Nocchi Biox-XS
PDF datasheet mirror for Nocchi Biox-XS (Nocchi Pumps). Verify with OEM before design.
Summary
Product identification
NOCCHI BIOX XS series electric submersible vortex pumps are designed for sewage works. They are constructed entirely from AISI 304 stainless steel and operate fully immersed in the pumped liquid, which provides motor cooling. The pumps feature a retracted impeller and vortex operation. Automatic versions are equipped with a float switch.
Applications
- Lifting and draining waste water with suspended solid bodies.
- Lifting stations with one or more pumps for agricultural and civil complexes.
- Draining off infiltration water.
- Handling of sewage water (hygiene facilities), emptying of cess pits, and drainage into sewage works.
Operating limits
- Maximum liquid temperature: 40°C
- Maximum immersion below water level: 7 m
- Free transit of solid bodies: 40 mm
Materials of construction
- Pump body: Stainless steel X5 CrNi 1810 (AISI 304)
- Suction base: Stainless steel X5 CrNi 1810 (AISI 304)
- Impeller: Cast stainless steel X5 CrNi 1810 (AISI 304)
- Motor shaft: Stainless steel X5 CrNiS 1809 (AISI 416)
- Mechanical gasket: Silicon carbide
- Counterface: Silicon carbide (lubricated in oil chamber)
- Secondary seal: Lip seal in rubber NBR
- Sand-proof guard: Rubber NBR
- Delivery port: Threaded
Motor and electrical data
- Motor type: Dry motor
- Protection rating: IP 68
- Insulation class: F
- Power supply: Single phase with permanently activated capacitor and thermal cutout protection incorporated in the motor winding.
- Cable connection: Fully insulated chamber.
- Bearings: Self-lubricating ball bearings.
- Rotation speed: 2850 rpm
- Power cable: 10 m H07 RN-F with plug
Electrical specifications by model
- BIOX 250/9 XS AUT:
- Voltage: 1 ~ 230 V
- Current (In): 4.1 A
- Capacitor (μF): 12.5
- BIOX 350/11 XS AUT:
- Voltage: 1 ~ 230 V
- Current (In): 5.8 A
- Capacitor (μF): 20
Performance data
The hydraulic performance is characterized by a retracted impeller and vortex operation. A performance graph showing Q[m³/h] / Q[l/min] versus H[m] is available in the official PDF.
Performance table by model
- BIOX 250/9 XS AUT:
- Motor output (P2): 0.8 HP / 0.6 kW
- Motor power (P1): 1.2 HP / 0.9 kW
- Flow (Q) L/min: 50, 100, 150, 200, 250
- Flow (Q) m³/h: 3, 6, 9, 12, 15
- Head (H) m.c.a. / m.w.c.: 8, 6.6, 5.1, 3.4, 1.6
- BIOX 350/11 XS AUT:
- Motor output (P2): 1.2 HP / 0.9 kW
- Motor power (P1): 1.7 HP / 1.3 kW
- Flow (Q) L/min: 50, 100, 150, 200, 250, 300, 350
- Flow (Q) m³/h: 3, 6, 9, 12, 15, 18, 21
- Head (H) m.c.a. / m.w.c.: 9.6, 8.5, 7.3, 6, 4.5, 3, 1.5
Dimensions and weights
Dimensions are provided in millimeters (mm).
Dimensions and weights by model
- BIOX 250/9 XS AUT:
- A: 389 mm
- B: 196 mm
- C: 96 mm
- D: 168 mm
- DNM: 1”1/2 GAS
- H1: 250 mm
- H2: 370 mm
- Weight: 9.8 kg
- BIOX 350/11 XS AUT:
- A: 419 mm
- B: 196 mm
- C: 96 mm
- D: 168 mm
- DNM: 2” GAS
- H1: 300 mm
- H2: 400 mm
- Weight: 11.2 kg