Datasheet summary
Nocchi EasyBoost
PDF datasheet mirror for Nocchi EasyBoost (Nocchi Pumps). Verify with OEM before design.
Summary
Product Identification
The Nocchi EASYBOOST units are compact, robust, and reliable systems designed for automatic pressure boosting in water distribution networks. Each unit comprises:
- 2 electric pumps
- Electrical panel
- Base
- Suction and delivery manifolds
- Pressure switches
- Pressure gauge
- Delivery check valve
The pumps are controlled by two adjustable pressure switches connected to an electronic board, enabling sequential start-up, inversion of start-up sequence, dry-running protection, and timer settings.
Operating Limits
- Number of Pumps: 2
- Maximum Flow Rate (General Range):
- 200 to 360 L/min
- 12 to 21.6 m³/h
- Maximum Operating Pressure:
- CB, MULTINOX-XC, MULTINOX-A, MULTINOX-VE: 9 bar
- DHR: 12 bar
- VLR 2B: 10 bar
- VLR 4: 16 bar
- Ambient Temperature: Up to +40°C (for CB models) or +50°C (for other models).
Electrical
- Power Supply Voltage: 1
230 V / 3400 V - Frequency: 50 Hz
- Control Panel Protection Rating:
- Single Phase Electrical Panel: IP65 plastic enclosure
- Three Phase Electrical Panel: IP54 plastic enclosure
- Electric Pump Protection Rating:
- IP44 (for CB models)
- IP55 (for MULTINOX-XC, MULTINOX-A, MULTINOX-VE, DHR, VLR 2B, VLR 4 models)
- Control Panel Features:
- Fuses
- Multi-function electronic board with integrated transformer for auxiliary circuit
- Start-up relay for each pump
- Overload protection by means of electronic board
- Trimmer to set delay time from 0 to 180 seconds after pressure switch contact opens (for each pump)
- Main Functions:
- Sequential inversion of pump start-up at the end of each work cycle.
- ON/OFF control of tank level (first collection) or supply pipeline pressure via float switch or differential pressure switch.
- Settable pump timer.
- Signals and Controls (Single Phase Electrical Panel):
- Manual-Automatic button
- ON/OFF buttons for each pump
- Power ON indicator LED
- Pump running indicator LED
- Indicator LED to signal low level in tank on first collection or low pressure on suction manifold.
- Manual/Automatic mode indicator LEDs
- BMS with contacts for each pump indicating pump running and pump overload.
- Signals and Controls (Three Phase Electrical Panel):
- M-0-T button (Manual - 0 - Automatic)
- ON/OFF buttons for each pump
- Power ON indicator LED
- Pump running indicator LED
- Indicator LED to signal low level in tank on first collection or low pressure on suction manifold.
- Overload indicator LED
- Manual/Automatic mode indicator LEDs
- BMS with contacts for each pump indicating pump running, pump overload, and water supply failure.
- RS232/RS485 communication.
Mechanical / Hydraulic
- Base: Galvanized sheet steel
- Suction Manifold Components:
- 2 brass ball valves
- 1 water filling hose
- Delivery Manifold Components:
- 2 brass ball valves
- 2 check valves
- 1 pressure gauge
- 2 pressure switches
- Electric Pump Types:
- CB: Twin impeller centrifugal on horizontal axis.
- MULTINOX XC: Multi-cell centrifugal on horizontal axis.
- MULTINOX A: Multi-cell self-priming centrifugal on horizontal axis.
- MULTINOX VE: Multi-cell centrifugal on vertical axis.
- DHR: Multi-cell centrifugal on vertical axis.
- VLR: Multi-cell centrifugal on vertical axis.
- Pipe Connections: Typically 1-1/2" or 2" for suction and delivery, varying by model.
Hydraulic Performance, Dimensions, and Weights
Detailed performance tables, overall dimensions, and weights are available for various EASYBOOST models (including MULTINOX-XC, MULTINOX-A, CB, DHR 2/4, DHR 9, MULTINOX-VE, VLR 2B, and VLR 4 pump configurations). See the official PDF for exact tabulated values.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF. Contractual data must always match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.