DPV Vertical centrifugal pumps
PDF datasheet mirror for DPV Vertical centrifugal pumps (Duijvelaar DP Pumps). Verify with OEM before design.
Summary
Product identification
The DPV series consists of vertical, multi-stage, centrifugal pumps designed and produced by DP-Pumps in Holland. These pumps feature a modular construction, allowing for customization to specific application requirements. The DPV range is available with a DP-label or can be private labeled.
Operating limits
- NPSH-level: 0.6 up to 4.6 m
- Medium Temperature Range: -20 up to +140° C
- Standard Pressure Durability: PN 40
- Pressure Classes: PN 16, 25, 40
Feed water / Product water
The DPV series is designed for reliable distribution and conservation of water quality, suitable for a wide range of media.
Typical Applications:
- Domestic water supply
- Utility
- Cooling water transport
- Hot water applications
- Fire fighting
- Food, chemical and process industry
- Irrigation
Electrical
- Motor Efficiency: IE2 (Standard high efficiency motor)
- Ingress Protection (IP): IP55
- Insulation Class: F
- Temperature Safeguard: PTC for motors ≥ 3 kW
- Voltage and Frequencies: Extensive choice available
- Motor Types: Can be equipped with various motor types, brands, or options, including standard DP motor, DP block-motor, Siemens motor, VEM motor, Explosion proof (EExe II and EExd II C Acc. II 2 G c T3-T4), and Marine motor.
Mechanical / hydraulic
The DPV pumps feature a unique hydraulic design for high pressure per impeller at high efficiency, with an overall efficiency up to 79%. They are constructed with corrosion-free, high-quality stainless steel (AISI 304 or 316) for the hydraulic assembly and shroud.
Key Features:
- Hydraulic Assembly: Highest efficiency in the market, made from high quality stainless steel AISI 304 or 316.
- Shaft Seal: Extensive choice of elastomers and 11 different shaft seals. Options include Fixed, Easy Access, and Cartridge seals, which are exchangeable without disassembling the pump.
- Pump Casing: Cast material, available in VC-design with rigid flanges, V and VS design with collar flanges, and E-design with built-in non return valve. Designed for draining without residue.
- Smart Plugs: Made of stainless steel AISI 304 or 316, for filling, draining, de-aerating, and measuring (∆p) suction and discharge pressure. By-pass possible with durable sealing.
- Solid Construction Shroud: Robust stainless steel housing, low vibration and noise.
- Solid Base Plate: Powder coated 100 μm (standard cast iron), with stainless steel as an optional material.
- Connections:
- Pressure classes: PN 16, 25, 40
- Material options: Stainless steel AISI 304 or 316
- Types: External thread with built-in non return valve, counter flange, victaulic, triclamp, round flange
- Standards: DIN, JIS, ASME
Performance Data (50Hz)
The DPV series offers a wide range of performance characteristics at 50Hz:
- Capacity Range: From 0.2 m³/h (DPV 2) up to 112.8 m³/h (DPV 85)
- Nominal Capacity at Qopt.: From 1.9 m³/h (DPV 2) up to 85.7 m³/h (DPV 85)
- Maximum Pump Pressure: From 58 m (DPV 10 4P) up to 256 m (DPV 6)
- Maximum Pressure at Qopt.: From 43 m (DPV 10 4P, DPV 15 4P) up to 200 m (DPV 6)
- NPSH at Qopt.: From 0.6 m (DPV 15 4P, DPV 40 4P) up to 3.0 m (DPV 25 2P)
- Maximum Efficiency: From 54% (DPV 2) up to 79% (DPV 85)
Performance Data (60Hz)
The DPV series offers a wide range of performance characteristics at 60Hz:
- Capacity Range: From 0.24 m³/h (DPV 2) up to 132 m³/h (DPV 85)
- Nominal Capacity at Qopt.: From 2.3 m³/h (DPV 2) up to 100 m³/h (DPV 85)
- Maximum Pump Pressure: From 57 m (DPV 15 4P) up to 255 m (DPV 6)
- Maximum Pressure at Qopt.: From 31 m (DPV 60 4P) up to 201 m (DPV 2)
- NPSH at Qopt.: From 0.9 m (DPV 40 4P, DPV 60 4P) up to 4.6 m (DPV 25 2P)
- Maximum Efficiency: From 54% (DPV 2) up to 79% (DPV 85)
Note: For detailed model-specific capacity, pressure, and NPSH values, please refer to the official PDF datasheet.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF. Contractual data for any project must always match the specific OEM PDF revision used for that project.