Product Identification

The Lowara e-SH Series consists of horizontal centrifugal electric pumps, designed according to EN 733. These are single-stage, end-suction electro-pumps with an axial flanged suction port, radial flanged discharge, and horizontal shaft.

Key features:

  • Construction Material: Fully made in AISI 316 stainless steel.
  • Motor Efficiency: Equipped with IE3 efficiency motors.
  • Ecodesign Compliance: ErP 2009/125/EC compliant, with a Minimum Efficiency Index (MEI) equal to or higher than 0.4.
  • Design: Back pull-out design allows for impeller, bracket, and motor extraction without disconnecting the pump body from piping.
  • Fluid Compatibility: Suitable for handling water as well as non-aggressive or moderately aggressive fluids.
  • Available Constructions:
    • Extended shaft (ESHE)
    • Stub shaft (ESHS)
    • Frame mounted (ESHF)
    • Frame mounted with spacer coupling (ESHC)
    • Bare shaft pump (ESH)

Operating Limits

  • Maximum Delivery:
    • Up to 240 m³/h for 2-pole range.
    • Up to 144 m³/h for 4-pole range.
  • Maximum Head:
    • Up to 110 m for 2-pole range.
    • Up to 27 m for 4-pole range.
  • Fluid Temperature Range:
    • Standard version (with FKM gaskets): -20 to +120 °C
    • Versions on request (with EPDM gaskets): -30 to +120 °C
  • Maximum Operating Pressure:
    • 12 bar @ 50 °C
    • 10.9 bar @ 120 °C
  • Hydraulic Performance: Compliant with ISO 9906:2012 Grade 3B.

Mechanical / Hydraulic

  • Discharge Ports: DN25 to DN80.
  • Connection Dimensions: According to EN 733 (except for ESH 25 models).
  • Rotation: Anti-clockwise when facing the pump’s suction port.
  • Counter-flanges: Pump does not include counter-flanges.
  • Mechanical Seals: Interchangeable mechanical seals with mounting dimensions according to EN 12756 and ISO 3069.
    • Standard: Ceramic/Carbon/FKM
    • Other types available: Ceramic/Carbon/EPDM, SiC/Carbon/FKM, SiC/Carbon/EPDM, SiC/SiC/FKM, SiC/SiC/EPDM.

Electrical

  • Motor Type: Squirrel cage in short circuit enclosed construction with external ventilation (TEFC).
  • Poles: 2-pole and 4-pole ranges.
  • Protection Degree:
    • IP55 as motor (EN 60034-5)
    • IPX5 as electro-pump (EN 60529)
  • Performance: According to EN 60034-1.
  • Efficiency Level: IE3 (for three-phase motors from 0.75 to 75 kW), according to EN 60034-30:2009 and EN 60034-30-1:2014.
  • Insulation Class: 155 (F).
  • Standard Voltage (50 Hz):
    • Single-phase: 1 x 220-240 V for power up to 2.2 kW.
    • Three-phase:
      • 3 x 220-240/380-415 V for power up to 3 kW.
      • 3 x 380-415/660-690 V for power above 3 kW.
  • Overload Protection:
    • Single-phase versions include built-in automatic reset overload protection.
    • Three-phase versions require user-provided overload protection.
  • PTC: Included as standard only for WEG motors (one per phase, 155°C).
  • Maximum Ambient Temperature: 40 °C.
  • Metric Cable Gland: According to EN 50262.

Models and Performance

The document provides detailed lists of models for both 2-pole and 4-pole configurations at 50 Hz, along with hydraulic performance ranges and motor specifications. See the official PDF for exact tabulated values.


Disclaimer: This summary is based solely on the extracted text and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.