MGP

PDF datasheet mirror for MGP (Calpeda Pumps). Verify with OEM before design.

Summary

Product identification

The MGP series consists of Horizontal Multi-Stage Close Coupled Pumps.

Models include:

  • MGP 202, MGP 203, MGP 204, MGP 205/A
  • MGPM 202, MGPM 203, MGPM 204, MGPM 205
  • MGP 402, MGP 403, MGP 404/A, MGP 405
  • MGPM 402, MGPM 403, MGPM 404, MGPM 405

Operating limits

  • Liquid temperature: 0 °C to +50 °C
  • Ambient temperature: up to +40 °C
  • Maximum permissible pressure in the pump casing: 8 bar
  • Duty: Continuous

Feed water

  • Applications: For water supply.
  • Test conditions: Clean cold water, without gas content.

Product water

  • Applications: For domestic use, for garden use and irrigation.

Electrical

  • Motor type: 2-pole induction motor, 50 Hz (n ≈ 2800 rpm)
  • MGP (three-phase): 230/400 V ± 10%
  • MGPM (single-phase): 230 V ± 10%, with thermal protector. Capacitor inside the terminal box.
  • Insulation class: F
  • Protection: IP 54
  • Motor suitable for operation with frequency converter from 1,1 kW.
  • Classification scheme: IE3 for three-phase motors from 0,75 kW.
  • Constructed in accordance with: EN 60034-1; EN 60034-30-1; EN 60335-1, EN 60335-2-41.
  • Special features on request:
    • Other voltages
    • Frequency 60 Hz (as per 60 Hz data sheet)
    • Motor suitable for operation with frequency converter up to 0,75 kW

Mechanical / hydraulic

  • Construction:
    • Horizontal multi-stage close coupled pump.
    • Single-piece barrel casing in cast iron, with front suction port above pumps axis and radial delivery at top.
    • Stages in Noryl.
  • Materials:
    • Pump casing: Cast iron GJL 200 EN 1561
    • Casing cover: Cr-Ni steel 1.4301 EN 10088 (AISI 304)
    • Pump Shaft: Chrome steel 1.4104 EN 10088 (AISI 430)
    • Stage casing: PPO-GF20 (Noryl)
    • Impeller: PPO-GF20 (Noryl)
    • Mechanical seal: Carbon - Ceramic - NBR
  • Installation recommendations:
    • A 0,5 m security margin on NPSH-value is necessary.
    • For capacities over 4 m³/h use a suction pipe G 1 1/4 (DN 32).
  • Performance, Dimensions, and Weights:
    • Characteristic curves are provided for n ≈ 2800 rpm.
    • Detailed performance data (P1 Max. power input, P2 Rated motor power output), dimensions, and net weights are tabulated by model.