Datasheet summary
1-2-3-KV-50
PDF datasheet mirror for 1-2-3-KV-50 (DAB Pumps). Verify with OEM before design.
Summary
Product identification
- DAB PUMPS Pressure Units
- Utilize "KV" type multi-impeller vertical axis electric pumps.
- Designed for high efficiency, application versatility, and very low noise operation.
- Available in 1, 2, or 3 pump configurations (e.g., 1 KV 50, 2 KV 50, 3 KV 50).
- Optional KV 3 jockey pump for compensation function.
- Optional weekly test run system (must be requested at time of order).
Mechanical / hydraulic
- Pumps: 1, 2, or 3 vertical multistage electric pumps, KV 50 type.
- Skid: Galvanised steel complete with 4 rubber anti-vibration feet.
- Manifolds: Flanged suction and discharge manifolds in galvanized steel, complete with blank flange.
- 1 KV 50 models: DN 80 - PN 16 or DN 80 - PN 25.
- 2 KV 50 models: DN 125 - PN 16 or DN 125 - PN 25.
- 3 KV 50 models: DN 150 - PN 16 or DN 150 - PN 25.
- Valves:
- Isolator valves on suction and discharge.
- Flanged check valve on suction side.
- Connections: Antivibration flexible coupling for connection to discharge pipe (Note: 1-2-3 KV 50/7, 1-2-3 KV 50/6, 1-2-3 KV 50/8, 1-2-3 KV 50/9 pump sets are supplied without flexible couplings).
- BY-PASS circuit: Complete with isolator valve and automatic safety valve.
- Instrumentation: Radial pressure gauge with isolator valve.
- Control Panel Mounting: Galvanized steel column for adjustable mounting of the control panel.
- Pressure Tanks: Membrane pressure tanks (Note: 1-2-3 KV 50/7, 1-2-3 KV 50/6, 1-2-3 KV 50/8, 1-2-3 KV 50/9 pump sets are supplied without membrane pressure tanks).
- Jockey Pump (Compensation Function): Available with KV 3 jockey pump (e.g., KV 3/12 T, KV 3/15 T, KV 3/18 T) complete with valves and connected to suction and discharge manifolds. Cuts in to compensate for small quantity water demand.
- Dimensions and Weights: See the official PDF for exact tabulated values for models 1 KV 50, 2 KV 50, and 3 KV 50.
Electrical
- Control Panel Cabinet: Sheet steel with IP 55 protection rating and lever handle with lock.
- Starting Methods:
- Direct Starting for unit power ratings up to 7.5 kW inclusive.
- Star-Delta starting for unit power ratings up to 9.2 kW inclusive.
- Control Circuit: Low voltage (24 Volt) feeding remote motor protectors.
- Features:
- Door lock switch.
- Remote motor protectors with thermal relays and electric pump fuses.
- Adjustable delayed pumps stop time (supplementary run).
- System to change starting sequence for sets of 2-3 electric pumps.
- Selector for Automatic (via pressure switches on discharge manifold) or Manual operation.
- Terminal board for connection of minimum pressure switch for pump stopping, float switch to protect against dry running, remote pump start command.
- Control Pressure Switches: Precalibrated and installed on the discharge manifold; operate remote motor protectors to invert electric pumps in cascade mode.
- Jockey Pump Electrical Control:
- For 1-2 K sets: Electric control and protection circuit in main electric pump control cabinet.
- For 3 K pump sets: Separate control cabinet.
- Weekly Test Run System (Optional):
- Composed of a programmable weekly timer, an audible/illuminated alarm, a drain solenoid valve on the discharge manifold, an automatic reset emergency stop pushbutton, and a minimum pressure switch.
- Starts electric pumps periodically for a few minutes to prevent mechanical seizure during prolonged disuse.
- Signals faults at the end of the test via the alarm function.
- Voltage: 3x400 V ~ (50 Hz).
- P2 Nominal, In A, Pressure Switch Setting, Max Pressure Obtainable: See the official PDF for exact tabulated values for models 1 KV 50, 2 KV 50, and 3 KV 50.
Operating limits
- Pressure Switch Setting: Ranges from 5÷7 BAR to 18÷20 BAR depending on the model.
- Max Pressure Obtainable: Ranges from 8.6 BAR to 26 BAR depending on the model.
- Manifold Pressure Rating: PN 16 or PN 25.