Thermax Tulsion MBNR 1154

PDF datasheet mirror for Thermax Tulsion MBNR 1154 (Thermax). Verify with OEM before design.

Summary

Product identification

Product Name: TULSION® MBNR-1154 Description: Premium grade mixed ion exchange resin for treatment of primary circuit water in PWR nuclear power operation. Nuclear grade mixed bed resin.

Operating limits

  • Temperature stability: 120°C (cation component), 80°C (anion component)
  • pH range: 0 to 14

Feed water limitations

  • Free Chlorine: Not traceable
  • Turbidity: < 2 NTU
  • Iron & heavy metals: < 0.1 ppm

Typical Characteristics (TULSION MBNR-1154)

The resin is a mixture of TULSION® T-46 (cation) and TULSION® A-333 (anion).

  • Type:
    • Cation: Strong Acid Cation Exchange Resin
    • Anion: Strong base anion exchange resin
  • Volume ratio: 1 (cation) : 1.5 (anion)
  • Matrix structure: Cross linked polystyrene
  • Functional group:
    • Cation: Sulphonic acid
    • Anion: Quaternary Ammonium Type I
  • Physical form: Amber color moist beads
  • Ionic form supplied:
    • Cation: Lithium (Li⁺)
    • Anion: Hydroxide (OH⁻)
  • Uniform coefficient: 1.4 max
  • Total exchange capacity:
    • Cation: 1.75 meq/ml min (of 99% in Li form)
    • Anion: 1.1 meq/ml min (of 90% in OH form)
  • Moisture content:
    • Cation: 50 ± 3%
    • Anion: 62 ± 3%
  • Bead strength: >350 g/bead
  • Metals, dry resin (ppm max.): Na, Mg, Fe, Ca, Al -50; Pb & Cu - 10
  • Chloride contents: <0.5 %
  • OH conversion: >90%
  • Backwash settled density: Approx. 700 to 750 gm/liter

Testing

Sampling and testing are performed as per ASTM D-2187 and IS-7330 (1998).

Packing

  • Super Sack: 1000 liters / 35 cft
  • MS drums: 180 liters
  • Fiber Drums: 7 cft
  • HDPE lined Bags: 25 liters / 1 cft