Datasheet summary
CME-10
PDF datasheet mirror for CME-10 (Grundfos Pumps). Verify with OEM before design.
Summary
Product identification
The Grundfos CME 10 is a horizontal, multistage centrifugal pump. CME pumps are built upon the CM pump range, distinguished by their Grundfos MGE motor. This motor is designed to EN standards and incorporates a frequency converter, enabling continuously variable control of motor speed.
CME pumps are suitable for applications requiring:
- Controlled operation with fluctuating consumption
- Constant pressure
- Communication with the pump
Benefits of frequency-controlled speed include energy savings, increased comfort, and enhanced control and monitoring of the application and pump performance.
The CME 10 is available in:
- Cast-iron version (CME 10-A)
- Stainless-steel versions (CME 10-I and CME 10-G)
Operating limits
CME pumps operate at 50/60 Hz. The 100% speed of CME pumps is approximately 3400 min⁻¹, irrespective of the input frequency.
Performance curves for Head (H), Flow rate (Q), Input Power (P₂), Net Positive Suction Head (NPSH), and Efficiency (Eta) are available for CME 10 models, showing a range of operation from minimum to maximum performance curves. See the official PDF for exact tabulated values and performance graphs.
Electrical
CME pumps are available with the following supply voltages:
- 1 x 200-240 V, 50/60 Hz (supply voltage K)
- 1 x 208-230 V, 50/60 Hz (supply voltage M)
- 3 x 380-480 V, 50/60 Hz (supply voltage L)
- 3 x 460-480 V, 60 Hz (supply voltage N)
Output power (P₂) for CME 10 models ranges from 1.10 kW to 5.5 kW.
Mechanical / hydraulic
The pump materials are identical to those of the CM pump range.
Construction Materials:
- Motor parts:
- Motor flange: Cast iron
- Stator housing: Silumin (Alu)
- Fan cover: Composite PBT/PC
- Fan: Composite PA 66 30% GF
- Corrugated spring: Steel
- Terminal box: Composite PC/ASA or silumin (Alu)
- Base plate: Steel, electro-coated or powder-coated
- Diverting disc: Silicone fluid (LSR)
- Bearing cover plate: PPS
- Pump parts:
- Shaft seal steel parts: Stainless steel 1.4301/AISI 304 or 1.4401/AISI 316
- Shaft seal faces: Al₂O₃/carbon or SiC
- Pump shaft: Stainless steel 1.4057/AISI 431, 1.4301/AISI 304, or 1.4401/AISI 316
- O-rings: EPDM, FKM or FFKM
- Gasket: Paper or Aramide fibres (nbr)
- Discharge part (CME-A): Cast iron
- Inlet part (CME-A): Cast iron
- Chamber: Stainless steel 1.4301/AISI 304 or 1.4401/AISI 316
- Plug: Stainless steel 1.4404/AISI 316L
- Impeller: Stainless steel 1.4301/AISI 304 or 1.4401/AISI 316 (specific models use 1.4401 as standard)
- Spacing pipe: Stainless steel 1.4401/AISI 316
- Clamp: Stainless steel STX2000 (~ CrNiMO 22 19 4)
- Flange (CME-I/G): Cast iron
- Sleeve: Stainless steel 1.4301/AISI 304 or 1.4401/AISI 316
- Nut: Stainless steel A4
- Washer (NORD-LOCK®): Steel 1.4547
Connections:
- Suction/Discharge: Rp 1 1/2 or NPT 1 1/2
- Auxiliary: Rp 3/8
Dimensions: Detailed dimensional drawings and tables (A1-A4, B1-B3, H, H1, H2, L1-L9) are provided for CME 10-A, CME 10-I, and CME 10-G models across various power ratings and voltages. See the official PDF for exact tabulated values.
Weights and Shipping Volume:
- CME 10-A (Cast Iron):
- CME 10-1 (1 x 200-240 V / 1 x 208-230 V): Net weight 25.9 kg, Gross weight 29.4 kg, Shipping volume 0.0370 m³
- CME 10-2 (3 x 380-480 V): Net weight 41.6 kg, Gross weight 45.1 kg, Shipping volume 0.0847 m³
- CME 10-3 (3 x 380-480 V): Net weight 63.5 kg, Gross weight 67.0 kg, Shipping volume 0.0847 m³
- CME 10-2 (3 x 460-480 V): Net weight 41.7 kg, Gross weight 45.2 kg, Shipping volume 0.0847 m³
- CME 10-3 (3 x 460-480 V): Net weight 60.2 kg, Gross weight 63.7 kg, Shipping volume 0.0847 m³
- CME 10-I and CME 10-G (Stainless Steel):
- CME 10-1 (1 x 200-240 V / 1 x 208-230 V): Net weight 21.3 kg, Gross weight 24.8 kg, Shipping volume 0.0370 m³
- CME 10-2 (3 x 380-480 V): Net weight 36.6 kg, Gross weight 40.1 kg, Shipping volume 0.0847 m³
- CME 10-3 (3 x 380-480 V): Net weight 57.9 kg, Gross weight 61.4 kg, Shipping volume 0.0847 m³
- CME 10-4 (3 x 380-480 V): Net weight 58.8 kg, Gross weight 62.3 kg, Shipping volume 0.0847 m³
- CME 10-5 (3 x 380-480 V): Net weight 60.2 kg, Gross weight 63.7 kg, Shipping volume 0.0847 m³
- CME 10-2 (3 x 460-480 V): Net weight 36.7 kg, Gross weight 40.2 kg, Shipping volume 0.0847 m³
- CME 10-3 (3 x 460-480 V): Net weight 54.6 kg, Gross weight 58.1 kg, Shipping volume 0.0847 m³
- CME 10-4 (3 x 460-480 V): Net weight 55.5 kg, Gross weight 59.0 kg, Shipping volume 0.0847 m³
- CME 10-5 (3 x 460-480 V): Net weight 60.6 kg, Gross weight 64.1 kg, Shipping volume 0.0847 m³
Communication & Control
Communication with CME pumps is possible via:
- Central building management system: Allows remote monitoring and changes to control modes and setpoint settings.
- Remote control (Grundfos R100): An accessory that enables communication by pointing an IR-signal transmitter at the control panel of the terminal box to monitor and change settings.
- Control panel: Allows manual adjustment of setpoint settings on the CME pump terminal box.
Communication Interface Units (CIUs) are available for network integration:
- CIU 100: LON
- CIU 150: PROFIBUS DP
- CIU 200: Modbus RTU
- CIU 250: GSM
- CIU 270: GRM
- CIU 300: BACnet MS/TP
CME pumps can connect to LON, PROFIBUS, Modbus, GSM, GRM, or BACnet networks.
Grundfos WinCAPS and WebCAPS selection programs can calculate specific duty points and energy consumption for CME pumps.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used for the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.