Datasheet summary
Pedrollo VSP
PDF datasheet mirror for Pedrollo VSP (Pedrollo Pumps). Verify with OEM before design.
Summary
Product Identification
The VSP is a versatile pumping unit designed for various applications, including residential and commercial use for water supply and pressure boosting. It comprises a pump and an integrated frequency converter, ensuring constant pressure despite fluctuating water demand.
The VSP system is available in several product lines:
- VSP-FCR
- VSP-PLURIJET
- VSP-MK
- VSP-HT-PRO
Overview
The VSP is a ready-to-use system that integrates seamlessly with new or existing pressurization systems, offering enhanced comfort and significant energy savings. It features a display and keypad for simple and intuitive configuration, viewing operating parameters, and alarm messages. An advanced menu is available for modifying factory parameters to adapt to specific plant conditions.
Key Features
- Easy installation, configuration, and adjustment.
- Optimized performance and low noise levels for greater comfort.
- Energy saving through reduced startup and operating currents.
- Automatic compensation for fluctuations in the supply voltage.
- Communication with another device to enhance system capabilities (RS 485).
- Intelligent management of control and intervention in case of anomalies.
- PFC technology maintains hydraulic performance even when supply voltages vary within ±20% of the nominal value.
Electrical
- Power supply:
- Single-phase: 1~ 230V±10%
- Three-phase: 3~ 400V±10%
- Frequency: 50/60 Hz
- Integrated protection against:
- Dry running
- Overcurrent
- Overvoltage and undervoltage
- Combustion chamber
- Short circuit
- Lack of phases in the connections (for three-phase version)
Operating Limits
The VSP is designed for clean water applications. For specific liquid temperature, ambient temperature, and protection degree, please refer to the technical data of the specific electropumps in the official PDF.
Performance Data (50 Hz)
The VSP series offers a range of models with varying power, absorption, and performance characteristics, including adjustable set points for pressure and flow.
VSP-FCR / VSP-PLURIJET Series
These series share identical performance specifications.
Single-phase 230 V models:
- VSPm - FCR/PLURIJET 75/90: 1.5 kW (2 HP), 9.8 A. Flow (Q) 5 – 90 litres/min, Head (H) 71.5 – 43.5 metres. Adjustable Set Point Min 1.9 bar (5 – 60 l/min), Calibration Std 4.0 bar (5 – 86 l/min), Max 7.0 bar (5 – 16 l/min).
- VSPm - FCR/PLURIJET 80/130: 1.5 kW (2 HP), 9.8 A. Flow (Q) 5 – 130 litres/min, Head (H) 74.5 – 30 metres. Adjustable Set Point Min 2.0 bar (5 – 107 l/min), Calibration Std 4.0 bar (5 – 107 l/min), Max 7.3 bar (5 – 22 l/min).
- VSPm - FCR/PLURIJET 70/200: 1.5 kW (2 HP), 9.8 A. Flow (Q) 5 – 200 litres/min, Head (H) 65.5 – 21 metres. Adjustable Set Point Min 1.8 bar (5 – 180 l/min), Calibration Std 4.0 bar (5 – 115 l/min), Max 6.4 bar (5 – 36 l/min).
Three-phase 400 V models:
- VSP - FCR/PLURIJET 75/90: 1.5 kW (2 HP), 3.6 A. Flow (Q) 5 – 90 litres/min, Head (H) 71.5 – 43.5 metres. Adjustable Set Point Min 1.9 bar (5 – 60 l/min), Calibration Std 4.0 bar (5 – 86 l/min), Max 7.0 bar (5 – 16 l/min).
- VSP - FCR/PLURIJET 100/90: 2.2 kW (3 HP), 4.9 A. Flow (Q) 5 – 90 litres/min, Head (H) 94 – 62.5 metres. Adjustable Set Point Min 2.5 bar (5 – 58 l/min), Calibration Std 4.0 bar (5 – 71 l/min), Max 9.2 bar (5 – 20 l/min).
- VSP - FCR/PLURIJET 80/130: 1.5 kW (2 HP), 3.6 A. Flow (Q) 5 – 130 litres/min, Head (H) 74.5 – 30 metres. Adjustable Set Point Min 2.0 bar (5 – 107 l/min), Calibration Std 4.0 bar (5 – 107 l/min), Max 7.3 bar (5 – 22 l/min).
- VSP - FCR/PLURIJET 105/130: 2.2 kW (3 HP), 4.9 A. Flow (Q) 5 – 130 litres/min, Head (H) 98 – 57.5 metres. Adjustable Set Point Min 2.7 bar (5 – 90 l/min), Calibration Std 4.0 bar (5 – 107 l/min), Max 9.6 bar (5 – 30 l/min).
- VSP - FCR/PLURIJET 70/200: 1.5 kW (2 HP), 3.6 A. Flow (Q) 5 – 200 litres/min, Head (H) 65.5 – 21 metres. Adjustable Set Point Min 1.8 bar (5 – 180 l/min), Calibration Std 4.0 bar (5 – 115 l/min), Max 6.4 bar (5 – 36 l/min).
- VSP - FCR/PLURIJET 95/200: 2.2 kW (3 HP), 4.9 A. Flow (Q) 5 – 200 litres/min, Head (H) 87.5 – 42 metres. Adjustable Set Point Min 2.4 bar (5 – 178 l/min), Calibration Std 4.0 bar (5 – 175 l/min), Max 8.6 bar (5 – 32 l/min).
VSP-MK Series
Single-phase 230 V models:
- VSPm - MK 3/3: 0.75 kW (1 HP), 6.2 A. Flow (Q) 10 – 80 litres/min, Head (H) 52 – 29 metres. Adjustable Set Point Min 1.4 bar (5 – 52 l/min), Calibration Std 4.0 bar (5 – 52 l/min), Max 5.0 bar (5 – 14 l/min).
- VSPm - MK 3/5: 1.1 kW (1.5 HP), 7.8 A. Flow (Q) 10 – 80 litres/min, Head (H) 85 – 48 metres. Adjustable Set Point Min 2.3 bar (5 – 52 l/min), Calibration Std 4.0 bar (5 – 72 l/min), Max 8.3 bar (5 – 13 l/min).
- VSPm - MK 3/6: 1.5 kW (2 HP), 9.0 A. Flow (Q) 10 – 80 litres/min, Head (H) 101 – 56 metres. Adjustable Set Point Min 2.7 bar (5 – 53 l/min), Calibration Std 4.0 bar (5 – 65 l/min), Max 9.7 bar (5 – 19 l/min).
- VSPm - MK 5/4: 0.75 kW (1 HP), 6.4 A. Flow (Q) 20 – 120 litres/min, Head (H) 55 – 20 metres. Adjustable Set Point Min 1.5 bar (5 – 101 l/min), Calibration Std 4.0 bar (5 – 82 l/min), Max 5.3 bar (5 – 26 l/min).
- VSPm - MK 5/5: 1.1 kW (1.5 HP), 6.5 A. Flow (Q) 20 – 120 litres/min, Head (H) 69 – 21.5 metres. Adjustable Set Point Min 1.8 bar (5 – 108 l/min), Calibration Std 4.0 bar (5 – 99 l/min), Max 6.7 bar (5 – 13 l/min).
- VSPm - MK 5/7: 1.5 kW (2 HP), 9.0 A. Flow (Q) 20 – 120 litres/min, Head (H) 95 – 30 metres. Adjustable Set Point Min 2.6 bar (5 – 109 l/min), Calibration Std 4.0 bar (5 – 111 l/min), Max 9.3 bar (5 – 16 l/min).
- VSPm - MK 8/4: 1.1 kW (1.5 HP), 8.3 A. Flow (Q) 40 – 180 litres/min, Head (H) 53 – 12 metres. Adjustable Set Point Min 1.4 bar (5 – 175 l/min), Calibration Std 4.0 bar (5 – 115 l/min), Max 5.2 bar (5 – 30 l/min).
- VSPm - MK 8/5: 1.5 kW (2 HP), 10.0 A. Flow (Q) 40 – 180 litres/min, Head (H) 68 – 15.5 metres. Adjustable Set Point Min 1.8 bar (5 – 175 l/min), Calibration Std 4.0 bar (5 – 138 l/min), Max 6.6 bar (5 – 45 l/min).
Three-phase 400 V models:
- VSP - MK 3/3: 0.75 kW (1 HP), 1.7 A. Flow (Q) 10 – 80 litres/min, Head (H) 52 – 29 metres. Adjustable Set Point Min 1.4 bar (5 – 52 l/min), Calibration Std 4.0 bar (5 – 52 l/min), Max 5.0 bar (5 – 14 l/min).
- VSP - MK 3/5: 1.1 kW (1.5 HP), 2.3 A. Flow (Q) 10 – 80 litres/min, Head (H) 85 – 48 metres. Adjustable Set Point Min 2.3 bar (5 – 52 l/min), Calibration Std 4.0 bar (5 – 72 l/min), Max 8.3 bar (5 – 13 l/min).
- VSP - MK 3/6: 1.5 kW (2 HP), 2.8 A. Flow (Q) 10 – 80 litres/min, Head (H) 101 – 56 metres. Adjustable Set Point Min 2.7 bar (5 – 53 l/min), Calibration Std 4.0 bar (5 – 65 l/min), Max 9.7 bar (5 – 19 l/min).
- VSP - MK 5/4: 0.75 kW (1 HP), 2.0 A. Flow (Q) 20 – 120 litres/min, Head (H) 55 – 20 metres. Adjustable Set Point Min 1.5 bar (5 – 101 l/min), Calibration Std 4.0 bar (5 – 82 l/min), Max 5.3 bar (5 – 26 l/min).
- VSP - MK 5/5: 1.1 kW (1.5 HP), 2.2 A. Flow (Q) 20 – 120 litres/min, Head (H) 69 – 21.5 metres. Adjustable Set Point Min 1.8 bar (5 – 108 l/min), Calibration Std 4.0 bar (5 – 99 l/min), Max 6.7 bar (5 – 13 l/min).
- VSP - MK 5/7: 1.5 kW (2 HP), 3.0 A. Flow (Q) 20 – 120 litres/min, Head (H) 95 – 30 metres. Adjustable Set Point Min 2.6 bar (5 – 109 l/min), Calibration Std 4.0 bar (5 – 111 l/min), Max 9.3 bar (5 – 16 l/min).
- VSP - MK 5/8: 2.2 kW (3 HP), 3.5 A. Flow (Q) 20 – 120 litres/min, Head (H) 108 – 34 metres. Adjustable Set Point Min 2.9 bar (5 – 109 l/min), Calibration Std 4.0 bar (5 – 115 l/min), Max 10.6 bar (5 – 14 l/min).
- VSP - MK 8/4: 1.1 kW (1.5 HP), 2.8 A. Flow (Q) 40 – 180 litres/min, Head (H) 53 – 12 metres. Adjustable Set Point Min 1.4 bar (5 – 175 l/min), Calibration Std 4.0 bar (5 – 115 l/min), Max 5.2 bar (5 – 30 l/min).
- VSP - MK 8/5: 1.5 kW (2 HP), 3.4 A. Flow (Q) 40 – 180 litres/min, Head (H) 68 – 15.5 metres. Adjustable Set Point Min 1.8 bar (5 – 175 l/min), Calibration Std 4.0 bar (5 – 138 l/min), Max 6.6 bar (5 – 45 l/min).
- VSP - MK 8/6: 2.2 kW (3 HP), 3.8 A. Flow (Q) 40 – 180 litres/min, Head (H) 81 – 18.5 metres. Adjustable Set Point Min 2.2 bar (5 – 175 l/min), Calibration Std 4.0 bar (5 – 149 l/min), Max 8.0 bar (5 – 22 l/min).
VSP-HT-PRO Series
Single-phase 230 V models:
- VSPm - HT 3/4 PRO: 0.75 kW (1 HP), 7.5 A. Flow (Q) 5 – 90 litres/min, Head (H) 65 – 35 metres. Adjustable Set Point Min 1.6 bar (5 – 59 l/min), Calibration Std 4.0 bar (5 – 73 l/min), Max 5.9 bar (5 – 19 l/min).
- VSPm - HT 3/5 PRO: 1.1 kW (1.5 HP), 9.0 A. Flow (Q) 5 – 90 litres/min, Head (H) 80 – 44 metres. Adjustable Set Point Min 2.0 bar (5 – 62 l/min), Calibration Std 4.0 bar (5 – 86 l/min), Max 7.4 bar (5 – 22 l/min).
- VSPm - HT 3/6 PRO: 1.5 kW (2 HP), 10.5 A. Flow (Q) 5 – 90 litres/min, Head (H) 96 – 52 metres. Adjustable Set Point Min 2.4 bar (5 – 62 l/min), Calibration Std 4.0 bar (5 – 84 l/min), Max 8.8 bar (5 – 20 l/min).
- VSPm - HT 5/2 PRO: 0.75 kW (1 HP), 7.0 A. Flow (Q) 5 – 130 litres/min, Head (H) 35 – 20.5 metres. Adjustable Set Point Min 0.8 bar (5 – 83 l/min), Calibration Std 2.0 bar (5 – 114 l/min), Max 3.1 bar (5 – 22 l/min).
- VSPm - HT 5/3 PRO: 1.1 kW (1.5 HP), 8.0 A. Flow (Q) 5 – 130 litres/min, Head (H) 51.5 – 31 metres. Adjustable Set Point Min 1.3 bar (5 – 91 l/min), Calibration Std 4.0 bar (5 – 71 l/min), Max 4.8 bar (5 – 14 l/min).
- VSPm - HT 5/4 PRO: 1.5 kW (2 HP), 9.5 A. Flow (Q) 5 – 130 litres/min, Head (H) 68.5 – 41 metres. Adjustable Set Point Min 1.7 bar (5 – 90 l/min), Calibration Std 4.0 bar (5 – 108 l/min), Max 6.1 bar (5 – 26 l/min).
- VSPm - HT 8/3 PRO: 1.1 kW (1.5 HP), 8.5 A. Flow (Q) 20 – 200 litres/min, Head (H) 46.5 – 17 metres. Adjustable Set Point Min 1.1 bar (5 – 182 l/min), Calibration Std 4.0 bar (5 – 58 l/min), Max 4.1 bar (5 – 28 l/min).
- VSPm - HT 8/4 PRO: 1.5 kW (2 HP), 10.0 A. Flow (Q) 20 – 200 litres/min, Head (H) 62 – 23 metres. Adjustable Set Point Min 1.5 bar (5 – 180 l/min), Calibration Std 4.0 bar (5 – 128 l/min), Max 5.4 bar (5 – 48 l/min).
Three-phase 400 V models:
- VSP - HT 3/4 PRO: 0.75 kW (1 HP), 2.5 A. Flow (Q) 5 – 90 litres/min, Head (H) 65 – 35 metres. Adjustable Set Point Min 1.6 bar (5 – 59 l/min), Calibration Std 4.0 bar (5 – 73 l/min), Max 5.9 bar (5 – 19 l/min).
- VSP - HT 3/5 PRO: 1.1 kW (1.5 HP), 3.0 A. Flow (Q) 5 – 90 litres/min, Head (H) 80 – 44 metres. Adjustable Set Point Min 2.0 bar (5 – 62 l/min), Calibration Std 4.0 bar (5 – 86 l/min), Max 7.4 bar (5 – 22 l/min).
- VSP - HT 3/6 PRO: 1.5 kW (2 HP), 3.5 A. Flow (Q) 5 – 90 litres/min, Head (H) 96 – 52 metres. Adjustable Set Point Min 2.4 bar (5 – 62 l/min), Calibration Std 4.0 bar (5 – 84 l/min), Max 8.8 bar (5 – 20 l/min).
- VSP - HT 3/7 PRO: 1.8 kW (2.5 HP), 4.2 A. Flow (Q) 5 – 90 litres/min, Head (H) 112 – 61 metres. Adjustable Set Point Min 2.8 bar (5 – 62 l/min), Calibration Std 4.0 bar (5 – 76 l/min), Max 10.2 bar (5 – 25 l/min).
- VSP - HT 5/2 PRO: 0.75 kW (1 HP), 2.3 A. Flow (Q) 5 – 130 litres/min, Head (H) 35 – 20.5 metres. Adjustable Set Point Min 0.8 bar (5 – 83 l/min), Calibration Std 2.0 bar (5 – 114 l/min), Max 3.1 bar (5 – 22 l/min).
- VSP - HT 5/3 PRO: 1.1 kW (1.5 HP), 2.4 A. Flow (Q) 5 – 130 litres/min, Head (H) 51.5 – 31 metres. Adjustable Set Point Min 1.3 bar (5 – 91 l/min), Calibration Std 4.0 bar (5 – 71 l/min), Max 4.8 bar (5 – 14 l/min).
- VSP - HT 5/4 PRO: 1.5 kW (2 HP), 3.2 A. Flow (Q) 5 – 130 litres/min, Head (H) 68.5 – 41 metres. Adjustable Set Point Min 1.7 bar (5 – 90 l/min), Calibration Std 4.0 bar (5 – 108 l/min), Max 6.1 bar (5 – 26 l/min).
- VSP - HT 5/5 PRO: 1.8 kW (2.5 HP), 4.0 A. Flow (Q) 5 – 130 litres/min, Head (H) 85 – 51.5 metres. Adjustable Set Point Min 2.1 bar (5 – 91 l/min), Calibration Std 4.0 bar (5 – 128 l/min), Max 7.5 bar (5 – 42 l/min).
- VSP - HT 5/6 PRO: 2.2 kW (3 HP), 4.3 A. Flow (Q) 5 – 130 litres/min, Head (H) 103 – 62 metres. Adjustable Set Point Min 2.6 bar (5 – 92 l/min), Calibration Std 4.0 bar (5 – 118 l/min), Max 9.3 bar (5 – 25 l/min).
- VSP - HT 8/3 PRO: 1.1 kW (1.5 HP), 3.0 A. Flow (Q) 20 – 200 litres/min, Head (H) 46.5 – 17 metres. Adjustable Set Point Min 1.1 bar (5 – 182 l/min), Calibration Std 4.0 bar (5 – 58 l/min), Max 4.1 bar (5 – 28 l/min).
- VSP - HT 8/4 PRO: 1.5 kW (2 HP), 3.4 A. Flow (Q) 20 – 200 litres/min, Head (H) 62 – 23 metres. Adjustable Set Point Min 1.5 bar (5 – 180 l/min), Calibration Std 4.0 bar (5 – 128 l/min), Max 5.4 bar (5 – 48 l/min).
- VSP - HT 8/5 PRO: 1.8 kW (2.5 HP), 4.0 A. Flow (Q) 20 – 200 litres/min, Head (H) 77.5 – 28.5 metres. Adjustable Set Point Min 1.8 bar (5 – 181 l/min), Calibration Std 4.0 bar (5 – 156 l/min), Max 6.7 bar (5 – 44 l/min).
- VSP - HT 8/6 PRO: 2.2 kW (3 HP), 4.5 A. Flow (Q) 20 – 200 litres/min, Head (H) 93 – 34.5 metres. Adjustable Set Point Min 2.3 bar (5 – 186 l/min), Calibration Std 4.0 bar (5 – 179 l/min), Max 8.2 bar (5 – 32 l/min).
Mechanical / Hydraulic
Ports
- VSP-FCR / VSP-PLURIJET Series:
- DN1: 1¼"
- DN2: 1"
- VSP-MK Series:
- DN1: 1¼"
- DN2: 1"
- VSP-HT-PRO Series:
- HT 3 models: DN1: 1", DN2: 1"
- HT 5 models: DN1: 1¼", DN2: 1¼"
- HT 8 models: DN1: 1½", DN2: 1½"
Dimensions and Weight
Dimensions (f, a, w, h, h1, h2, t, t1, t2, n, n1, s for FCR/PLURIJET; a, c, h, h1, h2, t, t1, t2, n1, n2, S1, s2 for MK; a, b, c, d, h, h1, n1, n2, m for HT-PRO) and weights vary significantly by model and phase configuration.
See the official PDF for exact tabulated values.
Disclaimer: This summary is based on extracted text and may miss figures, footnotes, or the latest revisions. Contractual data must always match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.