Back to DAB Pumps
DAB logo

Datasheet summary

2-NKV-AD-10-15

PDF datasheet mirror for 2-NKV-AD-10-15 (DAB Pumps). Verify with OEM before design.

Summary

Product identification

  • Product Type: Booster sets with Active Driver for constant pressure.
  • Applications: Specifically suitable for civil or industrial use, irrigation systems, and washing installations.
  • Models and Codes:
    • 2NKV A.D. 10/5 T: 60120087
    • 2NKV A.D. 10/6 T: 60120088
    • 2NKV A.D. 10/7 T: 60120089
    • 2NKV A.D. 10/8 T: 60120090
    • 2NKV A.D. 10/9 T: 60120091
    • 2NKV A.D. 10/10 T: 60120092
    • 2NKV A.D. 10/12 T: 60120093
    • 2NKV A.D. 10/14 T: 60120094
    • 2NKV A.D. 15/3 T: 60120095
    • 2NKV A.D. 15/4 T: 60120096
    • 2NKV A.D. 15/5 T: 60120097
    • 2NKV A.D. 15/6 T: 60120098
    • 2NKV A.D. 15/7 T: 60120099

Mechanical / Hydraulic

Construction Features - Components:

  • 2 NKV 10-15 type multistage vertical centrifugal electric pumps
  • Skid in galvanized sheet steel
  • Suction and discharge manifolds in galvanized steel (stainless steel on request)
  • Ball valves with union on suction and discharge ports of each pump
  • Check valves on discharge ports of each pump
  • 2 plugs or blank flanges in galvanized steel for closing manifolds
  • Radial pressure gauge with isolator valve
  • 1 8 litre membrane pressure tank

Hydraulic Data Summary:

  • 2NKV A.D. 10/x T Series:
    • Flow rate (Q): 4-24 m³/h
    • Head (H): Ranges from 50-30 m to 140-80 m
    • Suction/Discharge Ø: 2” 1/2
  • 2NKV A.D. 15/x T Series:
    • Flow rate (Q): 8-30 m³/h
    • Head (H): Ranges from 40-30 m to 90-70 m
    • Suction/Discharge Ø: DN 100 / DN80

The document includes performance curves for Q (l/s, l/min, US gpm, IMP gpm, m³/h) versus P (kPa) and H (m, Ft) for both 10/x and 15/x series models.

Electrical

Electrical Section Components:

  • 1 Modulo Active Driver on discharge line of each pump
  • 1 protection control unit

Electrical and Performance Data (per pump, as indicated by "X 2" for P2 and HP):

ModelVoltage 50 HzP2 Nominal (kW x 2)HP x 2Q (m³/h)H (m)Suction ØDischarge ØWeight (Kg)
2NKV A.D. 10/5 T3 X 400 V ~2,234-2450-302” 1/22” 1/2276
2NKV A.D. 10/6 T3 X 400 V ~2,234-2460 -302” 1/22” 1/2578
2NKV A.D. 10/7 T3 X 400 V ~344-2470-402” 1/22” 1/2298
2NKV A.D. 10/8 T3 X 400 V ~344-2480-502” 1/22” 1/2300
2NKV A.D. 10/9 T3 X 400 V ~344-2490-502” 1/22” 1/2302
2NKV A.D. 10/10 T3 X 400 V ~45,54-24100-602” 1/22” 1/2322
2NKV A.D. 10/12 T3 X 400 V ~45,54-24120-702” 1/22” 1/2326
2NKV A.D. 10/14 T3 X 400 V ~5,57,54-24140 - 802” 1/22” 1/2382
2NKV A.D. 15/3 T3 X 400 V ~348-3040-30DN 100DN80314
2NKV A.D. 15/4 T3 X 400 V ~45,58-3050-40DN 100DN80334
2NKV A.D. 15/5 T3 X 400 V ~45,58-3065-50DN 100DN80336
2NKV A.D. 15/6 T3 X 400 V ~5,57,58-3080-60DN 100DN80392
2NKV A.D. 15/7 T3 X 400 V ~5,57,58-3090-70DN 100DN80395

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used for the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.