Summary
Product identification
Ozonia RB Destruct Unit
The Ozonia RB units are thermal ozone destruct units with heat recuperation designed to decompose residual ozone in vent gases before release into the atmosphere.
Operating limits
- Ozone outlet concentration: < 0.1 ppm
- Operating pressure: ±0.1 barg
- Standard conditions: at standard conditions
Feed water
The units treat vent gases containing trace levels of un-reacted ozone.
Product water
Treated gas with ozone content well below safety limits (< 0.1 ppm).
Technical Features
- Design standards: EN, IEC, ISO, SN
- Protection class: IP 42
- Conformity: CE
- Connection data: 3 x 400 V ±10%, 50 Hz
Materials
- VOD: Stainless steel
- Skid: Galvanised mild steel
- Fan: Stainless steel and aluminium
- Insulation: Mineral wool
- Cover sheet: Galvanised mild steel
Remote control and alarms
- REMOTE enable
- Unit running
- Temperature lower than max. alarm value
- Temperature higher than lower alarm value
- Over protection switch tripped
- All miniature circuit breakers are ON
- Unit ON/OFF
Model specifications
| Model | Mass flow (kg/h) | Ozone level inlet (wt%) | Ozone level outlet (ppm) | Operating pressure (barg) | Electrical rating (kW) | Dimensions L x H x W (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| ozonia® RB-10 | 100 (air), 110 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 6.7 | 4330 x 1740 x 800 | 720 |
| ozonia® RB-13 | 125 (air), 140 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 7.7 | 4330 x 1740 x 800 | 730 |
| ozonia® RB-16 | 160 (air), 175 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 9.2 | 4370 x 1840 x 900 | 1030 |
| ozonia® RB-20 | 200 (air), 220 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 10.7 | 4370 x 1840 x 900 | 1050 |
| ozonia® RB-25 | 250 (air), 275 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 12.7 | 4370 x 1840 x 900 | 1070 |
| ozonia® RB-32 | 315 (air), 350 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 15.7 | 4970 x 1915 x 1000 | 1250 |
| ozonia® RB-40 | 400 (air), 440 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 18.7 | 4970 x 1915 x 1000 | 1280 |
| ozonia® RB-50 | 500 (air), 550 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 22.7 | 5050 x 1915 x 1000 | 1600 |
| ozonia® RB-63 | 630 (air), 700 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 27.7 | 5050 x 1915 x 1000 | 1670 |
| ozonia® RB-80 | 800 (air), 880 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 38.5 | 5540 x 2180 x 1100 | 1780 |
| ozonia® RB-100 | 1000 (air), 1100 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 46.5 | 5540 x 2180 x 1100 | 1850 |
| ozonia® RB-125 | 1250 (air), 1400 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 57.5 | 6090 x 2355 x 1200 | 2700 |
| ozonia® RB-160 | 1600 (air), 1750 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 72.5 | 6090 x 2355 x 1200 | 2800 |
| ozonia® RB-200 | 2000 (air), 2200 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 91.0 | 6380 x 2605 x 1300 | 3100 |
| ozonia® RB-250 | 2500 (air), 2750 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 115.0 | 6380 x 2605 x 1300 | 3300 |
| ozonia® RB-315 | 3150 (air), 3500 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 150.0 | 6580 x 2805 x 1300 | 4000 |
| ozonia® RB-400 | 4000 (air), 4400 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 180.0 | 7180 x 2905 x 1400 | 4900 |
| ozonia® RB-500 | 5500 (air), 5500 (oxygen) | < 1.5 | < 0.1 | ±0.1 | 230.0 | 7280 x 3105 x 1500 | 5800 |
Note: Mass flow values are provided for both air and oxygen.
Product highlights
- Very high ozone destruct efficiency
- Low power consumption
- Long service life
- Virtually maintenance-free
- Easy integration
- Compact dimensions
- High product integrity
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Index context
-
Category hub: https://www.lenntech.com/products/ozone-generator.htm
-
Brand line: https://www.lenntech.com/products/ozonia.htm
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.