Summary

Product identification

  • dph(s)i horizontal stainless steel multi-stage centrifugal pump
  • Available in AISI 316 and AISI 304
  • Drinking water approvals (WRAS/ACS)
  • Certification and test certificates available upon request (e.g., LR, BV, ABS, DNV GL 2.1; 2.2; 3.1 and 3.2)

Operating limits

  • Temperature of the medium: -20°C up to +140°C
  • Max pressure class: PN25
  • 50 Hz operation:
    • Qmax: 22.5 m³/uur
    • Hmax: 136 mwc
  • 60 Hz operation:
    • Qmax: 26.3 m³/uur
    • Hmax: 195 mwc

Feed water

  • Suitable for drinking water applications (WRAS/ACS approved).

Electrical

  • Frequency: 50 Hz / 60 Hz
  • Phases: 1 and 3 phases
  • Motor types:
    • DPH(S)I 2, 4, and 6 available with 2-pole motor
    • DPH(S)I 10 and 15 with 2 or 4-pole motor
  • Efficiency: Standard IE3 (≥0.75 kW), optional IE4 or IE5
  • Max motor power: 7.5 kW
  • Also suitable for NEMA motor

Mechanical / hydraulic

  • Materials: AISI 316 and AISI 304 stainless steel
  • Optional low NPSHr package
  • Seal combinations: 10 options possible in accordance with EN12756 (Easy access and Cartridge)
  • Discharge connection: Optionally placed on the left, right, or top of the pump
  • Draining and sensor plugs: 2x2 plugs on each side of the casing for easy access
  • Suction and discharge connections:
    • Close to each other on the casing, 90° angle, in line with industry standard
    • Taper internal thread connection DIN-ISO 228-1
    • dph(s)i 2, 4, and 6: G 1 ¼
    • dph(s)i 10, 15: G2
  • Pump foot: Cast stainless steel

Applications

  • Industry – general
  • Water treatment
  • Pressure boosting systems
  • Hot water applications
  • Transportation of drinking water
  • Transportation of cooling water

Disclaimer