AXEON Water Technologies manufactures membrane systems, elements, housings, and chemicals. The membrane elements utilize industry-leading film technology, are shipped dry for indefinite shelf life, and are individually vacuum tested. AXEON products are stated to be Made in the U.S.A.

Residential TF elements are tested and certified by NSF International against NSF/ANSI Standard 58 for material requirements only.

AXEON TF-Series Residential Membrane Elements (RO and Nanofiltration)

Product Identification

  • AXEON TF-Series Reverse Osmosis Polyamide-Thin Film Composite Membranes.
  • AXEON NF Nanofiltration Membranes.
  • TF elements are NSF 58 listed and approved for material requirements only.

Operating Limits

  • Maximum Operating Temperature: 113°F (45°C)
  • Maximum Operating Pressure: 150 psi (10 bar)
  • Maximum Feed Flow Rate: 2 gpm (7.6 lpm)
  • pH Range, Continuous Operation: 2 – 11
  • Maximum temperature for continuous operations above pH10: 95°F (35°C)
  • Maximum Feed Silt Density Index (SDI): 5
  • Chlorine Tolerance: 0 ppm

Feed Water

Test parameters for performance specifications:

  • Feed Water: 550 TDS Filtered (5 Micron), De-Chlorinated, Municipal Feed Water
  • Temperature: 77°F
  • Permeate Recovery: 15%
  • pH Range: 6.5 - 7.0

Product Water

  • Nominal Salt Rejection:
    • TF: 98.0%
    • NF: 80.0 – 90.0%
  • Minimum salt rejection (for TF): 96%
  • Permeate flow for individual elements may vary ± 20%.

Mechanical / Hydraulic

  • Fits a standard 2” x 12” residential membrane housing.
  • Maximum Pressure drop for each element: 10 psi.
  • Dimensions are consistent for all TF-1812 series elements:
    • A: 11.74 inches (298.2 mm)
    • B: 10.00 inches (254 mm)
    • C: 0.86 inches (21.84 mm)
    • D: 0.88 inches (22.35 mm)
    • E: 1.77 inches (45.08 mm)

AXEON HF1-Series Commercial Membrane Elements (Low Energy RO)

Product Identification

  • AXEON Low Energy HF1-Series Reverse Osmosis Membranes.
  • Membrane Type: Polyamide Thin-Film Composite.
  • Available in all standard commercial sizes, feature a protective ABS shell.

Operating Limits

  • Maximum Operating Temperature: 113°F (45°C)
  • Maximum Operating Pressure: 600 psi (41 bar)
  • pH Range, Continuous Operation: 2 – 11
  • Maximum temperature for continuous operations above pH10: 95°F (35°C)
  • pH Range, Short Term Cleaning (30 Min.): 1 – 13
  • Maximum Feed Silt Density Index (SDI): 5
  • Chlorine Tolerance: 0 ppm

Feed Water

Test parameters for performance specifications:

  • Feed Water: 550 TDS Filtered (5 Micron), De-Chlorinated, Municipal Feed Water
  • Temperature: 77°F
  • Permeate Recovery: 15%
  • pH Range: 6.5 - 7.0

Product Water

  • Nominal Salt Rejection: 99.0%
  • Minimum salt rejection: 96%
  • Permeate flow for individual elements may vary ± 20%.

Mechanical / Hydraulic

  • Maximum Pressure drop for each element: 15 psi.
  • Dimensions (inch (mm)) and Performance Data (Applied Pressure, Permeate Flow Rate, Nominal Salt Rejection): See the official PDF for exact tabulated values for individual part numbers (200374 to 200379).

AXEON HF4-Series Commercial Membrane Elements (Extra Low Energy RO)

Product Identification

  • AXEON Extra Low Energy HF4-Series Reverse Osmosis Membranes.
  • Membrane Type: Polyamide Thin-Film Composite.
  • Available in all standard commercial sizes, feature a protective ABS shell.

Operating Limits

  • Maximum Operating Temperature: 113°F (45°C)
  • Maximum Operating Pressure: 600 psi (41 bar)
  • pH Range, Continuous Operation: 2 – 11
  • Maximum temperature for continuous operations above pH10: 95°F (35°C)
  • pH Range, Short Term Cleaning (30 Min.): 1 – 13
  • Maximum Feed Silt Density Index: 5
  • Chlorine Tolerance: 0 ppm

Feed Water

Test parameters for performance specifications:

  • Feed Water: 550 TDS Filtered (5 Micron), De-Chlorinated, Municipal Feed Water
  • Temperature: 77°F
  • Permeate Recovery: 15%
  • pH Range: 6.5 - 7.0

Product Water

  • Nominal Salt Rejection: 99.0%
  • Minimum salt rejection: 96%
  • Permeate flow for individual elements may vary ± 20%.

Mechanical / Hydraulic

  • Maximum Pressure drop for each element: 13 psi.
  • Dimensions (inch (mm)) and Performance Data (Applied Pressure, Permeate Flow Rate, Nominal Salt Rejection): See the official PDF for exact tabulated values for individual part numbers (200386 to 200391).

AXEON HF5-Series Commercial Membrane Elements (Ultra Low Energy RO)

Product Identification

  • AXEON Ultra Low Energy HF5-Series Reverse Osmosis Membranes.
  • Membrane Type: Polyamide Thin-Film Composite.
  • Available in all standard 4-inch commercial sizes, feature a protective tape wound exterior.
  • Noted as the only elements on the market that operate at 80 psi.

Operating Limits

  • Maximum Operating Temperature: 113°F (45°C)
  • Maximum Operating Pressure: 400 psi (27.58 bar)
  • pH Range, Continuous Operation: 2 – 11
  • Maximum temperature for continuous operations above pH10: 95°F (35°C)
  • pH Range, Short Term Cleaning (30 Min.): 1 – 13
  • Maximum Feed Silt Density Index: 5
  • Chlorine Tolerance: 0 ppm

Feed Water

Test parameters for performance specifications:

  • Feed Water: 550 TDS Filtered (5 Micron), De-Chlorinated, Municipal Feed Water
  • Temperature: 77°F
  • Permeate Recovery: 15%
  • pH Range: 6.5 - 7.0

Product Water

  • Nominal Salt Rejection: 98.5%
  • Minimum salt rejection: 96%
  • Permeate flow for individual elements may vary ± 20%.

Mechanical / Hydraulic

  • Maximum Pressure drop for each element: 13 psi.
  • Dimensions (inch (mm)) and Performance Data (Applied Pressure, Permeate Flow Rate, Nominal Salt Rejection): See the official PDF for exact tabulated values for individual part numbers (200392 to 200394).

AXEON HR3-Series Commercial Membrane Elements (High Rejection RO)

Product Identification

  • AXEON High Rejection HR3-Series Reverse Osmosis Membrane Elements.
  • Membrane Type: Polyamide Thin-Film Composite.
  • Available in all standard commercial sizes, feature a protective ABS shell.

Operating Limits

  • Maximum Operating Temperature: 113°F (45°C)
  • Maximum Operating Pressure: 600 psi (41 bar)
  • pH Range, Continuous Operation: 2 – 11
  • Maximum temperature for continuous operations above pH10: 95°F (35°C)
  • pH Range, Short Term Cleaning (30 Min.): 1 – 13
  • Maximum Feed Silt Density Index (SDI): 5
  • Chlorine Tolerance: 0 ppm

Feed Water

Test parameters for performance specifications:

  • Feed Water: 550 TDS Filtered (5 Micron), De-Chlorinated, Municipal Feed Water
  • Temperature: 77°F
  • Permeate Recovery: 15%
  • pH Range: 6.5 - 7.0

Product Water

  • Nominal Salt Rejection: 99.5%
  • Minimum salt rejection: 96%
  • Permeate flow for individual elements may vary ± 20%.

Mechanical / Hydraulic

  • Maximum Pressure drop for each element: 13 psi.
  • Dimensions (inch (mm)) and Performance Data (Applied Pressure, Permeate Flow Rate, Nominal Salt Rejection): See the official PDF for exact tabulated values for individual part numbers (200368 to 200373).

AXEON NF3-Series Commercial Membrane Elements (Nanofiltration)

Product Identification

  • AXEON NF3-Series Nanofiltration Membrane Elements.
  • Membrane Type: Polyamide Thin-Film Composite.
  • Available in all standard commercial sizes, feature a protective ABS shell.

Operating Limits

  • Maximum Operating Temperature: 113°F (45°C)
  • Maximum Operating Pressure: 600 psi (41 bar)
  • pH Range, Continuous Operation: 2 – 11
  • Maximum temperature for continuous operations above pH10: 95°F (35°C)
  • pH Range, Short Term Cleaning (30 Min.): 1 – 12
  • Maximum Feed Silt Density Index: 5
  • Chlorine Tolerance: 0 ppm

Feed Water

Test parameters for performance specifications:

  • Feed Water: 550 TDS Filtered (5 Micron), De-Chlorinated, Municipal Feed Water
  • Temperature: 77°F
  • Permeate Recovery: 15%
  • pH Range: 6.5 - 7.0

Product Water

  • Nominal Salt Rejection: 40.0 – 50.0%
  • Permeate flow for individual elements may vary ± 20%.

Mechanical / Hydraulic

  • Maximum Pressure drop for each element: 13 psi.
  • Dimensions (inch (mm)) and Performance Data (Applied Pressure, Permeate Flow Rate, Nominal Salt Rejection): See the official PDF for exact tabulated values for individual part numbers (200401 to 200406).

AXEON NF4-Series Commercial Membrane Elements (Nanofiltration)

Product Identification

  • AXEON NF4-Series Nanofiltration Membrane Elements.
  • Membrane Type: Polyamide Thin-Film Composite.
  • Available in all standard commercial sizes, feature a protective ABS shell.

Operating Limits

  • Maximum Operating Temperature: 113°F (45°C)
  • Maximum Operating Pressure: 600 psi (41 bar)
  • pH Range, Continuous Operation: 2 – 11
  • Maximum temperature for continuous operations above pH10: 95°F (35°C)
  • pH Range, Short Term Cleaning (30 Min.): 1 – 12
  • Maximum Feed Silt Density Index: 5
  • Chlorine Tolerance: 0 ppm

Feed Water

Test parameters for performance specifications:

  • Feed Water: 550 TDS Filtered (5 Micron), De-Chlorinated, Municipal Feed Water
  • Temperature: 77°F
  • Permeate Recovery: 15%
  • pH Range: 6.5 - 7.0

Product Water

  • Nominal Salt Rejection: 80.0 – 90.0%
  • Permeate flow for individual elements may vary ± 20%.

Mechanical / Hydraulic

  • Maximum Pressure drop for each element: 13 psi.
  • Dimensions (inch (mm)) and Performance Data (Applied Pressure, Permeate Flow Rate, Nominal Salt Rejection): See the official PDF for exact tabulated values for individual part numbers (200407 to 200412).

AXEON PVC Membrane Housings

Product Identification

  • AXEON PVC Membrane Housings.
  • Materials: NSF Approved PVC Material, NSF Approved GTX Material, NSF Approved EPR O-Rings.

Operating Limits

  • Maximum Operating Pressure: 225 psi @ 73°F (22°C)
  • Maximum Operating Temperature: 110°F (43°C)
  • Minimum Operating Temperature: 35°F (1°C)

Mechanical / Hydraulic

  • Features:
    • PVC and GTX® material with side port connections.
    • Design requires no tools for assembly.
    • Removable end plug for ease of installation and maintenance.
    • Locking wedge for security.
    • Double o-ring permeate seals.
    • Individually inspected and sanitized.
    • Fits all standard size membrane elements.
    • "A" Housings accommodate female flush cut elements.
    • Quadra Port (4 open ports) Housings allow for ease of plumbing.
    • 180° Rotated Port Housings available.
    • Custom sizing available.
    • Adapters and interconnectors available.
  • Approximate Dimensions (inches) and Port Sizes: See the official PDF for exact tabulated values for individual part numbers (200518 to 200552), including number of membranes, permeate port size, concentrate port size, and feed port size.

AXEON Stainless Steel (SS) Membrane Housings

Product Identification

  • AXEON Stainless Steel (SS) Membrane Housings.
  • Features the True-Clamp™ Integrated Clamping System.
  • 304L corrosion resistant stainless steel end entry connections.
  • Materials of Construction:
    • End Plug: Nylon
    • Clamp: 304 SS
    • End Plug Screws: 304 SS
    • O-Ring: Buna-N
    • Housing Body: 304L SS (1.80 mm Thick)

Operating Limits

  • Maximum Operating Pressure: 250 psi (17 bar)
  • Minimum Operating Temperature: 35°F (1°C)
  • Maximum Operating Temperature: 120°F (48°C)

Mechanical / Hydraulic

  • Accommodate any make of 2.5-inch or 4-inch nominal diameter spiral wound elements with a 3⁄4” diameter male product tube.
  • Seamless Housing Body (1.80 mm Thick).
  • End Entry Single Piece Nylon End Plugs.
  • Buna-N Double O-Rings for Sealing Integrity.
  • Accommodate All Standard Sized Membrane Elements.
  • Adapters, interconnectors and mounting clamps available.
  • Dimensions and Connections (FNPT): See the official PDF for exact tabulated values for individual part numbers (202919 to 202924), including number of membranes, diameter, length, and feed, permeate, and concentrate port sizes.

Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions. For contractual data, please refer to the official OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.