
Datasheet summary
Projet SN Series Self Priming Well Jet Pump
PDF datasheet mirror for Projet SN Series Self Priming Well Jet Pump (Pentair STA-RITE). Verify with OEM before design.
Summary
Product Identification
The STA-RITE® ProJet™ SN Series are cast iron, self-priming shallow well jet pumps designed for water systems and sprinkling in homes, farms, and cottages. They provide excellent performance with good pressure for wells up to 25' deep. The pumps are self-priming after the priming chamber has been filled with water.
Available models include:
- SNC-HF25L
- SNC
- SND
- SNE
- SNF
Operating Limits
- Max. Liquid Temperature: 140°F
- Max. Inlet Pressure: 50 PSI
- Maximum well depth: 25'
Average Priming Time (in minutes):
- At 15 Feet:
- SNC: 2.3
- SND: 1.7
- SNE: 1.3
- SNF: 1.1
- At 25 Feet:
- SNC: 6.4
- SND: 4.4
- SNE: 4.4
- SNF: 2.6
Electrical
- Motor Voltage: 115/230 V (all models)
- Pressure Switch Setting:
- SNC-HF25L: 20-40 PSI
- SNC, SND, SNE, SNF: 30-50 PSI
- Certifications: UL778/CSA108
Horsepower (HP) by model:
- SNC-HF25L: 1/2 HP
- SNC: 1/2 HP
- SND: 3/4 HP
- SNE: 1 HP
- SNF: 1-1/2 HP
Mechanical / Hydraulic
Construction Materials:
- Body: Close-grained cast iron
- Nozzle: High-strength Lexan®
- Venturi: Lexan®
- Impeller: Noryl®
- Diffuser: Reinforced polypropylene
- Shaft: One-piece threaded, 416 grade stainless steel
- Base: Steel, 12 gauge
- Pump and Motor Shaft: Stainless steel
- Mechanical Shaft Seal: Precision lapped and highly polished carbon-ceramic, stainless steel construction.
Pipe Tapping Sizes:
- Suction: 1-1/4" NPT
- Discharge: 1" NPT
Approximate Weight (LBS):
- SNC-HF25L: 45
- SNC: 45
- SND: 47
- SNE: 55
- SNF: 60
Outline Dimensions (in inches):
- SNC: L 18.7, B 7.1
- SND: L 18.7, B 7.1
- SNE: L 21.3, B 7.0
- SNF: L 22.4, B 8.0
- Note: Dimensions are for estimating purposes only. See the official PDF for detailed diagrams.
Pump Performance: Detailed pump performance data (Capacity in gallons per minute, Discharge Pressure PSI, Dynamic Suction Lift, Shut-off Pressure PSI) is available in tabulated form for each model. See the official PDF for exact tabulated values.
Relief Valve Requirements:
- Pumps installed with a Pro-Source® tank require a 100 PSI relief valve.
- Pumps installed with a conventional tank require a 75 PSI relief valve.
- The relief valve must be capable of relieving the entire flow of the pump at relief pressure.
Disclaimer
This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.