Back to Aquaporin-Inside Membranes
Aquaporin logo

Datasheet summary

Aquaporin Inside Clear Ultra 4040

Engineering summary from PDF text extraction for Aquaporin Inside Clear Ultra 4040. Verify every value with the OEM datasheet.

Summary

Product Identification

The Aquaporin Inside® CLEAR series features biomimetic brackish water reverse osmosis products. The CLEAR Ultra products are ultra low-energy reverse osmosis elements designed to maximize energy savings in water production and reuse. They are suitable for drinking water purification, light industrial applications, and compact commercial solutions.

Product Features:

  • Best-in-class permeate flow rate
  • Deliver great permeate quality at ultra-low pressure
  • Reliable performance in long-term operation

Product Water

Performance Specifications The stated product performances are tested at 25 °C (77 °F), 15% recovery, pH 7–8. Permeate flow rates and rejections are stated after a minimum of 60 minutes of operation. Flow rates for individual elements may vary but will be no more than 15% below the value shown.

Product NameItem No.Element TypeSpacer Thickness (mil)Permeate Flow Rate (GPD)Stabilized Salt RejectionMinimum RejectionFeed WaterPressure (psi / bar)
Aquaporin Inside® CLEAR Ultra 404040111Wet, fiberglass342,60099.0%98.0%500 ppm NaCl100 / 6.9
Aquaporin Inside® CLEAR Ultra 4040XL40112Wet, fiberglass273,10099.0%98.0%500 ppm NaCl100 / 6.9
Aquaporin Inside® CLEAR Ultra 8040-40040131Wet, fiberglass3412,50099.0%98.0%500 ppm NaCl100 / 6.9
Aquaporin Inside® CLEAR Ultra 8040-44040130Wet, fiberglass2713,50099.0%98.0%500 ppm NaCl100 / 6.9

Operating Limits

  • Maximum operating pressure:
    • 4040 series: 300 psi (20.7 bar)
    • 8040 series: 600 psi (41.4 bar)
  • Maximum feed flow rate:
    • 4040 series: 16 gpm (3.6 m³/h)
    • 8040 series: 75 gpm (17 m³/h)
  • Maximum operating temperature: 45 °C (113 °F)
  • pH range (operation): 3–10
  • pH range (short-term cleaning, 25 °C / 77 °F): 1–12
  • Maximum pressure drop: 15 psi (1 bar) per element; 60 psi (4 bar) per vessel (min. 4 elements)

Feed Water

  • Maximum feed water SDI: 5 (15 min)
  • Maximum feed water turbidity: 1 NTU
  • Free chlorine tolerance: < 0.1 ppm (Note: The presence of free chlorine and other oxidizing agents can cause premature membrane failure. Oxidation damage is not covered under warranty.)

Mechanical / Hydraulic

Element Dimensions (inches / millimeters)

  • Aquaporin Inside® CLEAR Ultra 4040 series:
    • Length (A): 40.0 / 1016.0
    • Brine Seal Diameter (B): 1.05 / 26.7
    • Permeate Tube Diameter (C): 0.75 / 19.1
    • Element Diameter (D): 3.95 / 100.3
    • Fits standard 4 inch inner diameter pressure vessels.
  • Aquaporin Inside® CLEAR Ultra 8040 series:
    • Length (A): 40.0 / 1016.0
    • Brine Seal Diameter (B): 1.125 / 28.6
    • Element Diameter (C): 7.9 / 200
    • Fits standard 8 inch inner diameter pressure vessels.

Additional Information

  • Permeate from the first hour of operation should be discarded and not used for consumption.
  • Keep elements moist at all times after initial wetting.
  • For detailed information on handling, storage, preservation, and optimal operation, refer to the "Handling, Storage, and Preservation of Industrial Aquaporin Inside® RO Membrane Elements" guide and the "Industrial Aquaporin Inside® RO Membrane Element User Manual".
  • For membrane cleaning procedures, refer to the "Membrane Clean-in-Place (CIP) Guide for Industrial Aquaporin Inside® RO Membrane Elements".
  • This product may be subject to drinking water application restrictions in some countries.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.