Back to Flygt Pumps
Flygt logo

Datasheet summary

CS 3400/805

PDF datasheet mirror for CS 3400/805 (Flygt Pumps). Verify with OEM before design.

Summary

Product identification

  • Flygt C-pumps 3068–3800 series.
  • Submersible waste and raw water pumps.

Operating limits

  • General performance range: up to approx. 3000 l/s.

Feed water

  • Suitable for a variety of applications, including:
    • Pumping sewage in municipal applications
    • Irrigation
    • Industrial effluent
    • Cooling water
    • Storm water
    • Process water
    • Raw water

Electrical

  • Motor:
    • Squirrel cage, high performance induction motor, specially designed and manufactured by Xylem for submersible use.
    • Stator windings are trickle impregnated in resin to Class H insulation.
    • Rated at 180°C (355°F).
    • Many units provide up to 30 starts per hour.
  • Motor Ratings:
    • Up to 680 kW (50 Hz)
    • Up to 1040 hp / 775 kW (60 Hz)
  • Monitoring:
    • Thermal sensors embedded in the stator windings help prevent overheating.
    • Leakage sensors in the stator and oil housings, together with external monitoring equipment, are available as options.
  • Cable Entry:
    • Designed to incorporate both a seal and a strain relief function.

Mechanical / hydraulic

  • Construction:
    • Standard version: Made in cast iron.
    • Industrial configurations available for more demanding applications.
    • Explosion-proof versions are available.
  • Installation Methods:
    • CS: A semi-permanent, free-standing installation; transportable version with pipe or hose connection.
    • CT: A vertically-mounted, permanent dry well or in-line installation with flange connections for suction and discharge pipe work.
    • CZ: A horizontally-mounted, permanent dry well or in-line installation with flange connections for suction and discharge pipe work.
    • CP: For semi-permanent wet well installations; the pump is installed with twin guide bars on a discharge connection.
  • Shaft:
    • A short overhang of the shaft virtually eliminates shaft deflection, resulting in significantly increased seal and bearing life, low vibration, and quiet operation.
  • Seals:
    • Two sets of mechanical shaft seals that work independently for double security, designed, patented, and manufactured by Xylem.
  • Oil Housing:
    • Food-grade oil-filled compartment that lubricates the seals, diffuses heat from the motor and bearings, and provides additional security against penetration by liquids.
  • Impeller:
    • Flygt Nevaclog® impeller: Designed specially for smaller Flygt C-pumps with excellent flow passing properties, eliminating parts that might cause clogging.
    • Multi-vane impellers: For bigger pumps, designed for optimum hydraulic efficiency; dynamically balanced and machined to match the requested duty point.
    • The area in the pump housing at the upper and lower shroud of the impeller has a labyrinth seal design to prevent leakage and clogging, improving efficiency.
    • Replaceable wear rings are standard.
  • Seal Wear Protection:
    • Spin-out™ is a patented design that protects the outer seal by expelling abrasive particles from the seal chamber.
  • Cooling System:
    • In normal applications, the surrounding liquid cools the pump motor.
    • In more demanding applications, or when dry installed, the pumps can be fitted with an integrated cooling system.

Compliance / Approvals

  • All pumps are tested and approved in accordance with national and international standards (IEC 34-1 CSA).
  • Explosion-proof versions are available with Factory Mutual (FM) and European Norm (EN) approvals.