Back to ESPA Pumps
ESPA logo

Datasheet summary

Tecno-ESD

PDF datasheet mirror for Tecno-ESD (ESPA Pumps). Verify with OEM before design.

Summary

Product Identification

The Tecno ESD and Tecnoself ESD are surface horizontal pumps featuring a built-in Variable Frequency Drive (VFD). All ESD pumps are supplied with a Speedrive and a pressure transducer.

Applications

  • Constant water supply in dripping irrigation installations.
  • Industrial applications where constant pressure is required.

Operation Principle

The VFD increases and decreases the motor speed according to the installation demand, supplying constant pressure. The input signal for the VFD comes from a pressure transducer installed on the discharge pipe. The Speedrive includes built-in protections for the pump, such as dry running, temperature, and over intensity.

Operating Limits

Electrical Voltage Range

  • Low voltage:
    • Disconnect at 180 V (M2)
    • Disconnect at 310 V (T2)
    • Automatic reset: 195 V (M2)
    • Automatic reset: 335 V (T2)
  • High voltage:
    • Disconnect at 270 V (M2)
    • Disconnect at 485 V (T2)
    • Automatic reset: 250 V (M2)
    • Automatic reset: 475 V (T2)

Mechanical / Hydraulic

Pump Specifications

ModelPumpUnitP2 [kW]VfdSuctionDischarge
Tecno 25.4MESDTecno 25 410.92M2/T21”1”
Tecno 25.4TESDTecno 25 410.92M2/T21”1”
Tecno 25.5MESDTecno 25 511.1M2/T21”1”
Tecno 25.5TESDTecno 25 511.1M2/T21”1”
Tecnoself 25.4MESDTecnoself 25 410.92M2/T21”1”
Tecnoself 25.4TESDTecnoself 25 410.92M2/T21”1”
Tecnoself 25.5MESDTecnoself 25 511.1M2/T21”1”
Tecnoself 25.5TESDTecnoself 25 511.1M2/T21”1”

Note: All ESD pumps require a pressure vessel to be fitted. Minimum recommended size for Tecno/Tecnoself 25 models is 18 liters.

Dimensions and Weights

ModelABCDEFGHIDNaDNdKg
Tecno ESD 25 4236.6107.5298.1270272196.3207889G1’’G1’’14.9
Tecno ESD 25 5263.2107.5324.7270272196.3207889G1’’G1’’16.2

Materials and Motor

Materials and motor specifications are as per the pump and Speedrive pages.

Included Equipment

  • Pumps supplied with VFD integrated.
  • Pressure transducer included.

Performance Curves

Performance area curves for Tecno ESDM and Tecno ESD at 2900 rpm are available in the official PDF, showing Q (l/min, m³/h, Imp g.p.m., U.S. g.p.m.) versus H (mwc, kPa, ft). See the official PDF for exact graphical values.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.