Back to Pentair STA-RITE
Pentair logo

Datasheet summary

CM Series Horizontal Centrifugal pumps

PDF datasheet mirror for CM Series Horizontal Centrifugal pumps (Pentair STA-RITE). Verify with OEM before design.

Summary

Product identification

The CM series consists of single impeller horizontal centrifugal pumps.

Applications

  • Lifting from wells for irrigation
  • Pressurization systems
  • Autoclaves for homes
  • Washing

Operating limits

  • Maximum liquid temperature: 90°C (50°C for model CM 90/22)
  • Maximum recommended suction height: 5 m with foot valve
  • Maximum operating pressure:
    • 6 bar for models HP 0.5
    • 8 bar for models HP 1 - 1.5 - 2
  • Continuous service

Feed water

  • Type of liquid: Clear or slightly turbid non-abrasive water

Electrical

  • Motor type: Closed, ventilated from outside
  • Degree of protection: IP 44
  • Insulation class: F
  • Single-phase power supply: With capacitor permanently on and thermal protection built into the motor casing
  • Three-phase power supply: Requires external protection provided by the user
  • Speed of rotation: 2850 rpm

Mechanical / hydraulic

The pumps are described as highly reliable, sturdy, and offering high hydraulic performance, operating silently.

Table of Materials:

  • Pump body: Cast iron EN GJL 200
  • Motor casing: Cast iron EN GJL 200
  • Impeller: Brass (CM 90/22 in technopolymer)
  • Motor shaft: Stainless steel X 12 CrNiS 1809 (AISI 416)
  • Mechanical seal: Graphite
  • Counterface: Ceramic
  • Gaskets: NBR 70 shore

Hydraulic Performance: Performance curves are provided in the source document, showing Head (H[m]) versus Flow Rate (Q[m³/h] and Q[l/min]) for models 90/22, 100/36, 110/44, and 130/51. Efficiency (η[%]) curves are also shown. See the official PDF for exact tabulated values and performance curves.

Performance Table: The performance table details various models (CM 90/22 M/T, CM 100/36 M/T, CM 110/44 M/T, CM 130/51 M/T) with their respective motor powers (P2 in HP/kW, P1 in HP/kW), voltage (V), current (In A), capacitor (μF), and head (m.c.a. / m.c.w.) at different flow rates (Q in l/min and m³/h). Model CM 90/22 uses a technopolymer impeller. See the official PDF for exact tabulated values.

Overall Dimensions and Weights: Dimensions (A, B, C, D, E, F, h1, h2 in mm), inlet (DNA) and outlet (DNM) connections, and weights (Kg) are provided for each model (CM 90/22, CM 100/36, CM 110/44, CM 130/51).

  • Inlet/Outlet Connections: 1" for CM 90/22 and CM 100/36; 1"1/4 inlet and 1" outlet for CM 110/44 and CM 130/51. See the official PDF for exact tabulated dimensions and weights.

Disclaimer This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used for the project.