Datasheet summary
ACM-20 TDS
Engineering summary from PDF text extraction for ACM-20 TDS. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: AKUALYS ACM-20, ACM
- Diameter: 140 mm
- Body and Cap Material: U-PVC
- Nozzles: NPT1 - Victaulic
- Potting Material: Polyurethane
Membrane Specifications
- Material: Modified PVDF
- Membrane Type: Hollow Fiber UF
- Flow Direction: Outside to inside
- Fiber Outside/Inside Diameter: 1.4 / 0.8 mm
- Active Surface Area: 20 m²
- Nominal MWCO, Dextrane: ≤150,000 Dalton
- Nominal Pore Diameter: 30 nm
- Characteristics: High mechanical strength, chemical resistance, high permeability, long lifetime.
- Performance: Removes viruses, bacteria, and particles including colloids.
Mechanical / hydraulic
- Dimensions (mm):
- A: 1000±1
- B: 60±1
- C: 75±1
- D: 140±1
- Weight: 12 kg
Operating limits
- Operation Modes: Dead End / Crossflow
- Temperature: 1-40 °C
- pH: 2-11
- Filtrate Flux @25°C: 45-180 L/m²h
- Flow Capacity: 0.90-3.60 m³/h
- Feed Water Inlet Pressure @ 25°C: 2-3 bar (Instant Max. 5 bar)
- Transmembrane Pressure (TMP): 0.4 - 2 bar
Feed water
- Temperature: 25 °C (Max 40 °C)
- Particle Dimension: < 300 µ
- Turbidity: 50 NTU (Max 250 NTU)
- Oil and Grease: 0 % (Max 1 %)
- pH: 6-9
- Total Organic Carbon (TOC): < 10 mg/l (Max 30 mg/l)
- Total Suspended Solid (TSS): 50 mg/l (Max 80 mg/l)
- Chlorine: 0.4 mg/l (Instant Max. 150 mg/l)
Product water
- SDI: ≤2.5
- Turbidity: ≤0.2 NTU
Cleaning, Disinfection & Preservative Solution
- Cleaning Parameters:
- Backwash Pressure: Max. 2.5 bar
- Air Flowrate: 1 Nm³/h
- Chemically Enhanced Backwash (CEB) Chemicals:
- Sodium Hypochlorite (NaOCl): 1000 mg/l
- Sodium Hydroxide (NaOH): 500 mg/l
- Hydrochloric Acid (HCl): 1000 mg/l
- Citric Acid: 1-2 %
- Clean-in-Place (CIP):
- Frequency: When Current Process TMP ≥ Initial TMP + 0.9 bar
- Operation Duration: 2 hours
- Chemical Cleaning Solutions (depend on pollutant):
- 0.1 % NaOH + 0.2 % NaOCl
- 0.2 % HCl, 2 % Citric Acid
- Cleaning Flowrate per Module: 1-2 m³/h
- Cleaning of Preservative Solution:
- Preservative Solution Composition: Water/glycerol/sodium metabisulfite.
- Procedure: Drain module slowly with feed water; minimum 4 hours duration.
- Required Feed Water Volume: At least 3.6 m³.
- Cleaning - Disinfection:
- Chemical: 100 ppm sodium hypochlorite solution.
- Procedure: Circulate for 10 minutes, then soak for 1 hour. Drain until the filtrate line is free from chlorine.
Process Steps
The datasheet outlines three main process steps with specific valve positions:
- Production:
- Forward Flush: Rinsing with feed water.
- Filtration: Production phase.
- Backwash:
- Drain: Module drainage.
- Air Scourge: Membrane scouring with air.
- Backwash-Bottom: Rinsing with permeate water (top to bottom flow).
- Backwash-Top: Rinsing with permeate water.
- CEB (Caustic/Chlor/Acid):
- Drain: Module drainage.
- Air Scourge: Membrane scouring with air.
- Backwash-Bottom: Rinsing with permeate water and chemical (top to bottom flow).
- Backwash-Top: Rinsing with permeate water and chemical.
- Soak: Membranes are soaked with all valves closed.
- Drain: Module drainage.
- Air Scourge: Membrane scouring with air.
- Backwash-Bottom: Rinsing with permeate water (top to bottom flow).
- Backwash-Top: Rinsing with permeate water.
- Forward Flush: Rinsing with feed water.
Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions from the official PDF. Contractual data should always match the OEM PDF revision used on the project.
Official datasheet (PDF)