Back to Pacific Ozone Generators
Pacific Ozone logo

Datasheet summary

Pacific Summit-series 12 - 60 g/h

Engineering summary from PDF text extraction for Pacific Summit-series 12 - 60 g/h. Verify every value with the OEM datasheet.

Summary

Product Identification

The Summit Series are integrated ozone systems designed to eliminate the complexity of combining feed gas preparation, ozone generation, mass transfer, and process control. These systems are offered in sanitary, splash-resistant, stainless steel skid-based packages.

Applications

  • Beverage industry
  • Bottled water
  • Food processing
  • Industrial water treatment

Features

  • Modular Ozone Chassis Design
  • Stainless Steel Frame and Enclosures
  • Air-Cooled Ceramic and Titanium Reactor Cell
  • Over-Temperature Protection
  • Optional Degas Separator
  • Redundant Backflow Prevention
  • Enhanced Mass Transfer™ ozone injection and off-gas destruction system
  • Standard stainless steel mass transfer vessels available in 50 and 150 gallons; larger vessels are also available.
  • Tank-less Fat Pipe mass transfer system available for continuous operation.

Standard Features

  • Remote On/Off ozone control
  • Remote Lockout
  • PID Controller
  • One or two channels of dissolved ozone detection
  • Ambient Ozone Detector with safety interlock (alarms at OSHA long-term exposure limit and shuts down production if OSHA short-term exposure limit is exceeded)

PLUS Option Package

  • Degas Separator: Reduces ozone off-gas by collecting undissolved ozone and shunting it to the system ozone destruct.

Additional Options

  • Process pumps
  • Additional process inputs
  • DirectDrive™ Control System
  • Optional air compressor packages

Controls

  • 4-20mA or 0-10VDC Input
  • Variable Output Control
  • Programmable PID Controller
  • Dissolved Ozone Sensor
  • Ambient Ozone Detector with Safety Interlock
  • Remote On/Off Control
  • Reactor Pressure Control
  • Feed Gas Flow Control

Operating Limits

Ozone Production and Performance

Model/Part NumberOzone Generator ModelMax. Ozone Production (lbs/day)Performance (at 2 ppm O₃) (gpm)Power Consumption (watts)
Summit A11SGA110.6252500
Summit A21SGA211.0402500
Summit A22SGA221.6652500
Summit A23SGA232.41002500
Summit A24SGA243.21302500
Summit C11SGC110.5202500
Summit C21SGC210.8352500
Summit C22SGC221.3552500

Custom, high-output systems producing up to 10 pounds of ozone per day are also available.

Ozone Destruct System

  • Catalyst: Manganese Dioxide/Copper Oxide
  • Destruct Potential: Sized to application requirements
  • Operating Temperature: 130º-140º F (54º-60º C), electronically controlled

Operational Requirements

ModelCompressed Air Flow (scfm)Compressed Air Pressure (psig)Water Pressure (psig)Electrical Requirement
Summit A1163020-30230V 50/60Hz, 1 phase 30A Circuit
Summit A2163020-30230V 50/60Hz, 1 phase 30A Circuit
Summit A2263020-30230V 50/60Hz, 1 phase 30A Circuit
Summit A23123020-30230V 50/60Hz, 1 phase 30A Circuit
Summit A24123020-30230V 50/60Hz, 1 phase 30A Circuit
Summit C11, C21, C22N/A*N/A*20-30230V 50/60Hz, 1 phase 30A Circuit

*Not Applicable - All Summit C-Line models include onboard air compression.

Mechanical / Hydraulic

Mass Transfer System Components

  • Injection Pump: Stainless steel, sized to system requirements
  • Venturi: MIC natural Kynar injector
  • Back Flow Prevention: Stainless steel check valve and proprietary backflow prevention system
  • Mass Transfer Vessel: Standard options include Fat Pipe, 50 gal., or 150 gal. Larger vessels available.
  • Inlet/Outlet: 1.5” stainless steel sanitary connections. Larger fittings available.
  • Pump Protection: Tank level switch, interlocked.
  • Assembly: Stainless steel frame.

Dimensions

Summit Series with 50 Gallon Mass Transfer Vessel

  • Overall (L x W x H): 762 x 880 x 1401 inches [mm]

Summit Series with 150 Gallon Mass Transfer Vessel

  • Overall (L x W x H): 2483 x 880 x 1753 inches [mm]

Summit Series with Fat Pipe Mass Transfer System

  • Overall (L x W x H): 1676 x 880 x 787 inches [mm]

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Index context

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.