Datasheet summary
KVE-50
PDF datasheet mirror for KVE-50 (DAB Pumps). Verify with OEM before design.
Summary
Product identification
The DAB KVE 50 is a vertical multistage centrifugal pump designed for pressurization systems, suitable for medium and high consumption water systems. It features an MCE/P inverter for automatic performance adjustment to system requirements, maintaining constant differential pressure.
Operating limits
- Operating range: 12 to 45 m³/h, with head up to 240 m (2 poles)
- Liquid temperature range: -15°C to 110°C
- Maximum ambient temperature: +40°C
- Maximum working pressure: 30 bar (3000 kPa)
- Installation: Fixed, in a vertical position
Feed water
The pumped liquid must be clean, free from solids or abrasive substances, not viscous, not aggressive, not crystallized, and chemically neutral.
Electrical
- Protection rating: IP 55
- Insulation class: F
- Standard voltage: Three-phase 3x400 V / 50 Hz
Mechanical / hydraulic
- Discharge and suction bodies: Corrosion treated cast iron
- Motor support and diffuser bodies: Corrosion treated cast iron
- Impeller: Bronze
- Diffuser: Cast iron
- Shaft and relative sliding bush: AISI 416 stainless steel
- Sliding bush guide: Bronze, self-lubricated
- Mechanical seal: Carbon/tungsten carbide
- Motor shaft - pump shaft connection: Rigid coupling
- Motor: Two-pole, asynchronous, closed and cooled by external ventilation
- Accessories: Threaded counter flanges supplied as standard
KVE 50 Models with MCE/P
| Model | Code | Voltage | P2 Nominal (kW) | P2 Nominal (HP) | In (A) | DNA (GAS) | DNM (GAS) | H (mm) | Weight (Kg) |
|---|---|---|---|---|---|---|---|---|---|
| KVE 50/3 T MCE110/P | 60144942 | 3 x 400 V | 9.2 | 12.5 | 20.6 | 65 | 50 | 1127 | 162 |
| KVE 50/4 T MCE110/P | 60144943 | 3 x 400 V | 11 | 15 | 27.6 | 65 | 50 | 1181 | 190 |
| KVE 50/5 T MCE150/P | 60144944 | 3 x 400 V | 14.7 | 20 | 31.4 | 65 | 50 | 1235 | 242 |
Hydraulic performance data (flow rate Q vs. head H) for these models is available in the official PDF datasheet.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.