Pacific SGA-series 12 - 60 g/h s

Engineering summary from PDF text extraction for Pacific SGA-series 12 - 60 g/h s. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Product Line: SGA Series Integrated Ozone/Oxygen Systems
  • Models: SGA11, SGA21, SGA22, SGA23, SGA24 (with voltage variations R-SGAxx1 for 115V, R-SGAxx2 for 230V)

Features

  • Compact, wall-mountable stainless steel housing
  • Air-cooled ceramic and titanium reactor cell
  • Onboard oxygen concentrator
  • 0.01 Micron Filter/Regulator with Auto Drain
  • Over-Temperature Protection
  • Feed Gas Flow Switch
  • Patented Floating Plate Technology™ for ozone generation

Controls

  • 0-100% variable power control
  • Feed gas control
  • Inlet air pressure and reactor back-pressure gauges
  • Power supply feedback reference meter
  • LED ozone production indicator
  • 4-20mA or 0-10VDC input signal for 0-100% variable ozone concentration control
  • Remote On/Off Control

Technical Specifications

Model/Part NumberMax. Ozone Production (lbs./day) (grams/hour)Max. Ozone Concentration (% weight)Max. Reactor Pressure (psig (bar))Feed Gas Flow Range (scfh (lpm))Power Consumption (watts)Air CoolingCompressed Air Inlet FittingOzone Outlet Fitting*Dimensions (HxWxD) (inches (mm))Weight (lbs (kg))
SGA11/R-SGA111 (115V)0.6 (12)5%12 (0.8)7-20 (3.3-9.4)300240 (6796)1/4” fnpt (6.35 mm)1/4” (6.35 mm)22.3x19.0x11.1 (566x483x282)70 (32)
SGA11/R-SGA112 (230V)0.6 (12)5%12 (0.8)7-20 (3.3-9.4)300240 (6796)1/4” fnpt (6.35 mm)1/4” (6.35 mm)22.3x19.0x11.1 (566x483x282)70 (32)
SGA21/R-SGA211 (115V)1.0 (18)6%12 (0.8)7-20 (3.3-9.4)300240 (6796)1/4” fnpt (6.35 mm)1/4” (6.35 mm)22.3x19.0x11.1 (566x483x282)75 (34)
SGA21/R-SGA212 (230V)1.0 (18)6%12 (0.8)7-20 (3.3-9.4)300240 (6796)1/4” fnpt (6.35 mm)1/4” (6.35 mm)22.3x19.0x11.1 (566x483x282)75 (34)
SGA22/R-SGA221 (115V)1.6 (30)8%12 (0.8)7-20 (3.3-9.4)450240 (6796)1/4” fnpt (6.35 mm)1/4” (6.35 mm)22.3x19.0x11.1 (566x483x282)85 (39)
SGA22/R-SGA222 (230V)1.6 (30)8%12 (0.8)7-20 (3.3-9.4)450240 (6796)1/4” fnpt (6.35 mm)1/4” (6.35 mm)22.3x19.0x11.1 (566x483x282)85 (39)
SGA23/R-SGA231 (115V)2.4 (45)8%12 (0.8)10-40 (4.7-18.9)525240 (6796)1/4” fnpt (6.35 mm)1/4” (6.35 mm)22.3x27.5x11.1 (566x699x282)110 (50)
SGA23/R-SGA232 (230V)2.4 (45)8%12 (0.8)10-40 (4.7-18.9)525240 (6796)1/4” fnpt (6.35 mm)1/4” (6.35 mm)22.3x27.5x11.1 (566x699x282)110 (50)
SGA24/R-SGA242 (230V)3.2 (60)8%12 (0.8)10-40 (4.7-18.9)580240 (6796)1/4” fnpt (6.35 mm)1/4” (6.35 mm)22.3x27.5x11.1 (566x699x282)115 (52)

Operational Requirements

Model/Part NumberCompressed Air Flow (scfm (lpm))Compressed Air Pressure (psig (bar))Electrical Requirement
SGA11/R-SGA111 (115V)6 (170)30 (2.07)115V 60Hz, 1 phase 15A Circuit
SGA11/R-SGA112 (230V)6 (170)30 (2.07)230V 50/60Hz, 1 phase 15A Circuit
SGA21/R-SGA211 (115V)6 (170)30 (2.07)115V 60Hz, 1 phase 15A Circuit
SGA21/R-SGA212 (230V)6 (170)30 (2.07)230V 50/60Hz, 1 phase 15A Circuit
SGA22/R-SGA221 (115V)6 (170)30 (2.07)115V 60Hz, 1 phase 15A Circuit
SGA22/R-SGA222 (230V)6 (170)30 (2.07)230V 50/60Hz, 1 phase 15A Circuit
SGA23/R-SGA231 (115V)12 (340)30 (2.07)115V 60Hz, 1 phase 15A Circuit
SGA23/R-SGA232 (230V)12 (340)30 (2.07)230V 50/60Hz, 1 phase 15A Circuit
SGA24/R-SGA242 (230V)12 (340)30 (2.07)230V 50/60Hz, 1 phase 15A Circuit