| Type | Code No. | Power Consump. (kW) | Pressure max. (bar) | RPM max. (min⁻¹) | Output max. (l/min) | Water-Temp. max. (°C) | NPSH Required (mWs) |
|---|---|---|---|---|---|---|---|
| P76/210-200G | 00.6951 | 82,5 | 200 | 800 | 210,0 | 30 | 9,1 |
| P76/210-200GU* | - | 82,5 | 200 | 800 | 210,0 | 30 | - |
| P76/265-175G | 00.6952 | 90,0 | 175 | 800 | 264,0 | 30 | 9,3 |
| P76/265-175GU* | - | 90,0 | 175 | 800 | 264,0 | 30 | - |
| P76/320-140G | 00.6953 | 88,0 | 140 | 800 | 320,0 | 30 | 9,8 |
| P76/320-140GU* | - | 88,0 | 140 | 800 | 320,0 | 30 | - |
* "GU" models include gear boxes; different ratios are available on request.
Safety Guidelines:
- A safety valve must be installed in accordance with guidelines for liquid spraying units, set so that the admissible operating pressure cannot be exceeded by more than 10%.
- Pump operation without a safety valve, or any excess in temperature or speed limits, automatically voids the warranty.
Feed water
SPECK TRIPLEX Plunger Pumps are suitable for pumping clean water and other non-aggressive or abrasive media with a specific weight similar to water.
- Prior to pumping any other media, a check must be made to determine the suitability and resistance of the pumps (standard or special version), considering pump performance and temperature values.
- Particular care is required when pumping warm water, making absolutely sure that cavitation cannot occur.
Mechanical / hydraulic
General Specifications:
- Plunger diameter: 45 mm, 50 mm, or 55 mm (depending on model)
- Stroke: 58 mm
- Weight (approx.): 185 kg or 215 kg (depending on model)
Construction Characteristics:
- Crankcase: Solid sphero-cast iron, ensuring high stability and vibration dampening.
- Crankshaft: Features taper roller bearings and plain bearing con rod, all running in oil.
- Plunger: Solid ceramic.
- Sealing: Double plunger sealing.
- Gaskets: All gaskets are held in seal sleeves, ensuring precise centering and easy replacement.
- Optional reduction gear: Available with gear ratios for 1500 min⁻¹, 1800 min⁻¹, and 2200 min⁻¹ input RPM.
- Can be supplied with a solid shaft or hollow shaft (SAE-C Spline 14T 12/24DP).
- Includes a mounting flange for a hydraulic motor.
- Optional integrated gear oil cooling system: Recommended for power ratings >60 kW or continuous operation.
- Pumps are also available with a valve lifter.
Materials Used:
- Valve Casing: Nickel-plated sphero-cast-iron.
- Plunger: Solid ceramic.
- Valves: High-Grade Stainless Steel.
- Sleeves: Nitrile (NBR) with fabric reinforcing.
- Crankshaft: Drop-forged and case-hardened.
Installation Considerations:
- Even though SPECK-TRIPLEX P76 pumps run almost pulsation-free, a pressure accumulator may be necessary in some cases. This depends mainly on the unit's construction and overall operating conditions.
- The effect of a pressure accumulator can also be achieved by using flexible pressure lines.
- Using a pulsation damper adds considerably to the life of the seals and bearings.
Electrical
- Power consumption ranges from 82.5 kW to 90.0 kW, depending on the model.
- A general formula for calculating power is:
P (bar) x Q (l/min) = kW / 475
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official OEM PDF datasheet. Contractual data must always match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.