Back to ESPA Pumps
ESPA logo

Datasheet summary

Acuaplus

PDF datasheet mirror for Acuaplus (ESPA Pumps). Verify with OEM before design.

Summary

Product identification

  • Acuaplus N Pressure
  • Submersible multistage pump with variable speed
  • Equipped with electronic variable speed regulation and integrated pressure sensor for constant pressure.

Applications

  • Pressurising domestic water for houses, semi-detached homes, apartments, chalets, and rural homes.

Operating limits

  • Maximum working pressure: 8 bar
  • Ø of solids: 2 mm
  • Water temperature: 4 °C to 35 °C
  • Maximum start-ups: 30/hour
  • Installation: Vertical or horizontal

Materials

  • Outer casing, discharge body, impellers, filter, discharge cover, motor casing: AISI 304 stainless steel
  • Pump shaft: AISI 303 stainless steel
  • Diffusers: PPO
  • Mechanical seal: aluminium oxide/graphite/steatite/NBR/AISI 304

Motor

  • Asynchronous, 2 pole
  • IP 68 protection
  • Class F insulation
  • Continuous operation
  • Water-cooled motor
  • Single-phase version with Klixon (incorporated thermal protection)
  • With level switch

Electrical

  • Model: AcuaplusN
    • Voltage: 1~230 V
    • Current (I): 4.7 A
    • Input Power (P1): 1 kW
    • Output Power (P2): 0.75 kW (1 HP)
    • Capacitor: 12 µF

Mechanical / Hydraulic

  • Incorporates a detection and protection device against functioning in dry operation, with sequential start-up attempts in the event of failure.
  • Reduces the water hammer effect on the installation.
  • Oil chamber with double mechanical seal.
  • Requires installation of a pressure vessel on the discharge pipework, minimum 18 ltrs.
  • AcuaplusN pumps are supplied with Kit Press & pressure gauge.
  • Dimensions and Weights (Model: AcuaplusN)
    • A: 517
    • B: 126
    • C: 1” (Discharge connection)
    • D: 170
    • E: 254
    • F: 175
    • Weight: 11.5 Kg
  • Performance:
    • Performance curves are shown at 2900 rpm, similar to acuaria 07/4.
    • The pump can operate at any point inside the indicated area.
    • Characteristic curves depend on the delivery pressure, with examples shown for 150, 200, and 300 kPa.
    • The operating limit curve corresponds to the maximum rotating speed.
    • See the official PDF for exact tabulated values.

Disclaimer: Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.