CSM RE16040-BLF

Engineering summary from PDF text extraction for CSM RE16040-BLF. Verify every value with the OEM datasheet.

Summary

Product identification

This is a low-pressure grade Reverse Osmosis (RO) element designed for brackish water applications.

  • Model: RE16040-BLF
  • Membrane type: Thin-Film Composite
  • Membrane material: Polyamide (PA)
  • Element configuration: Spiral-Wound, FRP Wrapping

Performance specifications

  • Permeate flow rate: 46,000 GPD (174.1 m³/day)
  • Nominal salt rejection: 99.2%
  • Minimum salt rejection: 99.0%
  • Effective membrane area: 1,600 ft² (148.6 m²)

Performance is based on data taken after 30 minutes of operation at the following test conditions:

  • NaCl solution: 500 mg/L
  • Applied pressure: 100 psig (0.7 MPa)
  • Recovery: 15%
  • Temperature: 77 °F (25 °C)
  • pH: 6.5–7.0

Mechanical / hydraulic

  • Dimensions (Model RE16040-BLF):
    • A: 40.0 inch (1,016 mm)
    • B: 16.0 inch (402 mm)
    • C: 3.0 inch (77 mm)
  • Weight: 60 kg
  • Fit: Nominal 16.0 inch (402 mm) I.D. pressure vessels
  • Each membrane element is supplied with one interconnector (coupler) and five o-rings.

Operating limits

  • Max. Pressure Drop / Element: 15 psi (0.1 MPa)
  • Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
  • Max. Operating Pressure: 600 psi (4.14 MPa)
  • Max. Feed Flow Rate: 252 gpm (57.2 m³/hr)
  • Min. Concentrate Flow Rate: 64 gpm (14.5 m³/hr)
  • Max. Operating Temperature: 113 °F (45 °C)
  • Operating pH Range: 2.0–11.0
  • CIP pH Range: 1.0–13.0

Feed water

  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0
  • Max. Chlorine Concentration: < 0.1 mg/L

Chemical saturation limits (using antiscalants)

  • Langlier Saturation Index (LSI): <+1.5
  • Stiff and Davis Saturation Index (SDSI): <+0.5
  • CaSO₄: 230% saturation
  • SrSO₄: 800% saturation
  • BaSO₄: 6,000% saturation
  • SiO₂: 100% saturation

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.