Summary

Product identification

These pressure units are sets featuring 2 or 3 vertical multistage electropumps of the KV 3-6-10 type from DAB PUMPS.

Available models and their corresponding codes include:

2 KV Models

  • 2 KV3/10 M: 500320102
  • 2 KV3/12 M: 500320122
  • 2 KV6/7 M: 500320272
  • 2 KV6/9 M: 500320292
  • 2 KV10/4 M: 500320442
  • 2 KV10/5 M: 500320452
  • 2 KV3/10 T: 500320602
  • 2 KV3/12 T: 500320622
  • 2 KV3/15 T: 500320652
  • 2 KV3/18 T: 500320682
  • 2 KV6/7 T: 500320772
  • 2 KV6/9 T: 500320792
  • 2 KV6/11 T: 500320812
  • 2 KV6/15 T: 500320852
  • 2 KV10/4 T: 500320942
  • 2 KV10/5 T: 500320952
  • 2 KV10/6 T: 500320962
  • 2 KV10/8 T: 500320982

3 KV Models

  • 3 KV3/10 M: 500330102
  • 3 KV3/12 M: 500330122
  • 3 KV6/7 M: 500330272
  • 3 KV6/9 M: 500330292
  • 3 KV10/4 M: 500330442
  • 3 KV10/5 M: 500330452
  • 3 KV3/10 T: 500330602
  • 3 KV3/12 T: 500330622
  • 3 KV3/15 T: 500330652
  • 3 KV3/18 T: 500330682
  • 3 KV6/7 T: 500330772
  • 3 KV6/9 T: 500330792
  • 3 KV6/11 T: 500330812
  • 3 KV6/15 T: 500330852
  • 3 KV10/4 T: 500330942
  • 3 KV10/5 T: 500330952
  • 3 KV10/6 T: 500330962
  • 3 KV10/8 T: 500330982

Mechanical / hydraulic

The hydraulic part of these sets includes:

  • 2 or 3 multistage KV 3-6-10 type vertical electropumps
  • A membrane vessel suitable for applications in the food sector
  • A radial pressure gauge
  • Threaded manifolds in galvanised steel
  • Check valve on the suction side
  • Ball valves on the suction and delivery side
  • Gauge holder cock for the control gauge
  • Anti-vibration flexible pipe

Dimensions and Weights for 2 KV Models

ModelAPH2H3H4HH1BCDSuctionDeliveryWeight Kg.
2 KV 3/10 M7955005005609611179001254125802”2”118
2 KV 3/12 M7955005005609611819001254765802”2”124
2 KV 6/7 M7955005005609610219001253165802”2”116
2 KV 6/9 M7955005005609610859001253805802”2”121
2 KV 10/4 M79550050056010892590012522058021/2”21/2”112
2 KV 10/5 M79550050056010895790012525258021/2”21/2”115
2 KV 3/10 T7955005005609611179001254125802”2”123
2 KV 3/12 T7955005005609611179001254765802”2”129
2 KV 3/15 T7955005005609612779001255725802”2”134
2 KV 3/18 T7955005005609613739001256685802”2”141
2 KV 6/7 T7955005005609610219001253165802”2”121
2 KV 6/9 T7955005005609610859001253805802”2”126
2 KV 6/11 T7955005005609611499001254445802”2”128
2 KV 6/15 T7955005005609612779001255725802”2”140
2 KV 10/4 T79550050056010892590012522058021/2”21/2”117
2 KV 10/5 T79550050056010895790012525058021/2”21/2”120
2 KV 10/6 T79550050056010898990012528458021/2”21/2”126
2 KV 10/8 T795500500560108105390012534858021/2”21/2”132

Dimensions and Weights for 3 KV Models

ModelABCDFHØ Manifold SuctionØ Manifold DeliveryWeight Kg.
3 KV 3/10 M710825120532847112221/2”21/2”156
3 KV 3/12 M710825120596911118621/2”21/2”168
3 KV 6/7 M71082512043675010262”2”153
3 KV 6/9 M710825120500815109021/2”21/2”162
3 KV 10/4 M740940120340655942DN 80DN 80201
3 KV 10/5 M740940120372690974DN 80DN 80216
3 KV 3/10 T785825120532847112221/2”21/2”156
3 KV 3/12 T785825120596911118621/2”21/2”165
3 KV 3/15 T7858251206921007128221/2”21/2”168
3 KV 3/18 T7858251207881181137821/2”21/2”183
3 KV 6/7 T785825120436750102621/2”21/2”153
3 KV 6/9 T785825120500815109021/2”21/2”162
3 KV 6/11 T785825120664880115421/2”21/2”170
3 KV 6/15 T7858251206921065128221/2”21/2”177
3 KV 10/4 T810940120340810942DN 80DN 80201
3 KV 10/5 T810940120372810974DN 80DN 80216
3 KV 10/6 T8109401204048101006DN 80DN 80210
3 KV 10/8 T8109401204688551070DN 80DN 80225

Electrical

The electrical part of these sets includes:

  • Single-phase version: One two-poles pressure switch connected to the motor, complete with power cable and electric plug.
  • Three-phase version: Overload cutout panel with rearm push button, complete with terminal board for connection to the power line, and 1 pressure switch connected to the overload cutout panel.

Electrical Data - 2 KV Models

ModelVoltage 50 HzP2 Nominal kW X2HP X2In A X2Max Pressure Obtainable BARPressure Switch Setting in BAR
2 KV3/10 M1 X 230 V ~1,11,52x7,88,24,5÷6
2 KV3/12 M1 X 230 V ~1,522x9,610,25,5÷7
2 KV6/7 M1 X 230 V ~1,11,52x7,563,5÷5
2 KV6/9 M1 X 230 V ~1,522x9,484,5÷6
2 KV10/4 M1 X 230 V ~1,11,52x8,33,81,5÷3
2 KV10/5 M1 X 230 V ~1,522x10,44,82,5÷4
2 KV3/10 T3 X 400 V ~1,11,52x5,6-3,28,24,5÷6
2 KV3/12 T3 X 400 V ~1,522x6,4-3,710,25,5÷7
2 KV3/15 T3 X 400 V ~1,852,52x7,5-4,3137,5÷9
2 KV3/18 T3 X 400 V ~2,232x10-5,815,89,5÷11
2 KV6/7 T3 X 400 V ~1,11,52x5-2,963,5÷5
2 KV6/9 T3 X 400 V ~1,522x6,2-3,684,5÷6
2 KV6/11 T3 X 400 V ~1,852,52x7,3-4,29,85,5÷7
2 KV6/15 T3 X 400 V ~2,232x11-6,3137,5÷9
2 KV10/4 T3 X 400 V ~1,11,52x6,1-3,53,81,5÷3
2 KV10/5 T3 X 400 V ~1,522x6,8-3,94,82,5÷4
2 KV10/6 T3 X 400 V ~1,852,52x8,7-55,53,5÷5
2 KV10/8 T3 X 400 V ~2,232x11,8-6,87,24,5÷6

Electrical Data - 3 KV Models

ModelVoltage 50 HzP2 Nominal kW X3HP X3In A X3Max Pressure Obtainable BARPressure Switch Setting in BAR
3 KV3/10 M1 X 230 V ~1,11,53x7,88,24÷6
3 KV3/12 M1 X 230 V ~1,523x9,610,26÷8
3 KV6/7 M1 X 230 V ~1,11,53x7,563÷5
3 KV6/9 M1 X 230 V ~1,523x9,485÷7
3 KV10/4 M1 X 230 V ~1,11,53x8,33,82÷3
3 KV10/5 M1 X 230 V ~1,523x10,44,83÷4
3 KV3/10 T3 X 400 V ~1,11,53x5,6-3,28,24÷6
3 KV3/12 T3 X 400 V ~1,523x6,4-3,710,26÷8
3 KV3/15 T3 X 400 V ~1,852,53x7,5-4,3138÷10
3 KV3/18 T3 X 400 V ~2,233x10-5,815,810÷12
3 KV6/7 T3 X 400 V ~1,11,53x5-2,963÷5
3 KV6/9 T3 X 400 V ~1,523x6,2-3,685÷7
3 KV6/11 T3 X 400 V ~1,852,53x7,3-4,29,86÷8
3 KV6/15 T3 X 400 V ~2,233x11-6,3138÷10
3 KV10/4 T3 X 400 V ~1,11,53x6,1-3,53,82÷3
3 KV10/5 T3 X 400 V ~1,523x6,8-3,94,83÷4
3 KV10/6 T3 X 400 V ~1,852,53x8,7-55,54÷5
3 KV10/8 T3 X 400 V ~2,233x11,8-6,87,25÷6

Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the official OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.