Datasheet summary
ICT-5
Engineering summary from PDF text extraction for ICT-5. Verify every value with the OEM datasheet.
Summary
Product identification
Ozone generator: ICT 05-10
Operating limits
- Ozone production:
- Concentration, max: 240 g/Nm³
- Feed gas (Oxygen):
- Purity: 99% (max dew point -60 °C / -140 °F)
- Inlet pressure: 2 – 4 bar g (29.0 - 58.0 psig)
- Internal pressure: 0.8 – 1.2 bar g (11.6 - 17.4 psig)
- Cooling water:
- Quality: Fresh, filtered & clean
- Inlet pressure: 1 – 5 bar g (14.5 - 72.5 psig)
- Temperature: 5 -12 °C (41- 53.6 °F)
- Flow: 0.5 l/min
Electrical
- Voltage rating: 230 VAC, 50 Hz (Optional: 115 VAC, 60 Hz)
- Power consumption, max: 125 W
Mechanical / hydraulic
- Cabinet: Stainless steel
- Connections:
- O₂ in: 8 mm, push in
- O₃ out: 8 mm, tube fitting
- Cooling water in: 8 mm, push in
- Cooling water out: 8 mm, push in
- Dimensions (H x W x D): 300 x 200 x 155 mm (11.8 x 7.9 x 6.1 in)
- Weight: 8.5 kg (18.7 lb)
- IP class: 64
Specifications by model
| Model | Nominal O₃ prod. [g/h] | O₃ concentration [g/Nm³] | O₂ flow [g/Nm³] | O₂ pressure, max [g/Nm³] |
|---|---|---|---|---|
| ICT-5 | 0-5 | 135 | 0.6 | 1.2 / 17.4 |
| ICT-5LAB | 0-5 | 135 | 0.6 | 1.2 / 17.4 |
| ICT-10 | 0-10 | 135 | 2.5 | 1.2 / 17.4 |
Advantages
- Low energy consumption
- High ozone concentration
- Very low noise level
- Compact design
- Easy to maintain
- Alarm signal output (relay)
- 4-20 mA analogue input
Disclaimer: This summary is an extraction from a PDF datasheet and may not include all figures, footnotes, or revisions. Contractual data must match the official OEM PDF revision used for the project.
Official datasheet (PDF)
Index context
-
Category hub: https://www.lenntech.com/products/ozone-generator.htm
-
Brand line: https://www.lenntech.com/products/ozonetech.htm