Datasheet summary
SLP-15-8
PDF datasheet mirror for SLP-15-8 (FEDCO Pumps). Verify with OEM before design.
Summary
Product identification
- Model: SLP-15-8
- Pump Type: Single Stage, end suction, centrifugal, closed-coupled
Materials
- Casing: Zeron SS (ASTM A995-13 6A)
- Bearings: Non-metallic
- Motor Adapter: 316 SS
- Optional Baseplate: Carbon Steel - Painted (A36)
- Mechanical Seal - Type 21: SiC/ Graphite
- O-Rings: Buna N®
- Impeller: Zeron SS (ASTM A995-13 6A)
Operating limits
- Pump Operating Ambient Temp: 33 - 158 °F (0.6 - 70.0 °C)
- Maximum Storage Temp: 185 °F (85.0 °C)
- Pump Operating Flow Range: 26 - 99 gpm (5.9 - 22.8 m³/h)
- Maximum Rated Flange Pressure: 270 psi (19 bar)
- Maximum Solid Size: 0.125 in (3.175 mm)
- Head (nominal): 268 Ft (81.7 M)
- PEICL Range: 0.73 (Motor Dependent)
Feed water
- Liquid: Seawater, Brackish water, Fresh Water
Performance
- Peak Efficiency: Up to 80% (Range includes several sizes)
Electrical
- Motor Manufacturer: WEG or equivalent
- Motor Type: NEMA
- Ambient Temperature: -4 - 104 °F (-20 - 40 °C)
- Power Rating:
- 10 HP-460/60/3
- 7.5 HP-380/50/3
- Service Factor: 1.25
- Efficiency:
- 90.20% (for 10 HP)
- 88.50% (for 7.5 HP)
- Full Load Amps:
- 11.6 (for 10 HP)
- 10.4 (for 7.5 HP)
- Frame: 215 JM
- Enclosure: TEFC
- Electric Power:
- 7.5 kW (for 10 HP)
- 5.5 kW (for 7.5 HP)
- Motor Weight: 166 lbs [75.4 kg]
Mechanical / hydraulic
- Fittings:
- Pipe Joints: Flange: ASME/ANSI B16.5 Class 150
- Feed Inlet: 2”
- Feed Outlet: 1”
- Lubrication: Product fluid
- Cooling: Product fluid
- Full Impeller Diameter: 8.125 in (206.375 mm)
- Pump Weight (with base): 208 lbs (94 kg)
- Pump Package Weight: 386 lbs (175 kg)
- Crating/Packaging: Export-Wood
- Protective Covers: Standard
- Export Crating: Standard
- Additional Shipping Options: Available per customer request
Testing and Inspection
- Hydrostatic Test: Standard
- Mechanical Run Test: Standard
- Factory Duty Point Hydraulic Performance Test: Not Available
- Material Certificates: Optional