Datasheet summary
Thermax Tulsion T-52 H UPS
PDF datasheet mirror for Thermax Tulsion T-52 H UPS (Thermax). Verify with OEM before design.
Summary
Product Identification
- Product Name: Tulsion® T-52 UPS
- Product Type: Gel type, strong acid cation exchange resin
- Key Features: Excellent resistance to oxidizing agents, high operating capacity, supplied in moist spherical beads in hydrogen form with minimum impurities to meet nuclear industry specifications. Can be used with Tulsion® A-23 UPS in mixed bed units.
Typical Characteristics
- Matrix Structure: Polystyrene Copolymer
- Functional Group: Sulphonic
- Physical Form: Moist Spherical Beads
- Ionic Form: Hydrogen
- Screen Size USS (wet): 16 to 40
- Particle Size (95% min): 0.4 to 1.2 mm
- Uniformity Coefficient: 1.4 max
- Total Exchange Capacity: 1.9 meq/ml (min)
- Moisture Content: 48 ± 3%
- Swelling (approx): Sodium to Hydrogen : 6%
- pH Range: 0 to 14
- Solubility: Insoluble in all common solvents
Operating Limits
- Maximum Operating Temperature: 120°C
- Resin Bed Depth (minimum): 800 mm
- Maximum Service Flow: 120 m³/hr/m³
- Backwash Expansion Space: 40 – 75%
- Backwash Flow Rate (for 40-70% expansion): 9 – 20 m³/hr/m³
Regeneration
- Regenerant: HCl or H₂SO₄
- Regeneration Level:
- 30 to 160 g HCl / lit
- 40 to 250 g H₂SO₄ / lit
- Regenerant Concentration:
- 3 – 5% HCl
- 1.5 – 4% H₂SO₄
- Regeneration Flow Rate: 2 to 16 m³/hr/m³
- Regeneration Time: 30 to 60 min
- Rinse Flow Rate:
- Slow: At regeneration flow rate
- Fast: At service flow rate
Influent Limitations
- Free Chlorine: Not traceable
- Turbidity: Less than 2 NTU
- Iron and Heavy Metals: Less than 0.1 ppm
Testing
Sampling and testing are performed according to ASTMD-2187 and IS-7330, 1998.
Packing
- Super Sack: 1000 lit. / 35 cft
- MS drums: 180 lit.
- Fiber Drums: 7 cft
- HDPE lined Bags: 25 lit. / 1 cft