Back to Ozonetech Ozone Generators
Ozonetech logo

Datasheet summary

ICT-5

Engineering summary from PDF text extraction for ICT-5. Verify every value with the OEM datasheet.

Summary

Product identification

Ozone generator: ICT 05-10

Operating limits

  • Ozone production:
    • Concentration, max: 240 g/Nm³
  • Feed gas (Oxygen):
    • Purity: 99% (max dew point -60 °C / -140 °F)
    • Inlet pressure: 2 – 4 bar g (29.0 - 58.0 psig)
    • Internal pressure: 0.8 – 1.2 bar g (11.6 - 17.4 psig)
  • Cooling water:
    • Quality: Fresh, filtered & clean
    • Inlet pressure: 1 – 5 bar g (14.5 - 72.5 psig)
    • Temperature: 5 -12 °C (41- 53.6 °F)
    • Flow: 0.5 l/min

Electrical

  • Voltage rating: 230 VAC, 50 Hz (Optional: 115 VAC, 60 Hz)
  • Power consumption, max: 125 W

Mechanical / hydraulic

  • Cabinet: Stainless steel
  • Connections:
    • O₂ in: 8 mm, push in
    • O₃ out: 8 mm, tube fitting
    • Cooling water in: 8 mm, push in
    • Cooling water out: 8 mm, push in
  • Dimensions (H x W x D): 300 x 200 x 155 mm (11.8 x 7.9 x 6.1 in)
  • Weight: 8.5 kg (18.7 lb)
  • IP class: 64

Specifications by model

ModelNominal O₃ prod. [g/h]O₃ concentration [g/Nm³]O₂ flow [g/Nm³]O₂ pressure, max [g/Nm³]
ICT-50-51350.61.2 / 17.4
ICT-5LAB0-51350.61.2 / 17.4
ICT-100-101352.51.2 / 17.4

Advantages

  • Low energy consumption
  • High ozone concentration
  • Very low noise level
  • Compact design
  • Easy to maintain
  • Alarm signal output (relay)
  • 4-20 mA analogue input

Disclaimer: This summary is an extraction from a PDF datasheet and may not include all figures, footnotes, or revisions. Contractual data must match the official OEM PDF revision used for the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Index context

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.