Back to DAB Pumps
DAB logo

Datasheet summary

2-3-NKVE-10-15-20-MCE

PDF datasheet mirror for 2-3-NKVE-10-15-20-MCE (DAB Pumps). Verify with OEM before design.

Summary

Product identification

  • Product Line: DAB Pump 2-3 NKVE 10-15-20 MCE
  • Description: Booster sets composed of 2 or 3 multistage vertical electropumps (NKVE MCE), each driven by an MCE/P inverter, designed for constant pressure applications.
  • Available Series:
    • 2NKVE 10/x MCE 400-50 series
    • 2NKVE 15/x MCE 400-50 series
    • 2NKVE 20/x MCE 400-50 series
    • 3NKVE 10/x MCE 400-50 series
    • 3NKVE 15/x MCE 400-50 series
    • 3NKVE 20/x MCE 400-50 series
  • Note: Specific model numbers and corresponding codes are provided in the official PDF.

Mechanical / Hydraulic

  • Boosters Composition: N. 2-3 multistage vertical electropumps NKVE MCE.
  • Impellers: INOX AISI 304
  • Liquid Contact Parts: All parts in contact with liquid are stainless.
  • Motor: Threephase asyncronous motor, rigid coupling motor-pump.
  • Baseplate: Galvanised baseplate for all pumps.
  • Manifolds: Inox AISI 304 suction and delivery manifolds.
  • Valves:
    • Stop valves on each pump’s suction.
    • Stop valves and non-return valves on each pump’s delivery.
  • Pressure Vessels: N. 2-3 pressure vessels on delivery manifold.
  • Performance (per pump set):
    • Flow Rate: Ranges from 26 m³/h to 87 m³/h.
    • Max Pressure Obtainable: Ranges from 4 BAR to 14 BAR.
    • Standard Pressure: Ranges from 3.5 BAR to 13 BAR.
    • Note: See the official PDF for exact tabulated values for specific models.

Electrical

  • Inverter: N.1 MCE/P inverter on each pump.
  • Control Unit: N.1 protection control unit on baseplate.
  • Pressure Transmitter: N.1 pressure transmitter on delivery manifold.
  • Voltage:
    • 1 X 230V ~
    • 3 X 400 V ~
  • Frequency: 50 Hz
  • Electrical Data (per pump set):
    • P2 Nominal: Ranges from 2x2.2 kW to 2x11 kW (for 2-pump sets) and 3x2.2 kW to 3x11 kW (for 3-pump sets).
    • HP: Ranges from 2x3 HP to 2x15 HP (for 2-pump sets) and 3x3 HP to 3x15 HP (for 3-pump sets).
    • In (Current): Ranges from 2x15.2 A to 2x25.5 A (for 2-pump sets) and 3x15.2 A to 3x25.5 A (for 3-pump sets).
    • Note: See the official PDF for exact tabulated values for specific models and corresponding MCE TYPE.

Disclaimer

This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the complete OEM PDF datasheet. Contractual data for any project must always match the specific OEM PDF revision used for that project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.