Back to DAB Pumps
DAB logo

Datasheet summary

NKVE-10-15-20-WITH-ADAC

PDF datasheet mirror for NKVE-10-15-20-WITH-ADAC (DAB Pumps). Verify with OEM before design.

Summary

Product identification

  • Models:
    • 2NKVE 15/3 T ADAC 400-50 (Code: 60151808)
    • 2NKVE 15/4 T ADAC 400-50 (Code: 60151809)
    • 2NKVE 10/6 T ADAC 400-50 (Code: 60151810)
    • 2NKVE 20/4 T ADAC 400-50 (Code: 60151811)
  • Description: Booster sets for constant pressure, composed of two multistage vertical electropumps (NKVE ADAC), each driven by an ADAC inverter.

Operating limits

  • 2NKVE 15/3 T ADAC 400-50:
    • Max Flow Rate: 48 m³/h
    • Max Pressure Obtainable: 4 bar
    • Standard Pressure: 3.5 bar
    • DNA: 100
    • DNM: 80
    • Weight: 258 (unit not specified in extract)
  • 2NKVE 15/4 T ADAC 400-50:
    • Max Flow Rate: 48 m³/h
    • Max Pressure Obtainable: 5 bar
    • Standard Pressure: 4 bar
    • DNA: 100
    • DNM: 80
    • Weight: 278 (unit not specified in extract)
  • 2NKVE 10/6 T ADAC 400-50:
    • Max Flow Rate: 26 m³/h
    • Max Pressure Obtainable: 6 bar
    • Standard Pressure: 5 bar
    • DNA: 2” ½
    • DNM: 2” ½
    • Weight: 207 (unit not specified in extract)
  • 2NKVE 20/4 T ADAC 400-50:
    • Max Flow Rate: 58 m³/h
    • Max Pressure Obtainable: 6 bar
    • Standard Pressure: 5 bar
    • DNA: 100
    • DNM: 80
    • Weight: 280 (unit not specified in extract)

Electrical

  • 2NKVE 15/3 T ADAC 400-50:
    • Voltage: 3 X 400 V ~ 50 Hz
    • P2 Nominal: 2x7.37 kW
    • In: 3 A
    • Inverter Model: AD T/T 3.0 AC
    • Model Quadro: E2G11T MCE(16A MAX) 400V C/CAVI
  • 2NKVE 15/4 T ADAC 400-50:
    • Voltage: 3 X 400 V ~ 50 Hz
    • P2 Nominal: 2x10.1 kW
    • In: 4 A
    • Inverter Model: AD T/T 3.0 AC
    • Model Quadro: E2G11T MCE(16A MAX) 400V C/CAVI
  • 2NKVE 10/6 T ADAC 400-50:
    • Voltage: 3 X 400 V ~ 50 Hz
    • P2 Nominal: 2x5.4 kW
    • In: 2.2 A
    • Inverter Model: AD T/T 3.0 AC
    • Model Quadro: E2G11T MCE(16A MAX) 400V C/CAVI
  • 2NKVE 20/4 T ADAC 400-50:
    • Voltage: 3 X 400 V ~ 50 Hz
    • P2 Nominal: 2x13.1 kW
    • In: 5.5 A
    • Inverter Model: AD T/T 4.0 AC
    • Model Quadro: E2G11T MCE(16A MAX) 400V C/CAVI

Mechanical / hydraulic

  • Impellers: INOX AISI 304
  • Parts in contact with liquid: Stainless
  • Motor type: Three-phase asynchronous motor
  • Motor-pump coupling: Rigid
  • Baseplate: Galvanised for all pumps
  • Suction and delivery manifolds: Inox AISI 304
  • Valves: Stop valves on each pump’s suction; stop valves and non-return valves on each pump’s delivery.
  • Pressure vessels: 2 pressure vessels on delivery manifold.

Disclaimer: This summary is based on extracted text and may miss figures, footnotes, or revisions present in the full OEM PDF. Contractual data must always match the specific OEM PDF revision used on the project.