2-K

PDF datasheet mirror for 2-K (DAB Pumps). Verify with OEM before design.

Summary

Product identification

The document describes booster sets equipped with two twin impeller centrifugal K pumps. Each set includes a base, suction and delivery manifolds, and two membrane vessels.

Available models and their codes:

  • 2 K35/40 M: 500124020
  • 2 K35/40 T: 500124520
  • 2 K45/50 M: 500124040
  • 2 K45/50 T: 500124540
  • 2 K55/50 M: 500124060
  • 2 K55/50 T: 500124560
  • 2 K55/100 T: 500124620
  • 2 K66/100 T: 500124640
  • 2 K90/100 T: 500124660

Electrical

The electrical panel features an automatic inverter for exchanging the pump starting order at each start-up, along with a main switch. Protection against operation without water can be achieved by inserting a float or pressure switch. The low voltage auxiliary circuit is complete with a transformer and fuse. The units are supplied with tanks and an air feeder connection.

Electrical Data:

MODELMAX PRESSURE OBTAINABLE BARPRESSURE SWITCH SETTING IN BARVOLTAGE 50 HzP2 NOMINAL kW X 2HP X 2In A
2 K35/40 M4.22.2÷3.31 X 230 V ~0.7512x5.5
2 K35/40 T4.22.2÷3.33 X 400 V ~0.7512x3.5
2 K45/50 M5.22.9÷4.61 X 230 V ~1.11.52x8.3
2 K45/50 T5.22.9÷4.63 X 400 V ~1.11.52x3.6
2 K55/50 M6.23.4÷5.31 X 230 V ~1.852.52x12.8
2 K55/50 T6.23.4÷5.33 X 400 V ~1.852.52x4.8
2 K55/100 T6.23.5÷5.53 X 400 V ~2.232x6.7
2 K66/100 T7.34.3÷6.53 X 400 V ~342x8.4
2 K90/100 T8.45.5÷83 X 400 V ~45.52x9.7

Mechanical / hydraulic

The booster sets are supplied with 2 twin impeller centrifugal K pumps, complete with base, suction and delivery manifold, and 2 membrane vessels.

Dimensions and Weights: (Units for A, B, C, D, E, H, H1, H2 are not specified in the extracted text.)

MODELABCDEHH1H2Ø MANIFOLD SUCTIONØ MANIFOLD DELIVERYWEIGHT Kg.
2 K 35/40 M7005405005554009104571502”1 1/2”69
2 K 45/40 M7005405005554009104802052”1 1/2”85
2 K 55/40 M7005405005554009104802052”1 1/2”92
2 K 35/40 T7005405005554009104571502”1 1/2”73
2 K 45/40 T7005405005554009104802052”1 1/2”89
2 K 55/40 T7005405005554009104802052”1 1/2”92
2 K 55/100 T90058050055540011205702202 1/2”2 1/2”155
2 K 66/100 T90058050055540011205702202 1/2”2 1/2”160
2 K 90/100 T90058050055540011205702202 1/2”2 1/2”167

Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the official OEM PDF datasheet. Contractual data for any project must always match the specific OEM PDF revision used for that project.