Back to Axeon Membranes
Axeon logo

Datasheet summary

Compact Systems

Engineering summary from PDF text extraction for Compact Systems. Verify every value with the OEM datasheet.

Summary

AXEON Water Treatment Systems

AXEON offers a range of engineered water treatment solutions designed for maximum performance and minimal maintenance, suitable for residential, commercial, industrial, and specialty applications. All systems comply with industry standards and specifications.

AXEON Timer Water Softeners

These systems utilize advanced 8% cross-link ion exchange resin technology to effectively reduce hardness and iron. Regeneration occurs on a fixed schedule, involving periodic backwashing with a salt or potassium solution to remove accumulated hardness ions.

Standard Features

  • Fleck® Control Valve with:
    • Easy to Program SXT Electronics
    • Pre-Treat Lockout Contacts
    • 48 Hour Power Backup
    • Day-of-the-Week Controls
    • Regeneration Can Be Triggered Immediately
  • Structural® Heavy Duty Fiberglass Tank
  • Heavy Duty Riser Pipe with Upper and Lower Screens
  • 8% Cross-Link Ion Exchange Resin
  • Brine Tank with Float Assembly and Salt Grid

Options and Upgrades

  • Yokes and Bypass Valves
  • Various Sizes and Types of Connectors
  • Stainless Steel Jackets

Electrical

Systems are available in 110V and 220V configurations.

Mechanical / Hydraulic

Specifications for these systems include:

  • DLFC: 3 to 15
  • Connections: 3/4” MNPT, 1” MNPT, 1.5” FNPT
  • Approximate GPG Capacity: 30,000 to 300,000
  • Tank Size: Various dimensions, e.g., 9 x 48, 10 x 54, 12 x 52, 13 x 54, 14 x 65, 16 x 65, 21 x 62, 24 x 60, 24 x 72
  • Cubic Feet: 1 to 10
  • Tank Quantity: 1
  • Brine Tank Size: 18 x 33, 18 x 40, 24 x 40, 24 x 54
  • Backwash Rate: 3.0 gpm to 15.0 gpm
  • Recommended Service Flow: 1.3–8.0 gpm to 15.0–52.0 gpm
  • Estimated Peak Flow: 10.0 gpm to 52.0 gpm
  • Shipping Weight: 110 lbs. to 925 lbs.
  • System Assembled: Assembled or Non-Assembled

See the official PDF for exact tabulated values for each model.

AXEON Meter Water Softeners

These systems utilize advanced 10% cross-link ion exchange resin technology to reduce hardness and iron. Regeneration is based on measured gallon flow-through. Periodic backwashing with a salt or potassium solution is required.

Standard Features

  • Fleck® Control Valve with:
    • Easy to Program SXT Electronics
    • Pre-Treat Lockout Contacts
    • 48 Hour Power Backup
    • Day-of-the-Week Controls
    • Regeneration Can Be Triggered Immediately
  • Structural® Heavy Duty Fiberglass Tank
  • Heavy Duty Riser Pipe with Upper and Lower Screens
  • 10% Cross-Link Ion Exchange Resin
  • Brine Tank with Float Assembly and Salt Grid

Options and Upgrades

  • Yokes and Bypass Valves
  • Various Sizes and Types of Connectors
  • Stainless Steel Jackets

Electrical

Systems are available in 110V and 220V configurations.

Mechanical / Hydraulic

Specifications for these systems include:

  • DLFC: 3 to 15
  • Connections: ¾” MNPT, 1” MNPT, 1.5” FNPT
  • Approximate GPG Capacity: 30,000 to 300,000
  • Tank Size: Various dimensions, e.g., 9 x 48, 10 x 54, 12 x 52, 13 x 54, 14 x 65, 16 x 65, 21 x 62, 24 x 60, 24 x 72
  • Cubic Feet: 1 to 10
  • Tank Quantity: 1
  • Brine Tank Size: 18 x 33, 18 x 40, 24 x 40, 24 x 54
  • Backwash Rate: 3.0 gpm to 15.0 gpm
  • Recommended Service Flow: 1.3–8.0 gpm to 15.0–52.0 gpm
  • Estimated Peak Flow: 10.0 gpm to 52.0 gpm
  • Shipping Weight: 110 lbs. to 925 lbs.
  • System Assembled: Assembled or Non-Assembled

See the official PDF for exact tabulated values for each model.

AXEON Meter Twin Water Softeners

These systems provide a continuous, uninterrupted supply of softened water by reducing hardness and iron using 8% cross-link ion exchange resin technology. Regeneration is based on measured gallon flow-through, and periodic backwashing with a salt or potassium solution is required.

Standard Features

  • Fleck® 9100SXT Control Valve with:
    • Easy to Program SXT Electronics
    • Pre-Treat Lockout Contacts
    • 48 Hour Power Backup
    • Day-of-the-Week Controls
    • Regeneration Can Be Triggered Immediately
  • Structural® Heavy Duty Fiberglass Tank
  • Heavy Duty Riser Pipe with Upper and Lower Screens
  • 8% Cross-Link Ion Exchange Resin
  • Brine Tank with Float Assembly and Salt Grid

Options and Upgrades

  • Yokes and Bypass Valves
  • Various Sizes and Types of Connectors
  • Stainless Steel Jackets

Electrical

Systems are available in 110V and 220V configurations.

Mechanical / Hydraulic

Specifications for these systems include:

  • DLFC: 3 to 7
  • Connections: 3/4” MNPT, 1” MNPT
  • Approximate GPG Capacity: 60,000 to 240,000
  • Tank Size: Various dimensions, e.g., 9 x 48, 10 x 54, 12 x 52, 13 x 54, 14 x 65, 16 x 65
  • Cubic Feet: 2 to 8
  • Tank Quantity: 2
  • Brine Tank Size: 18 x 40, 24 x 40
  • Backwash Rate: 3.0 gpm to 7.0 gpm
  • Recommended Service Flow: 1.3–8.0 gpm to 4.2–18.0 gpm
  • Estimated Peak Flow: 13.0 gpm to 15.0 gpm
  • Shipping Weight: 220 lbs. to 640 lbs.
  • System Assembled: Assembled or Non-Assembled

See the official PDF for exact tabulated values for each model.

AXEON Carbon Systems (Fleck Valve)

These systems use advanced activated carbon filtration technology, featuring Granulated Activated Coconut Carbon (GACC) that is acid washed and NSF 61 Certified. They are effective in reducing chlorine, unpleasant tastes and odors, suspended particles, and volatile organic compounds. Periodic backwashing is required.

Standard Features

  • Fleck® Control Valve with:
    • Easy to Program SXT Electronics
    • Pre-Treat Lockout Contacts
    • 48 Hour Power Backup
    • Day-of-the-Week Controls
    • Regeneration Can Be Triggered Immediately
  • Structural® Heavy Duty Fiberglass Tank
  • Heavy Duty Riser Pipe with Upper and Lower Screens
  • Granulated Activated Coconut Carbon (Carbon) Acid Washed NSF 61 Certified

Options and Upgrades

  • Yokes and Bypass Valves
  • Various Sizes and Types of Connectors
  • Stainless Steel Jackets

Electrical

Systems are available in 110V and 220V configurations.

Mechanical / Hydraulic

Specifications for these systems include:

  • DLFC: 4 to 35
  • Connections: 3/4” MNPT, 1” MNPT, 1.5” FNPT
  • Media: GACC Acid Washed
  • Tank Size: Various dimensions, e.g., 9 x 48, 10 x 54, 12 x 52, 13 x 54, 14 x 65, 16 x 65, 21 x 62, 24 x 60, 24 x 72
  • Cubic Feet: 1 to 10
  • Tank Quantity: 1
  • Backwash Rate: 3.5 gpm to 35.0 gpm
  • Recommended Service Flow: 1.3–3.0 gpm to 10.0–30.0 gpm
  • Estimated Peak Flow: 10.0 gpm to 52.0 gpm
  • Shipping Weight: 90 lbs. to 635 lbs.
  • System Assembled: Assembled or Non-Assembled

See the official PDF for exact tabulated values for each model.

AXEON Zeolite Systems

These systems employ advanced media filtration technology using NSF 61 Certified Zeolite Media. They are effective in reducing sediments and provide higher service flow rates and longer filter runs compared to equivalent media filters. Periodic backwashing with clean water is required.

Standard Features

  • Fleck® Control Valve with:
    • Easy to Program SXT Electronics
    • Pre-Treat Lockout Contacts
    • 48 Hour Power Backup
    • Day-of-the-Week Controls
    • Regeneration Can Be Triggered Immediately
  • Structural® Heavy Duty Fiberglass Tank
  • Heavy Duty Riser Pipe with Upper and Lower Screens
  • Zeolite Media NSF 61 Certified

Options and Upgrades

  • Yokes and Bypass Valves
  • Various Sizes and Types of Connectors
  • Stainless Steel Jackets

Electrical

Systems are available in 110V and 220V configurations.

Mechanical / Hydraulic

Specifications for these systems include:

  • DLFC: 7 to 45
  • Connections: 3/4” MNPT, 1” MNPT, 1.5” FNPT
  • Media: Zeolite
  • Tank Size: Various dimensions, e.g., 9 x 48, 10 x 54, 12 x 52, 13 x 54, 14 x 65, 16 x 65, 21 x 62, 24 x 60, 24 x 72
  • Cubic Feet: 1 to 10
  • Tank Quantity: 1
  • Backwash Rate: 7.0 gpm to 45.0 gpm
  • Recommended Service Flow: 1.3–3.0 gpm to 10.0–47.0 gpm
  • Estimated Peak Flow: 10.0 gpm to 47.0 gpm
  • Shipping Weight: 90 lbs. to 635 lbs.
  • System Assembled: Assembled or Non-Assembled

See the official PDF for exact tabulated values for each model.

AXEON Filox Systems

These systems provide advanced iron and hydrogen sulfide removal using NSF 61 Certified Filox Media. Periodic backwashing is required to dispose of accumulated contaminants.

Standard Features

  • Fleck® 7000SXT Control Valve with:
    • Easy to Program SXT Electronics
    • Pre-Treat Lockout Contacts
    • 48 Hour Power Backup
    • Day-of-the-Week Controls
    • Regeneration Can Be Triggered Immediately
  • Structural® Heavy Duty Fiberglass Tank
  • Heavy Duty Riser Pipe with Upper and Lower Screens
  • Filox Media NSF 61 Certified

Options and Upgrades

  • Yokes and Bypass Valves
  • Various Sizes and Types of Connectors
  • Stainless Steel Jackets

Electrical

Systems are available in 110V and 220V configurations.

Mechanical / Hydraulic

Specifications for these systems include:

  • DLFC: 12 to 25
  • Connections: 3/4” MNPT, 1” MNPT
  • Media: Filox
  • Tank Size: Various dimensions, e.g., 9 x 48, 10 x 54, 12 x 52, 13 x 54, 14 x 65
  • Cubic Feet: 1 to 3
  • Tank Quantity: 1
  • Backwash Rate: 10.0 gpm to 25.0 gpm
  • Recommended Service Flow: 6.0 gpm to 18.0 gpm
  • Estimated Peak Flow: 14.0 gpm to 20.0 gpm
  • Shipping Weight: 142 lbs. to 425 lbs.
  • System Assembled: Assembled

See the official PDF for exact tabulated values for each model.

AXEON Activated Carbon Systems (Clack Valve)

These systems feature advanced activated coconut carbon filtration technology. The GACC media is acid washed to reduce carbon fines and is NSF/ANSI Certified, effective in reducing chlorine, unpleasant tastes, and odors.

Standard Features

  • Clack 1191 In and Out Valve
  • Non-Corrosive UV-Resistant Valve Body
  • Structural® Heavy Duty Fiberglass Tank
  • Heavy Duty Riser Pipe and Lower Screen
  • Granulated Activated Coconut Carbon (GACC) Acid Washed NSF 61 Certified

Options and Upgrades

  • 90° Extensions and Bypass Valve
  • Various Connection Sizes Available
  • Stainless Steel Jacket

Mechanical / Hydraulic

Specifications for these systems include:

  • Connections: 1” MNPT
  • Media: GACC Acid Washed
  • Tank Size: Various dimensions, e.g., 9 x 48, 10 x 54, 12 x 52, 13 x 54, 14 x 65, 16 x 65
  • Cubic Feet: 1 to 4
  • Tank Quantity: 1
  • Recommended Service Flow: 4.0 gpm to 14.0 gpm
  • Estimated Peak Flow: 12.0 gpm to 20.0 gpm
  • Shipping Weight: 90 lbs. to 265 lbs.
  • System Assembled: Assembled or Non-Assembled

See the official PDF for exact tabulated values for each model.

AXEON Calcite Systems

These systems use an advanced calcite pH adjusting media to correct pH to reach a non-corrosive equilibrium. The media is gradually depleted and requires periodic replenishment, facilitated by quick disconnects on the In and Out valve.

Standard Features

  • Clack 1191 In and Out Valve
  • Non-Corrosive UV-Resistant Valve Body
  • Structural® Heavy Duty Fiberglass Tank
  • Heavy Duty Riser Pipe and Lower Screen

Options and Upgrades

  • 90° Extensions and Bypass Valve
  • Various Connection Sizes Available
  • Stainless Steel Jacket

Mechanical / Hydraulic

Specifications for these systems include:

  • Connections: 1” MNPT
  • Media: Calcite
  • Tank Size: Various dimensions, e.g., 9 x 48, 10 x 54, 12 x 52, 13 x 54, 14 x 65, 16 x 65
  • Cubic Feet: 1 to 4
  • Tank Quantity: 1
  • Recommended Service Flow: 1.3–2.6 gpm to 4.2–8.4 gpm
  • Estimated Peak Flow: 12.0 gpm to 20.0 gpm
  • Shipping Weight: 95 lbs. to 270 lbs.
  • System Assembled: Assembled or Non-Assembled

See the official PDF for exact tabulated values for each model.

AXEON Deionization Systems

These systems contain a high-quality resin mixture of Gel Poly Styrene crosslinked with DVB, capable of removing mineral ions such as cations (Na⁺, Ca²⁺, Fe²⁺, Cu²⁺) and anions (Cl⁻, Br⁻). The fiberglass tanks are ANSI/NSF STD 44 compliant.

Standard Features

  • Clack 1191 In and Out Valve
  • Non-Corrosive UV-Resistant Valve Body
  • Structural® Heavy Duty Fiberglass Tank
  • Heavy Duty Riser Pipe and Lower Screen
  • 60% Gel Poly Styrene crosslinked with 40% DVB

Options and Upgrades

  • 90° Extensions and Bypass Valve
  • Various Connection Sizes Available
  • Stainless Steel Jacket

Mechanical / Hydraulic

Specifications for these systems include:

  • Connections: 1” MNPT
  • Media: 60% Gel Poly Styrene crosslinked with 40% DVB
  • Tank Size: Various dimensions, e.g., 9 x 48, 10 x 54, 12 x 52, 13 x 54, 14 x 65, 16 x 65
  • Cubic Feet: 1 to 4
  • Tank Quantity: 1
  • Maximum Recommended Service Flow: 4.0 gpm to 14.0 gpm
  • Estimated Peak Flow: 12.0 gpm to 20.0 gpm
  • Shipping Weight: 110 lbs. to 320 lbs.
  • System Assembled: Assembled

See the official PDF for exact tabulated values for each model.


Disclaimer: This summary is based on the provided text extraction. It may not include all figures, footnotes, or the latest revisions present in the complete OEM PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.