Back to Flygt Pumps
Flygt logo

Datasheet summary

Concertor DP N100-7800

PDF datasheet mirror for Concertor DP N100-7800 (Flygt Pumps). Verify with OEM before design.

Summary

Product identification

The Concertor DP N100-7800 is a process-controlled wastewater pumping system. It consists of the required number of pumps for a customer's application, along with one gateway per pump. It is designed for customers who own specially designed process control algorithms, offering benefits such as lower capital costs, smaller control cabinets, higher pump system efficiencies, clog detection, and pump cleaning.

  • Model: Concertor DP N100-7800
  • Impeller material: Grey cast iron
  • Installation type: P - Semi Permanent, Nat (Clean water standard)

Operating limits

  • Gateway operation temperature: -20˚C to +70˚C

Electrical

  • Motor type: 3~
  • Nominal voltage: 400 V
  • Nominal power: 7.3 kW
  • Rated speed: 500-2146 rpm
  • Rated current: 12 A
  • Starting current: 12 A
  • Frequency: 50/60 Hz
  • Set power: 7800 W
  • Drive and Motor efficiency: Values are listed for 1/1 Load, 3/4 Load, and 1/2 Load, but specific numerical values are not provided in the extracted text.

Mechanical / hydraulic

  • Pump weight: 117 kg (258 lbs)
  • Stand weight: 43 kg (95 lbs)
  • Suction side diameter: DN100 [4"]
  • Discharge connection: 100 mm
  • Impeller diameter: 200 mm
  • Number of blades: 2
  • Guide bars: 2"
  • Efficiency (Rendement): 78.4%

Performance curves for head (Opvoerhoogte) and flow are present in the document, showing head up to approximately 32 m and flow up to approximately 280 m³/h. Specific tabulated values are not clearly readable in the extract. See the official PDF for exact tabulated values.

Monitoring & Control (Gateway)

The system includes a gateway with the following specifications:

  • Power Supply: 24 V DC
  • Ports:
    • 1 x USB
    • 1 x RS485
    • 1 x Ethernet RJ 45
    • 1 x Display interface, CAN
  • Communication:
    • Modbus RTU
    • Modbus TCP
  • Standard I/O:
    • 4 x Digital outputs
    • 4 x Digital inputs
    • 1 x Analog input
    • 1 x Analog output
  • Pump Interface: 1 x Pump Communication Port
  • User Interface:
    • 14 x LED
    • 1 x Rotator Switch
  • Data Logging: 1000 data points
  • Environment Class:
    • Protection class: IP 20
  • Software Version: DP software – Variable performance control via external signal, status and alarms
  • Approvals: CE, UL, CSA
  • Interface (HMI): None

Dimensions

A dimensional drawing is included in the original document. See the official PDF for exact dimensions.

Life Cycle Costs (LCC)

The document includes a section for Life Cycle Costs (LCC) and First Year Costs, but all values for Energy, Investment costs, Installation & commissioning, Operating cost, Maintenance & repair, Downtime, Environmental, and Decommissioning are listed as 0% or 0,00 EUR in the extracted text, indicating placeholder values.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used for the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.