%): 0.3 to 1.2 mm
  • Total exchange capacity (minimum): 1.0 meq/ml
  • Swelling (approx.): Cl⁻ to OH⁻ 21%
  • Moisture content: 52 ± 3%
  • Backwash settled density: 650 to 750 g/l
  • Maximum Operating temperature: 90 °C
  • pH range: 0 to 14
  • Solubility: Insoluble in all common solvents

Typical Operating Conditions

  • Maximum operating temperature: 90 °C
  • Resin bed depth minimum: 600 mm
  • Service flow rate: 5- 40 BV/Hr
  • Backwash flow rate (at 77 °F): 2-4 gpm/ft² (5 to 10 m³/Hr/m²)
  • Regenerant: NaCl
  • Regeneration level: 100 – 250 g NaCl/lit
  • Regenerant concentration: 6 – 10 % NaCl
  • Regeneration time: 15 – 60 minutes
  • Rinse flow rate:
    • Slow (at regeneration flow rate)
    • Fast (at service flow rate)
  • Rinse volume: 30 to 75 gal/ft³ (4 to 10 m³/m³)

Influent Limitations

  • Free chlorine: Not traceable
  • Turbidity: Less than 2 NTU
  • Iron and heavy metals: Less than 0.1 ppm

Testing & Pre-conditioning

Resin sampling and testing follow standard procedures: ASTMD-2187 and IS-7330, 1998. Pre-conditioning steps include:

  1. Backwashing the resin bed to expand it by 50%-60% for 10 minutes using process water.
  2. Soaking the resin in 2 BV of DI water for a minimum of 8 hours.
  3. Regenerating with a 6% NaCl solution (8 lb/cft) at a flow rate of 2 BV/hr.
  4. Rinsing with DM water until the effluent is chloride-free.
  5. Proceeding with NSF testing.

Packing

  • Super Sack: 1000 lit. / 35 cft
  • MS drums: 180 lit.
  • Fiber Drums: 7 cft
  • HDPE lined Bags: 25 lit. / 1 cft