Datasheet summary
e-idos
PDF datasheet mirror for e-idos (Calpeda Pumps). Verify with OEM before design.
Summary
Product Identification
The e-idos is a compact, plug-and-play pressurized pump system with integrated control, designed for automatic starting and stopping based on water demand. It features a programmable software and an analog pressure sensor to set the restart pressure, potentially reducing or eliminating the need for an expansion tank.
Key features include:
- High efficiency asynchronous single-phase motor, offering 24% less energy consumption compared to a standard pump.
- Integrated pressure transducer for automatic control.
- Integrated non-return valve in the pump suction.
- Capacitor less stressed in voltage.
- Uniform and lower motor temperature.
- Motor power control.
- Programmable re-start pressure.
- No hydraulic losses due to measuring devices.
- Voltage and current control.
- Monitoring of maximum starting current.
Available versions:
- E-MXP: Version with multistage pumps.
- E-NGX: Version with self-priming pumps.
- E-MXA: Version with self-priming multistage pumps.
Applications include water supply for domestic use, garden use, and irrigation.
Integrated protections:
- Dry-run protection.
- Overload control and overheating motor control.
- Pump blockage.
- Power supply control.
- Starts per hour control.
Operating Limits
- Liquid temperature: 0 °C to +35 °C (0 °C to +50 °C for E-MXP models).
- Ambient temperature: Up to +40 °C.
- Maximum permissible pressure in pump casing: 8 bar.
- Duty: Continuous.
Feed Water
Test results are based on clean cold water, without gas content. A 0.5 m security margin on NPSH-value is necessary.
Electrical
- Motor type: 2-pole induction motor.
- Frequency: 50 Hz (n ≈ 2800 rpm).
- Voltage: Single-phase 230 V ± 10%.
- Thermal protector: Integrated.
- Capacitor: Inside the terminal box.
- Cable: H07RN8-F, 3G1.5 mm², length 1.5 m, with plug CEI-UNEL 47166.
- Insulation class: F.
- Protection: IP X4.
- Standards: Constructed in accordance with EN 60034-1; EN 60335-1, EN 60335-2-41.
Mechanical / Hydraulic
Materials of Construction:
- Pump casing: Cr-Ni steel 1.4301 EN 10088 (AISI 304)
- Casing cover: Cr-Ni steel 1.4301 EN 10088 (AISI 304)
- Pump Shaft: Chrome steel 1.4104 EN 10088 (AISI 430)
- Plug: Cr-Ni steel 1.4305 EN 10088 (AISI 303)
- Suction casing (E-MXA): PPO-GF20 (Noryl)
- Stage casing (E-MXA, E-MXP): PPO-GF20 (Noryl)
- Impeller: PPO-GF20 (Noryl)
- Diffuser (E-NGX): PPO-GF20 (Noryl)
- Ejector (E-NGX): PPO-GF20 (Noryl)
- Mechanical seal: Carbon - Ceramic - NBR
Performance Data: Performance data (P1 Max. power input, P2 Rated motor power output, flow rate Q, and head H) for various models are provided in detailed tables and characteristic curves within the official PDF. This includes data for 1-pump pressurized systems (E-NGXM, E-MXPM, E-MXAM series) and 2-pumps pressurized systems (BS2F 2E-MXPM series). Tolerances are according to UNI EN ISO 9906:2012. See the official PDF for exact tabulated values and curves.
Dimensions and Weights: Net weights (kg) for various 1-pump pressurized system models (E-MXPM, E-MXAM, E-NGXM series) with a 1.5 m cable length are tabulated in the official PDF. Connection sizes, such as G 1, are also indicated. See the official PDF for exact tabulated values.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used for the project.