Datasheet summary
1300 Series
PDF datasheet mirror for 1300 Series (Lowara Pumps). Verify with OEM before design.
Summary
Product Identification
The Lowara 1300 Series is a range of 50 Hz submersible pumps designed for pure performance and value. The series includes both Non-clog and Vortex impeller types.
The product identification code follows a specific structure, for example: 1315M-100X.453.S20.400/10 indicates a 1315 electric pump series, Medium head, 100 mm nominal delivery port, Installation type X, 4 poles version, 50 Hz, three-phase, S20 Curve ID - Non-clog hydraulics, 400 V voltage, and 10 m cable length.
Key components of the identification code include:
- Pump series: 1305, 1310, 1315, 1320, 1325
- Model variant: L (Low head), M (Medium head), H (High head), S (Super high head)
- Outlet dimension (mm): 50, 65, 65-80, 80, 100, 150
- Phase: 1 (Single-phase), 3 (Three-phase)
- Number of poles: 2, 4, 6
- Frequency: 5 (50 Hz), 6 (60 Hz)
- Electrical Voltage: 230 V, 400 V, 415 V
- Performance curve n.: Sxx (Non-clog hydraulics), Vxx (Vortex hydraulics)
- Motor cable length: /10 (10 m), /20 (20 m)
- Installation type: W (Wet well installation), T (Free-standing threaded connection), H (Free-standing hose connection), X (To be completed with installation kit)
- Options: H (Handle), D (Leakage detector)
Applications
Lowara 1300 series pumps are ideal for sewage and surface wastewater within commercial building applications. They are suitable for:
- Domestic sewage pumping stations
- Wastewater pumping stations
- Stormwater pumping stations
- Drainage water
- Groundwater
The Non-clog series is designed for pumping clean water, surface water, and wastewater containing solids or long-fibred material. The Vortex impeller is noted as a good choice for low volume, high head applications, and media containing sand and other abrasive materials.
Operating Limits
For the 1300 Non-clog Series:
- Maximum liquid temperature: 40 °C
- Maximum immersion depth: 20 m
- pH pumped liquid: pH 5.5-14
- Maximum liquid density: 1100 Kg/m³
- Maximum number of starts per hour: 30 (for Non-clog series); generally, the pumps can handle 15 starts per hour without problem.
Mechanical / Hydraulic
The pumps feature a sturdy cast iron construction, self-cleaning impellers (Non-clog series), and a double mechanical seal (material varies by model). The hydraulic design is proven to reduce clogging and maintain efficiency.
The complete range offers various maximum flow rates, pressures, motor ratings, outlet sizes, and weights:
- 1305 Non-clog:
- Maximum flow: 14 l/s
- Maximum pressure: 17 m
- Motor Rating: 0.75 - 1.2 kW
- Outlet: 50 mm
- Weight: 32 - 34 kg
- 1305 Vortex:
- Maximum flow: 10 l/s
- Maximum pressure: 11 m
- Motor Rating: 0.75 - 1.2 kW
- Outlet: 50 mm
- Weight: 33 - 34 kg
- 1310 Non-clog:
- Maximum flow: 18 l/s
- Maximum pressure: 25 m
- Motor Rating: 1.4 - 2.4 kW
- Outlet: 50 - 80 mm
- Weight: 35 - 38 kg
- 1310 Vortex:
- Maximum flow: 16 l/s
- Maximum pressure: 16 m
- Motor Rating: 1.2 - 2.4 kW
- Outlet: 50 - 80 mm
- Weight: 35 - 41 kg
- 1315 Non-clog:
- Maximum flow: 54 l/s
- Maximum pressure: 30 m
- Motor Rating: 1.8 - 4.4 kW
- Outlet: 80 - 100 mm
- Weight: 80 - 84 kg
- 1315 Vortex:
- Maximum flow: 44 l/s
- Maximum pressure: 15 m
- Motor Rating: 2.2 - 4.4 kW
- Outlet: 65 - 100 mm
- Weight: 80 - 84 kg
- 1320 Non-clog:
- Maximum flow: 74 l/s
- Maximum pressure: 41 m
- Motor Rating: 3.5 - 7.5 kW
- Outlet: 80 - 100 mm
- Weight: 115 - 134 kg
- 1320 Vortex:
- Maximum flow: 54 l/s
- Maximum pressure: 29 m
- Motor Rating: 3.5 - 7.5 kW
- Outlet: 80 - 100 mm
- Weight: 125 - 134 kg
- 1325 Non-clog:
- Maximum flow: 115 l/s
- Maximum pressure: 63 m
- Motor Rating: 9 - 18 kW
- Outlet: 80 - 150 mm
- Weight: 164 - 179 kg
Overall specifications for the 1300 Non-clog Series:
- Delivery: up to 115 l/s
- Head: up to 63 m
- Discharge connection: DN 50, 65, 80, 100, 150 mm
Hydraulic performance tables are present in the official PDF but are unreadable in the extracted text. See the official PDF for exact tabulated values.
Dimensions and weights for specific models (e.g., 1305S, 1310S, 1315S/M, 1320S/H/M, 1325S/H/M Non-clog) are provided in the document, with weights varying based on cable length (10m or 20m) and installation kit. For example, a 1305S-50W.251.S66... pump weighs 35 kg with a 10m cable and 38 kg with a 20m cable. See the official PDF for detailed dimensional drawings and specific model weights.
Electrical
The motors are designed for reliable operation in submersible applications and feature F-class insulation or better, allowing for continuous running without overheating. Overall specifications for the 1300 Non-clog Series:
- Motor power: up to 18 kW
- Motor protection: IP68
- Insulation class: 155°C (F)
- Power supply: 230V single-phase, 400V three-phase, 50 Hz
- Voltage variation:
- Continuous running: max ±5%
- Intermittent running: max ±10%
- Voltage imbalance between phases: max 2%
- Motor thermal protection: Included in all models, opening temperature 125°C, class 155°C (F)
- Standard cable (10 m):
- Direct-on-line start: SUBCAB® 4G1,5+2x1,5
- Y/D start: SUBCAB® 7G2,5+2x1,5
Optional electrical features include:
- 20 m cable
- Different voltages: 380V and 415V for three-phase versions, 220V and 240V for single-phase versions.
Electrical data tables are present in the official PDF but are unreadable in the extracted text. See the official PDF for exact tabulated values.
Installation / Accessories
The 1300 series is designed for flexibility in installation, starting with a bare pump and adding the appropriate kit:
- Wet-well kit (W): For permanent fixed submerged installations with twin guide bars on a discharge connection. Access for inspection or maintenance is quick and easy by lifting the pump with a chain. The motor is cooled by the surrounding liquid, requiring a minimum liquid level.
- Free-standing kit (H or T): Ideal for portability.
- Type T (Threaded connection): Portable submerged installation with pump stand and delivery connection.
- Type H (Hose connection): Portable submerged installation with pump stand and hose connection. The motor is cooled by the surrounding liquid, requiring a minimum liquid level.
- Replacement kit (R): A simple kit to replace an old pump or upgrade to a larger model.
Available accessories include:
- Ball check valve
- Wastewater level regulators
- Command and control panels
- Lifting chains
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.