Product identification
The ESPA Speedrive (ESD) is a variable-frequency driver designed for integration with ESPA pump models including MULTI-ESD, PRISMA-ESD, XVM-ESD, XVM, Aspri, and Multi.
Available models:
- Speedrive M2 (Single-phase)
- Speedrive T3 (Three-phase)
- Speedrive T4 (Three-phase)
Operating limits
- IP 55 protection
- Maximum ambient temperature: 40 °C
- Minimum working frequency: Adjustable
- Acceleration ramp: 1 fixed
- Deceleration ramp: 1 fixed
- Stop temporisation: Yes
Electrical
The ESD unit regulates motor speed to maintain constant pressure based on a proportional signal from an external 4-20 mA pressure transducer.
Model-specific electrical data
- Speedrive M2 (Single-phase)
- Power source voltage: 1~230 V AC ± 10 %
- Motor voltage: 3~230 V AC
- Maximum motor current: 7 A
- Auxiliary relay: 1 for external alarm
- Free power contact: 1 (maximum intensity 2 A, 1~230 V AC)
- Speedrive T3 (Three-phase)
- Power source voltage: 3~400 V AC ± 10 %
- Motor voltage: 3~400 V AC
- Maximum motor current: 9 A
- Speedrive T4 (Three-phase)
- Power source voltage: 3~400 V AC ± 10 %
- Motor voltage: 3~400 V AC
- Maximum motor current: 13 A
Common electrical features
- Configuration: Built into the junction box
- Cooling: Air-cooled
- Nominal motor frequency: 50 Hz/60 Hz
- Digital input for 4-20 mA transducer with 24-V DC power source
- Additional digital input: 1
- Additional analogical input: 1
- Level switch terminal: Yes
- PTC: Optional
- External communication port: RS 485
Mechanical / hydraulic
The ESD modules can control pressure booster sets with up to 4 pumps.
Dimensions and Weights
- Speedrive M2:
- A: 128 mm
- B: 71 mm
- C: 207 mm
- D: 207 mm
- Weight: 2.2 kg
- Speedrive T3:
- A: 142 mm
- B: 85 mm
- C: 207 mm
- D: 207 mm
- Weight: 2.5 kg
- Speedrive T4:
- A: 142 mm
- B: 85 mm
- Weight: 2.5 kg
- Note: C and D dimensions for T4 are not provided in the extracted text. See the official PDF for full tabulated values.
Features and Control
The ESD provides a high-quality, oscillation-free service by maintaining constant pressure regardless of flow demand, leading to improved efficiency and energy savings compared to fixed-speed systems.
Operating Modes and Parameters
The ESD features a backlit display and a 5-button keypad.
- Adjustable operating parameters:
- Language: ES, EN, DE, IT, FR
- Operation: AUTOMATIC – MANUAL
- Set pressure: set point
- Differential pressure: hysteresis or difference in the set pressure that marks the start-up of the pump
- Maximum motor intensity: to regulate motor protection
- Pump sleep frequency: can be set manually or automatically (ESD can automatically calculate based on installation characteristics and set pressure)
- Displayed parameters:
- Set pressure
- Differential pressure
- Maximum motor intensity
- Stoppage frequency
- Pump stop temporisation
- Module temperature
- Alarm display: power surge, short-circuit, power failure, and module temperature
- Operational register: number of start-ups, hours in operation, and hours online
- Password protection: Access to advanced parameter settings, deletion of operational register, and alarm history.
Pump Control Capabilities
- Constant pressure: Yes
- Constant flow: Programmable
- Second duty point: Programmable
- Dry running protection: Yes
- Motor rotation reversal
- Maximum number of pumps: Up to 4
- Maximum number of slave pumps (fixed speed): Up to 3
Booster Set Configurations
The ESD modules can control booster sets in two main ways:
1. Units with one single ESD module (Master variable-speed pump, auxiliary pumps in DOL start-up):
- CKED 2 pumps: Variable-speed main pump + fixed-speed DOL auxiliary pump.
- CKED 3 pumps: Variable-speed main pump + 2 fixed-speed randomly alternating DOL auxiliary pumps.
- CKED 4 pumps: Variable-speed main pump + 3 fixed-speed randomly alternating DOL auxiliary pumps.
2. Units with multiple ESD modules (up to 4 variable-speed pumps):
- CKE2: 2 pumps: variable-speed main pump + variable-speed auxiliary pump, both operating in cyclical duty changeover.
- CKE3: 3 pumps: variable-speed main pump + 2 variable-speed auxiliary pumps, all 3 operating in cyclical duty changeover.
- CKE4: 3 pumps: variable-speed main pump + 2 variable-speed auxiliary pumps, all 3 operating in cyclical duty changeover.
- Note: For CKE4, the text specifically describes a configuration with 3 pumps.
- In multi-ESD configurations, once auxiliary pumps activate, all regulated pumps operate in synchronization at the same frequency.
Electronic Circuit Components
The electronic circuit includes:
- EMC filter
- Input/output for cables
- Power circuit
- Aluminium radiator body
- Pressure transducer
- Device for digital pressure reading