Thermax Tulsion T-42 NA N

PDF datasheet mirror for Thermax Tulsion T-42 NA N (Thermax). Verify with OEM before design.

Summary

Product identification

  • Product Name: TULSION® T-42 Na N
  • Type: Premium Grade Strong Acid Cation Exchange Resin
  • Description: Gel type cation exchange resin with Sulphonic acid as functional group. Excellent resistance to oxidizing agents with high operating capacity. Supplied in moist spherical beads, in Sodium form, with excellent physical and chemical characteristics. Used for industrial and domestic softening at relatively low regeneration cost. NSF grade resin, conditioned to achieve low VOCs.

Typical Characteristics

  • Appearance: Amber color beads
  • Functional group: Sulphonic
  • Physical form: Moist Spherical Beads
  • Ionic form: Sodium
  • Screen Size USS (wet): 16 to 50
  • Particle size (95% min): 0.3 to 1.2 mm
  • Total Exchange Capacity (minimum): 2.0 meq/ml
  • Moisture content: 45 ± 3%
  • Reversible swelling (%): Na⁺ to H⁺: 7
  • pH range: 0 to 14
  • Solubility: Insoluble in all common solvents
  • Backwash settled density (Na⁺): 810 to 850 g / l (52 - 54 lbs/cft)
  • Temperature stability (max.): 140°C

Suggested Operating Parameters

  • Maximum operating temperature (Na⁺ form): 140°C
  • Resin bed depth (minimum): 600 mm
  • Maximum service flow: 120 m³/hr/m³ (15 gpm/ft³)
  • Backwash expansion space: 40 to 75%
  • Backwash flow rate for 40-70% expansion: 9 to 25 m³/hr/m³ (4 to 10 gpm/ft²)
  • Regenerant: NaCl
  • Regeneration level: 60 - 160 g NaCl / l (3.7 to 1.0 lbs HCl/ft³)
  • Regenerant concentration: 5.0 - 15.0% NaCl
  • Regenerant flow rate: 2 to 16 m³/hr/m³ (0.25 to 2 gpm/ft³)
  • Regeneration time: 30 to 60 min
  • Rinse flow rate (Slow): At regeneration flow rate
  • Rinse flow rate (Fast): At service flow rate
  • Rinse volume: 3 to 5 m³/m³

Influent Limitation

  • Free chlorine: Not traceable
  • Turbidity: Less than 2 NTU
  • Iron and heavy metals: Less than 0.1 ppm

Pre-conditioning of Resin

  1. Load resin in the column and carry out backwash with process water to expand resin bed at least 50%-60% for 10 minutes. Allow resin to settle and drain water from the column up to resin bed level.
  2. Fill resin column with 2 BV DI water and soak it for minimum 12 hrs.
  3. Drain water up to resin bed level.
  4. Carry out brine regeneration using 8 lb/cft NaCl as 6% solution at 2 BV/hr flow rate. Rinse with DM water until effluent is chloride free.

Testing

Sampling and testing of ion exchange resins are done as per standard testing procedures, namely ASTM D-2187 and IS-7330, 1998.

Packing

  • Super Sack: 1000 lit. (35 cft)
  • MS drums: 180 lit. (7 cft)
  • Fiber Drums: 7 cft
  • HDPE lined Bags: 25 lit. (1 cft)