Back to Thermax
Thermax logo

Datasheet summary

Thermax Tulson T-56 H UPS

PDF datasheet mirror for Thermax Tulson T-56 H UPS (Thermax). Verify with OEM before design.

Summary

Product identification

T-56 H UPS is a premium grade, gel-type, strong acid cation exchange resin in hydrogen form. It is a polystyrene copolymer with a sulfonic functional group.

Typical Characteristics

  • Matrix structure: Polystyrene Copolymer
  • Functional group: Sulphonic
  • Physical form: Moist Spherical Beads
  • Ionic form: Hydrogen
  • Screen Size USS (wet): 16 to 40
  • Particle size (95% min): 0.4 to 1.2 mm
  • Uniformity Coefficient: 1.3 to 1.4
  • Total Exchange Capacity: 2.0 meq/ml (min)
  • Moisture content: 48 ± 3%
  • Swelling (approx): Sodium to Hydrogen : 6%
  • pH range: 0 to 14
  • Solubility: Insoluble in all common solvents

Testing is performed according to ASTMD-2187 and IS-7330, 1998.

Operating limits

  • Maximum operating temperature: 120°C
  • Resin bed depth (minimum): 800 mm
  • Maximum service flow: 120 m³/hr/m³
  • Backwash expansion space: 40 – 75%
  • Backwash flow rate for 40-70% expansion: 9 – 20 m³/hr/m³

Regeneration

  • Regenerant: HCl or H₂SO₄
  • Regeneration level: 30 to 160 g HCl / lit or 40 to 250 g H₂SO₄ / lit
  • Regenerant concentration: 3 – 5% HCl or 1.5 – 4% H₂SO₄
  • Regeneration flow rate: 2 to 16 m³/hr/m³
  • Regeneration time: 30 to 60 min
  • Rinse flow rate:
    • Slow: At regeneration flow rate
    • Fast: At service flow rate

Feed water limitations

  • Free chlorine: Not traceable
  • Turbidity: Less than 2 NTU
  • Iron and heavy metals: Less than 0.1 ppm

Packaging

Available in Super Sack (1000 lit / 35 cft), MS drums (180 lit), Fiber Drums (7 cft), and HDPE Lined Bags (25 lit / 1 cft).

Disclaimer: The data included herein are based on test information obtained by Thermax Limited. These data are believed to be reliable, but do not imply any warranty or performance guarantee. Tolerances for characteristics are per BIS/ASTM. We recommend that the user should determine the performance of the product by testing on his own processing equipment. For handling, safety and storage requirements please refer to the individual Material Safety Data Sheets. Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror