Back to Nocchi Pumps
Pentair logo

Datasheet summary

Nocchi Fluss Control

PDF datasheet mirror for Nocchi Fluss Control (Nocchi Pumps). Verify with OEM before design.

Summary

Product identification

  • NOCCHI ELECTRONIC PRESSURE REGULATOR FOR SINGLE PHASE PUMPS
  • Model: FLUSSCONTROL

Overview and Features

This device controls the start-up and shutdown of the pump based on valve opening and closing. It protects the pump from dry running by blocking it in the event of no flow on intake. After a flow failure, normal operation can be restored by pressing the red Restart button. The unit restarts automatically after a temporary power failure.

Advantages:

  • Elimination of water hammer effect.
  • Replaces traditional expansion tank system.
  • Maintenance free.
  • Protection in event of water supply failure.
  • Simple to install.
  • Pressure remains constant during delivery.

Applications:

  • For the start-up and shutdown of surface or submersible single phase pumps.
  • Maintains constant pressure during delivery.
  • Starts and stops the pump according to opening and closing of utilities.

Electrical

  • Electric power supply: 230 V single phase
  • Frequency: 50-60 Hz
ParameterFlusscontrolFlusscontrol basic
Maximum current16 (8) A16 (6) A
Max. nominal pump power1.5 kW (2 HP)1.1 kW

Operating limits

ParameterFlusscontrolFlusscontrol basic
Maximum pressure10 bar8 bar
Maximum liquid temperature65° C60° C
Maximum ambient temperature40° C40° C

Mechanical / hydraulic

ParameterFlusscontrolFlusscontrol basic
Protection ratingIP 65IP 65
Pressure drop with 6 m³/h flow rate0.95 bar1.1 bar
Weight1.07 Kg0.8 Kg

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror