Back to Nocchi Pumps
Pentair logo

Datasheet summary

Nocchi ADRM

PDF datasheet mirror for Nocchi ADRM (Nocchi Pumps). Verify with OEM before design.

Summary

Product identification

Nocchi ADRM Single Phase Electrical Panels for control of one or two drainage and waste water pumps.

  • ADRM 10: Electrical panel for control of one electric pump.
  • ADRM 20: Electrical panel for control of two electric pumps, with sequential start-up inverter.

Operating limits

  • Protection rating: IP54
  • Ambient temperature: -5 / +40 °C
  • Relative humidity: 50% at 40°C condensate free
  • Reference standards: EN 60730 - EN 60439

Electrical

  • Power supply voltage: 220V/240V 1F 50 Hz
  • Specific model compatibility (all 230V 1F):
    • E.P. ADRM10/55: 0.55 kW (0.75 Hp), 2.5-4 A
    • E.P. ADRM10/75: 0.75 kW (1 Hp), 4-6.3 A
    • E.P. ADRM10/110: 1.1 kW (1.5 Hp), 6.3-10 A
    • E.P. ADRM10/150: 1.5 kW (2 Hp), 10-16 A
    • E.P. ADRM20/55: 2x0.55 kW (2x0.75 Hp), 2.5-4 A
    • E.P. ADRM20/75: 2x0.75 kW (2x1 Hp), 4-6.3 A
    • E.P. ADRM20/110: 2x1.1 kW (2x1.5 Hp), 6.3-10 A
    • E.P. ADRM20/150: 2x1.5 kW (2x2 Hp), 10-16 A
  • Examples of compatible electric pumps (for ADRM10/55 model): DRENOX OMNIA, PRIOX MINIVORT P, MINIVORT PP.

Mechanical

  • External dimensions: 220 - 270 - 185 mm
  • Weight:
    • ADRM 10: 5.5 kg
    • ADRM 20: 7.5 kg

Features & Operation

  • Main Components:
    • IP 54 plastic enclosure
    • Main switch
    • Fuse holder with fuses for electric pump
    • Fuse holder with fuses for auxiliary circuit
    • Transformer for auxiliary circuit
    • Terminal board for level control devices
    • Cable clamp
    • Contactor with thermal relay
  • Indicator LEDs:
    • Line ON indicator led
    • Pump running indicator led
    • Thermal cutout trip led
  • Operation Modes:
    • Manual via MAN/AUT selector
    • Automatic via float switch

Optional Accessories

  • UZA00200 Visual and acoustic alarm
  • CE040030 fins for wall mounting
  • Floats (see relative table in official PDF)
  • Electronic signaling and control board

Disclaimer: This summary is based on extracted text and may miss figures, footnotes, or revisions present in the full OEM PDF. Contractual data must always match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.