Back to Pacific Ozone Generators
Pacific Ozone logo

Datasheet summary

Pacific Large SGA 90 - 240 g/h

Engineering summary from PDF text extraction for Pacific Large SGA 90 - 240 g/h. Verify every value with the OEM datasheet.

Summary

Product identification

The Large SGA Series of integrated ozone/oxygen systems combines air-cooled ozone generation with onboard oxygen concentration in a compact, stainless steel housing. Models include Large SGA53/63/64. The series is part of a family of integrated ozone oxygen systems that include the standard SGA Series with ozone production capability to 3.2 lbs./day.

Features

  • Stainless Steel Floor Mount Enclosure
  • Air-Cooled Ceramic and Titanium Reactor Cell
  • Onboard Oxygen Concentrator
  • 0.01 Micron Filter/Regulator with Auto Drain
  • Over-Temperature Protection

Controls

  • 4-20mA or 0-10VDC Input
  • Variable Output Control
  • Feed Gas Flow Control
  • Remote On/Off Control
  • Power Supply Control Signal Reference Meter
  • Reactor Pressure Control
  • Reactor Pressure Gauge
  • Air Input Pressure Gauge
  • Remote Lockout

Technical Specifications

Model/Part NumberMax. Ozone Production lbs./day (grams/hour)Max. Ozone Concentration % weightMax. Reactor Pressure psig (bar)Feed Gas Flow Range scfh (lpm)Power Consumption wattsCompressed Air Flow scfm (lpm)Compressed Air Inlet FittingOzone Outlet Fitting*Dimensions (HxWxD) inches (mm)Weight lbs (kg)
SGA43/R-SGA432 (230V)4.8 (90)8%12 (0.8)10-80 (5-38)1100480 (13592)1/2” fnpt (12.7 mm)1/2” (12.7 mm)30.5x35.1x29.4 (774x892x746)220 (100)
SGA44/R-SGA442 (230V)6.3 (120)8%12 (0.8)10-80 (5-38)1200480 (13592)1/2” fnpt (12.7 mm)1/2” (12.7 mm)30.5x35.1x29.4 (774x892x746)230 (104)
SGA53/R-SGA532 (230V)7.1 (135)8%12 (0.8)20-120 (9-57)2190720 (20388)1/2” fnpt (12.7 mm)1/2” (12.7 mm)53.7x35.1x29.4 (1364x892x746)330 (150)
SGA63/R-SGA632 (230V)9.5 (180)8%12 (0.8)20-160 (9-76)2920960 (27184)1/2” fnpt (12.7 mm)1/2” (12.7 mm)53.7x35.1x29.4 (1364x892x746)375 (170)
SGA64/R-SGA642 (230V)12.7 (240)8%12 (0.8)20-160 (9-76)3320960 (27184)1/2” fnpt (12.7 mm)1/2” (12.7 mm)53.7x35.1x29.4 (1364x892x746)460 (209)

*Compression fitting.

Operational Requirements

Model/Part NumberCompressed Air Flow scfm (lpm)Compressed Air Pressure psig (bar)Electrical Requirement
SGA43/R-SGA432 (230V)24 (680)40 (2.76)230V 50/60Hz 1 phase 20A Circuit
SGA44/R-SGA442 (230V)24 (680)40 (2.76)230V 50/60Hz 1 phase 20A Circuit
SGA53/R-SGA532 (230V)36 (1019)40 (2.76)230V 50/60Hz 1 phase 20A Circuit
SGA63/R-SGA632 (230V)48 (1359)40 (2.76)230V 50/60Hz 1 phase 20A Circuit
SGA64/R-SGA642 (230V)48 (1359)40 (2.76)230V 50/60Hz 1 phase 20A Circuit

The Large SGA Series is designed to operate with high-quality plant air provided from the facility. Stand-alone air compressor packages are also available if plant air is unavailable or insufficient.


Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.