Back to Ozonia Ozone Generators
Ozonia logo

Datasheet summary

Ozonia CFV

Engineering summary from PDF text extraction for Ozonia CFV. Verify every value with the OEM datasheet.

Summary

Product identification

The ozonia® CFV range of ozone generators incorporates SUEZ’s Advanced Technology (AT) dielectric segments and IGBT power supply units. These are integrated packages designed for medium-sized ozone applications and are suitable for remote service in drinking water plants.

Applications

  • Drinking water
  • Wastewater
  • Process water
  • Oxidation and advanced oxidation

Main Features

  • The industry’s most robust electrodes
  • Fused dielectrics for high availability
  • Manufacturing facilities in Europe, China, and North America
  • Globally adaptable standards
  • Industry-leading engineering capabilities
  • Reliability and long service life

Operating limits

  • Ambient temperature: +5 to 40°C
  • Design altitude: < 1,000 m a.s.l.
  • Humidity: RH < 65% (yearly average)

Electrical

  • Voltage: 3 x 360 to 495 VAC
  • Frequency: 50 / 60 Hz

Technical features

ModelFeed gas: OxygenFeed gas: Air
Max production O₃ (lb/d)Max production O₃ (lb/d)
Max production O₃ (kg/h)Max production O₃ (kg/h)
Concentration O₃ (%-wt)Concentration O₃ (%-wt)
ozonia® CFV-02100.5 lb/d, 1.9 kg/h, 6 to 14 %-wt48.1 lb/d, 0.9 kg/h, 1 to 5 %-wt
ozonia® CFV-03148.2 lb/d, 2.8 kg/h, 6 to 14 %-wt72.5 lb/d, 1.4 kg/h, 1 to 5 %-wt
ozonia® CFV-04195.8 lb/d, 3.7 kg/h, 6 to 14 %-wt94.2 lb/d, 1.8 kg/h, 1 to 5 %-wt
ozonia® CFV-05301.6 lb/d, 5.7 kg/h, 6 to 14 %-wt139.2 lb/d, 2.6 kg/h, 1 to 5 %-wt
ozonia® CFV-10597.9 lb/d, 11.3 kg/h, 6 to 14 %-wt278.8 lb/d, 5.3 kg/h, 1 to 5 %-wt
ozonia® CFV-15904.8 lb/d, 17.1 kg/h, 6 to 14 %-wt421.7 lb/d, 8.0 kg/h, 1 to 5 %-wt
ozonia® CFV-201,153.5 lb/d, 21.8 kg/h, 6 to 14 %-wt537.6 lb/d, 10.2 kg/h, 1 to 5 %-wt
ozonia® CFV-301,899.5 lb/d, 35.9 kg/h, 6 to 14 %-wt-

Note: Data for ozonia® CFV-30 with air feed gas is not specified in the extract.

Mechanical / hydraulic

ModelDimensions (L x H x W) inchDimensions (L x H x W) mmWeight lbWeight kg
ozonia® CFV-0278.74 x 78.74 x 45.272,000 x 2,000 x 1,150~ 1653~750
ozonia® CFV-0378.74 x 78.74 x 45.272,000 x 2,000 x 1,150~1874~ 850
ozonia® CFV-0478.74 x 78.74 x 45.272,000 x 2,000 x 1,150~ 2,094~ 950
ozonia® CFV-0598.42 x 78.74 x 45.272,500 x 2,000 x 1,500~ 4,409~ 2,000
ozonia® CFV-10114.17 x 78.74 x 74.802,900 x 2,000 x 1,900~ 4,519~ 2,050
ozonia® CFV-15114.17 x 78.74 x 74.802,900 x 2,000 x 1,900~ 5,511~ 2,500
ozonia® CFV-20114.17 x 78.74 x 74.802,900 x 2,000 x 1,900~ 6,614~ 3,000
ozonia® CFV-30 Vessel135.82 x 74.80 x 61.023,450 x 1,900 x 1,550~ 8,377~ 3,800
ozonia® CFV-30 PSU-Cubicle118.11 x 78.74 x 39.373,000 x 2,000 x 1,000~ 4,960~ 2,250

Note: Dimensions and weights are approximate and may vary.

Options

  • Profinet (Siemens PLC)
  • Modbus TCP (Allen Bradley PLC)
  • Modbus TCP (Schneider PLC)
  • Power-cut and lightning protection
  • Power analyser

Remote control and alarms

  • Supply ON/OFF
  • Enable REMOTE
  • Alarm RESET
  • Emergency STOP
  • Gasflow ON
  • Collective ALARM
  • Setpoint current (4-20 mA)

Disclaimer: This summary is based on an extraction from a datasheet and may not include all figures, footnotes, or revisions. Contractual data must be confirmed against the official OEM PDF revision used for the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Index context

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.