Datasheet summary
E6-12 60Hz Borehole Pumps
PDF datasheet mirror for E6-12 60Hz Borehole Pumps (Caprari Pumps). Verify with OEM before design.
Summary
Product Identification
Caprari E6-12 series electric borehole pumps are designed for 60 Hz operation.
Pump Identification Code Examples:
- E6P35-6/11N-Z
E.P: Series6: DN in inch35: Hydraulic identification number-6: Coupling flange motor/11: Number of stagesN: NEMA coupling-Z: Unit used at 60 Hz
- E8R40N-8/11-W
E: Series8: DN in inchR: Radial impeller40: Hydraulic identification numberN: NEMA coupling-8: Coupling flange motor/11: Number of stages-W: Part with operation at 50Hz / 60Hz
- E8P95-6/3D-Z
E: Series8: DN in inchP: Mixed flow impeller95: Hydraulic identification number-6: Coupling flange motor/3: Number of stagesD: Impeller trimming-Z: Unit used at 60 Hz
Submersible Motor Identification Code Examples:
- MAC635A/3A-8
MAC: Submersible motor6: Nominal diameter in inches35: Nominal power in HP/3A: HI TECH-8: Constructional features of electric motor
- MAC890-8
MAC: Submersible motor8: Nominal diameter in inches90: Nominal power in HP-8: Constructional features of electric motor
- MAC650/3B-8
MAC: Submersible motor6: Nominal diameter in inches50: Nominal power in HP/3B: HI TECH DESERT-8: Constructional features of electric motor
Mechanical / Hydraulic
Pump Construction and Materials
Common materials across various E6-12 pump types (E6P, E8P, E8R, E10R, E8RB, E10RB, E10S, E12S50, E12S55):
- Valve casing: Cast iron
- Pump shaft: Stainless steel
- Diffuser unit: Cast iron
- Cable guard: Stainless steel
- Coupling: Stainless steel
- Strainer: Stainless steel
- Bolts and nuts: Stainless steel
Variations by pump series:
- Conical valve: Stainless steel (E6P, E8P), Cast iron (E8R, E10R, E8RB, E10RB, E10S, E12S50, E12S55)
- Impeller:
- Cast iron (E6P, E8P, E10R, E10RB, E10S, E12S50, E12S55)
- Technopolymer (E8R, E8RB)
- Suction casing:
- Cast iron (E6P, E8P, E8R)
- Nodular cast iron (E10R, E8RB, E10RB, E10S, E12S50, E12S55)
- Shaft bearing bush:
- Stainless steel/rubber (E6P, E8P, E10S, E12S50, E12S55)
- Bronze (E8R, E10R, E8RB, E10RB)
- Wear ring:
- Steel/rubber (E6P, E8P, E10S)
- Stainless steel/rubber (E12S50, E12S55)
- Other components:
- Shaft sleeve: Stainless steel (E8R, E10R, E8RB, E10RB)
- Bearing bush: Bronze (E8R, E10R, E8RB, E10RB)
- Delivery casing: Cast iron (E8R, E10R, E8RB, E10RB)
- Tie rod: Steel (E8R, E10R, E8RB, E10RB)
- Intermediate bearing: Cast iron (E8RB, E10RB)
Motor Construction and Materials
Common materials across various E6-12 motor types (MPC6/3A, MPC8/1A, MPC10/1A, MAC6/3A, MAC6/3B, MAC8, MAC10/1A):
- Shaft: Stainless steel
- Sand guard: Rubber
- Rotor: Electrical steel
- Stator: Electrical steel
- Stator shell: Stainless steel
- Lower bracket: Cast iron
- Mechanical seal: Silicon carbide/silicon carbide
- Thrust-bearing foot slip: Cast iron
- Diaphragm: Rubber
- Upper bracket: Cast iron
- Bolts and nuts: Stainless steel
Variations by motor series:
- Winding: PPC (MPC6/3A, MPC8/1A, MPC10/1A), Green wire/PPC (MAC6/3A), Green wire (MAC6/3B, MAC8, MAC10/1A)
- Mechanical seal cover: Technopolymer (MPC6/3A), Stainless steel (MPC8/1A, MPC10/1A), Cast iron (MAC8)
- Bearing:
- Graphite (MPC6/3A, MPC8/1A, MPC10/1A, MAC8150, MAC10250)
- HT Synthetic (MAC6/3A, MAC6/3B)
- Bronze (MAC8, MAC10/1A)
- Thrust-bearing:
- Stainless steel/Synthetic compound (MPC6/3A, MPC8/1A, MPC10/1A, MAC10/1A)
- HT (MAC6/3A, MAC6/3B, MAC8)
- Diaphragm cover:
- Cast iron (MPC6/3A, MPC8/1A, MPC10/1A, MAC6/3B, MAC8, MAC10/1A)
- Technopolymer (MAC6/3A)
- Shaft sleeve:
- Steel (MPC6/3A, MPC8/1A, MPC10/1A)
- Chrome plated steel (MAC8, MAC10/1A)
- Other components:
- Upper cover: Cast iron (MAC6/3B, MAC8, MAC10/1A)
- Protection: Rubber (MAC8)
- Connecting flange: Cast iron (MAC8, MAC10/1A)
- Motor bracket: Cast iron (MAC8, MAC10/1A)
Operating Limits
Feed Water
- Suitable for raising chemically and mechanically non-aggressive water.
- Maximum content of solids:
- 40 g/m³ (general)
- 100 g/m³ (E6P/E8P)
- Solids should have the same hardness and granulometry as silt.
- Maximum liquid temperature:
- MPC6.. = 30°C
- MPC8.. - MPC10.. = 25°C
- MAC6.. A = 40°C (5 - 20 HP), 35°C (25 - 40 HP), 30°C (50 HP)
- MAC6.. B = 45°C (5 - 20 HP), 40°C (25 - 40 HP), 35°C (50 - 60 HP)
- MAC8... = 30°C
- MAC10... = 25°C
- Liquids with a density of 1 kg/dm³ and kinematic viscosity not more than 1 mm²/s.
Pump Operation
- Maximum operating time when the outlet is closed and the pump is submersed: 3 min.
- Hydraulic performance characteristics were measured with 460 V powered motors, cold water (15°C), and atmospheric pressure (1 bar).
- Performance is guaranteed as conforming to standard UNI/ISO 9906 Grade 3B.
- Friction losses in check valves are included for radial pumps; for mixed-flow pumps, these losses must be deducted from the total head shown in the catalogue.
Motor Operation
- Maximum submersion: 150 m.
- Speed of the water outside the motor jacket:
- 0.5 m/s for MAC... (6"-12") - MPC6.. motors
- 0.3 m/s for M14… motors
Electrical
- Standard Supply Voltage: Three-phase/60 Hz.
- Direct Starting: 6"-10": MAC...-8 460 V for all power outputs.
- Inverter Operation: All motors are fit for operation with an inverter, but a filter must be provided between the motor and the inverter to keep the voltage gradient.
- Permissible Voltage Variations: ± 5% on stated supply voltages.
- Tolerances: On operating data according to International Standards IEC 34-1.
- Thermal Probes: Available on request.
- Cable Outlet Lengths (with thermal probes):
- MPC6": 5 m
- MPC8"-10": 4 m
- MAC6": 5 m
- MAC6"-8"-10": 4 m
- MAC12": 6 m
- MAC12"-14": 5 m
Available Three-phase/60 Hz Supply Voltage and Power Ranges:
- 6" Motors:
- MPC…-8: 460 V up to 37 kW
- MPC…-9: 460/796 V up to 37 kW
- MAC...-6: 265 V up to 30 kW
- MAC...-7: 220/460 V up to 45 kW (37 kW for MAC6../3A)
- MAC...-8: 460 V up to 45 kW (37 kW for MAC6../3A)
- MAC...-9: 380/796 V up to 45 kW (37 kW for MAC6../3A), (9.2 - 45 kW for MAC6../3C)
- 8" Motors:
- MPC…-8: 460 V up to 92 kW
- MPC…-9: 460/796 V up to 92 kW
- MAC…-6: 265 V up to 75 kW
- MAC…-7: 265/460 V up to 75 kW
- MAC...-8: 460 V up to 110 kW
- MAC…-9: 460/796 V up to 110 kW
- 10" Motors:
- MPC…-8: 460 V up to 150 kW
- MPC…-9: 460/796 V up to 150 kW
- MAC…-6: 265 V up to 110 kW
- MAC…-7: 265/460 V up to 132 kW
- MAC...-8: 460 V up to 185 kW
- MAC…-9: 460/796 V up to 185 kW
Product Water
Performance ranges at 2 Poles / 60 Hz are provided in graphical format in the official PDF, showing relationships between flow rate (Q in l/s, m³/h, l/min, Imp.g.p.m., US.g.p.m.) and head (H in m, ft).
Specific operating data tables are available for various pump types (e.g., E6P35, E6P45), detailing head (m) at different capacities (l/s, l/min, m³/h) for specific motor powers (kW, HP). For example, an E6P35/2B+MAC65A pump with 4 kW (5.5 HP) motor and a 3" Gas check valve can achieve a head of 35.5 m at 0 l/s and 10.5 m at 14 l/s. NPSH values are also tabulated.
Overall Dimensions and Weights
Overall dimensions (A, B, C, D, E, G, F in mm) and weights (kg) are tabulated for specific pump models (e.g., E6P35, E6P45 series). For example, an E6P35/2B+MAC65A has a maximum diameter of 150 mm and weighs 59.5 kg.
Special Executions (Upon Request)
- Pumps can be tested according to UNI/ISO 9906 Grade 1B or Grade 2B.
- Pumps with characteristics differing from those shown in the catalogue can be supplied.
- Special pump executions can be supplied with:
- Bronze and/or stainless steel impellers.
- Bronze and/or stainless steel casing and impellers.
- Metallic stage casings and impellers instead of thermoplastic resin (for E8R35-40).
- 4 pole motors up to 22".
- For horizontal installation, if not usually foreseen.
- Motors can be supplied for:
- Other voltages and frequencies.
- Special winding for hot water (standard for MAC12300 and M14).
- Special materials for aggressive water.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.