Datasheet summary
Pacific Summit-series 12 - 60 g/h
Engineering summary from PDF text extraction for Pacific Summit-series 12 - 60 g/h. Verify every value with the OEM datasheet.
Summary
Product Identification
The Summit Series are integrated ozone systems designed to eliminate the complexity of combining feed gas preparation, ozone generation, mass transfer, and process control. These systems are offered in sanitary, splash-resistant, stainless steel skid-based packages.
Applications
- Beverage industry
- Bottled water
- Food processing
- Industrial water treatment
Features
- Modular Ozone Chassis Design
- Stainless Steel Frame and Enclosures
- Air-Cooled Ceramic and Titanium Reactor Cell
- Over-Temperature Protection
- Optional Degas Separator
- Redundant Backflow Prevention
- Enhanced Mass Transfer™ ozone injection and off-gas destruction system
- Standard stainless steel mass transfer vessels available in 50 and 150 gallons; larger vessels are also available.
- Tank-less Fat Pipe mass transfer system available for continuous operation.
Standard Features
- Remote On/Off ozone control
- Remote Lockout
- PID Controller
- One or two channels of dissolved ozone detection
- Ambient Ozone Detector with safety interlock (alarms at OSHA long-term exposure limit and shuts down production if OSHA short-term exposure limit is exceeded)
PLUS Option Package
- Degas Separator: Reduces ozone off-gas by collecting undissolved ozone and shunting it to the system ozone destruct.
Additional Options
- Process pumps
- Additional process inputs
- DirectDrive™ Control System
- Optional air compressor packages
Controls
- 4-20mA or 0-10VDC Input
- Variable Output Control
- Programmable PID Controller
- Dissolved Ozone Sensor
- Ambient Ozone Detector with Safety Interlock
- Remote On/Off Control
- Reactor Pressure Control
- Feed Gas Flow Control
Operating Limits
Ozone Production and Performance
| Model/Part Number | Ozone Generator Model | Max. Ozone Production (lbs/day) | Performance (at 2 ppm O₃) (gpm) | Power Consumption (watts) |
|---|---|---|---|---|
| Summit A11 | SGA11 | 0.6 | 25 | 2500 |
| Summit A21 | SGA21 | 1.0 | 40 | 2500 |
| Summit A22 | SGA22 | 1.6 | 65 | 2500 |
| Summit A23 | SGA23 | 2.4 | 100 | 2500 |
| Summit A24 | SGA24 | 3.2 | 130 | 2500 |
| Summit C11 | SGC11 | 0.5 | 20 | 2500 |
| Summit C21 | SGC21 | 0.8 | 35 | 2500 |
| Summit C22 | SGC22 | 1.3 | 55 | 2500 |
Custom, high-output systems producing up to 10 pounds of ozone per day are also available.
Ozone Destruct System
- Catalyst: Manganese Dioxide/Copper Oxide
- Destruct Potential: Sized to application requirements
- Operating Temperature: 130º-140º F (54º-60º C), electronically controlled
Operational Requirements
| Model | Compressed Air Flow (scfm) | Compressed Air Pressure (psig) | Water Pressure (psig) | Electrical Requirement |
|---|---|---|---|---|
| Summit A11 | 6 | 30 | 20-30 | 230V 50/60Hz, 1 phase 30A Circuit |
| Summit A21 | 6 | 30 | 20-30 | 230V 50/60Hz, 1 phase 30A Circuit |
| Summit A22 | 6 | 30 | 20-30 | 230V 50/60Hz, 1 phase 30A Circuit |
| Summit A23 | 12 | 30 | 20-30 | 230V 50/60Hz, 1 phase 30A Circuit |
| Summit A24 | 12 | 30 | 20-30 | 230V 50/60Hz, 1 phase 30A Circuit |
| Summit C11, C21, C22 | N/A* | N/A* | 20-30 | 230V 50/60Hz, 1 phase 30A Circuit |
*Not Applicable - All Summit C-Line models include onboard air compression.
Mechanical / Hydraulic
Mass Transfer System Components
- Injection Pump: Stainless steel, sized to system requirements
- Venturi: MIC natural Kynar injector
- Back Flow Prevention: Stainless steel check valve and proprietary backflow prevention system
- Mass Transfer Vessel: Standard options include Fat Pipe, 50 gal., or 150 gal. Larger vessels available.
- Inlet/Outlet: 1.5” stainless steel sanitary connections. Larger fittings available.
- Pump Protection: Tank level switch, interlocked.
- Assembly: Stainless steel frame.
Dimensions
Summit Series with 50 Gallon Mass Transfer Vessel
- Overall (L x W x H): 762 x 880 x 1401 inches [mm]
Summit Series with 150 Gallon Mass Transfer Vessel
- Overall (L x W x H): 2483 x 880 x 1753 inches [mm]
Summit Series with Fat Pipe Mass Transfer System
- Overall (L x W x H): 1676 x 880 x 787 inches [mm]
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Index context
-
Category hub: https://www.lenntech.com/products/ozone-generator.htm
-
Brand line: https://www.lenntech.com/products/pacific.htm
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.