Datasheet summary
HF5
Engineering summary from PDF text extraction for HF5. Verify every value with the OEM datasheet.
Summary
Product identification
AXEON HF5 – Series Membrane Elements are manufactured using leading membrane film technology, offering reliability, high performance, and consistent results. These elements provide increased production, high rejection rates, and ultra-low energy consumption by operating at low applied pressures.
Key features:
- Ultra Low Energy with High Flow Rates
- Available in all industry standard 2.5-inch and 4-inch commercial sizes
- Feature a tape-wound exterior
- Suitable for countering negative effects of cold water temperatures on reverse osmosis production
- 100% vacuum integrity tested; individually wet tested available
- Shipped dry for indefinite shelf life, easier handling, and lighter shipping weight
- Membrane Type: Polyamide Thin – Film Composite
Operating limits
- Maximum Operating Temperature: 113 °F / 45 °C
- Maximum Operating Pressure: 400 psi / 27.58 bar
- pH Range, Continuous Operation: 2 – 11
- Note: Maximum temperature for continuous operations above pH 10 is 95 °F / 35 °C.
- pH Range, Short Term Cleaning (30 Min.): 1 – 13
- Maximum Feed Silt Density Index (SDI): 5
- Chlorine / Chloramine Tolerance: 0 ppm
- Maximum Feed Flow Rate:
- 2.5” elements: 6 gpm
- 4.0” elements: 14 gpm
Product water
The following table outlines the performance specifications, evaluated at an applied pressure of 80 psi / 5.52 bar.
| Part Number | Description | Permeate Flow Rate (gpd / m³/d) | Nominal Salt Rejection (%) |
|---|---|---|---|
| 208125 | HF5 – 2514 | 225 / 0.85 | 98.50 |
| 208083 | HF5 – 2521 | 400 / 1.51 | 98.50 |
| 208084 | HF5 – 2540 | 850 / 3.22 | 98.50 |
| 200392 | HF5 – 4014 | 600 / 2.27 | 98.50 |
| 200393 | HF5 – 4021 | 1000 / 3.79 | 98.50 |
| 200394 | HF5 – 4040 | 2500 / 9.46 | 98.50 |
- Warranty Evaluation Test Conditions: Permeate flow and salt rejection based on: 550 ppm, filtered and dechlorinated municipal tap water, 77 °F / 25 °C, 15% recovery, and the specified operating pressure (80 psi / 5.52 bar).
- Minimum salt rejection for warranty is 96%. Permeate flows for warranty evaluation may vary +/-20%.
- Maximum pressure drop during warranty evaluation is 13 psig / 0.9 bar.
Mechanical / hydraulic
- All 2514, 2521, and 2540 elements fit nominal 2.50” I.D. membrane housings.
- All 4014, 4021, and 4040 elements fit nominal 4.00” I.D. membrane housings.
Dimensions (inch / mm):
| Description | A | B | C | D |
|---|---|---|---|---|
| HF5 – 2514 | 14 / 355.60 | 1.1 / 27.94 | 0.75 / 19.05 | 2.40 / 60.96 |
| HF5 – 2521 | 21 / 533.40 | 1.1 / 27.94 | 0.75 / 19.05 | 2.40 / 60.96 |
| HF5 – 2540 | 40 / 1016.00 | 1.1 / 27.94 | 0.75 / 19.05 | 2.40 / 60.96 |
| HF5 – 4014 | 14 / 355.60 | 1.1 / 27.94 | 0.75 / 19.05 | 3.95 / 100.30 |
| HF5 – 4021 | 21 / 533.40 | 1.1 / 27.94 | 0.75 / 19.05 | 3.95 / 100.30 |
| HF5 – 4040 | 40 / 1016.00 | 1.1 / 27.94 | 0.75 / 19.05 | 3.95 / 100.30 |
System Startup Guidelines:
- Feed pressure should be increased gradually over a 30 – 60 second timeframe.
- Cross-flow velocity at the set operating point should be achieved gradually over 15 – 20 seconds.
- Permeate obtained from the first hour of operation should be discarded.
- Maximum pressure drop across an entire pressure vessel (housing) is 30 psi / 2.1 bar.
- Avoid static permeate-side backpressure at all times.
General Cautions:
- The presence of free chlorine, chloramines, and other oxidizing agents will cause premature membrane failure. Remove all oxidizing agents by pretreatment.
- Keep elements moist at all times after initial wetting.
- To prevent biological growth during prolonged system shutdowns, immerse membrane elements in a preservative solution. Rinse out the preservative before use.
- The warranty will be null and void if operating limits and guidelines are not strictly followed, or due to the effects of incompatible chemicals and lubricants on elements.
- These membranes may be subject to drinking water application restrictions in some countries; verify application status before use and sale.
- Use of this product does not guarantee the removal of cysts and pathogens from water; effective reduction depends on complete system design, operation, and maintenance.
Disclaimer